Cargando…
Dose Prescription Methods in Stereotactic Body Radiotherapy for Small Peripheral Lung Tumors: Approaches Based on the Gross Tumor Volume Are Superior to Prescribing a Dose That Covers 95% of the Planning Target Volume
BACKGROUND AND PURPOSE: We aimed to validate the usefulness of prescriptions based on gross tumor volume for stereotactic body radiotherapy for small peripheral lung tumors. MATERIALS AND METHODS: Radiotherapy treatment planning data of 50 patients with small peripheral lung tumors (adenocarcinoma:...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720311/ https://www.ncbi.nlm.nih.gov/pubmed/33272112 http://dx.doi.org/10.1177/1533033820974030 |
Sumario: | BACKGROUND AND PURPOSE: We aimed to validate the usefulness of prescriptions based on gross tumor volume for stereotactic body radiotherapy for small peripheral lung tumors. MATERIALS AND METHODS: Radiotherapy treatment planning data of 50 patients with small peripheral lung tumors (adenocarcinoma: 24, squamous cell carcinoma: 10, other: 1, unknown: 15) receiving breath-hold computed tomography-guided stereotactic body radiotherapy at our institution during 2013–2016 were analyzed. For each case, 3 dose prescription methods were applied: one based on 95% (PTVD(95%)) of the planning target volume, one based on 50% of the gross tumor volume (GTVD(50%)), and one based on 98% (GTVD(98%)) of the gross tumor volume. The maximum (GTVDmax), minimum (GTVDmin), and mean gross tumor volume dose (GTVDmean) and the dose covering 98% of the gross tumor volume were calculated to evaluate variations in the gross tumor volume dose. RESULTS: Upon switching to GTVD(50%), the variations in GTVDmax and GTVDmean decreased significantly, compared with variations observed for PTVD(95%) (p < 0.01), but the variation in GTVDmin increased significantly (p < 0.01). Upon switching to the GTVD(98%), the variation in GTVDmean decreased significantly compared with that observed for PTVD(95%) (p < 0.01). CONCLUSION: Switching from prescriptions based on 95% of the planning target volume to those based on 98% of the gross tumor volume decreased variations among cases in the overall gross tumor volume dose. Overall, prescriptions based on 98% of the gross tumor volume appear to be more suitable than those based on 95% of the planning target volume in cases of small peripheral lung tumors treated with stereotactic body radiotherapy. |
---|