Cargando…

Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)

PURPOSE: To report normal values of macular and choroidal thickness obtained from a healthy Hispanic population using Optovue (Optovue Inc, Freemont CA, USA) spectral domain optical coherence tomography (SD-OCT). DESIGN: Observational, cross-sectional, correlation study. METHODS: A total of 290 eyes...

Descripción completa

Detalles Bibliográficos
Autores principales: Cortés, Diana A., Roca, Daniela, Navarro, Pedro Iván, Rodríguez, Francisco J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720541/
https://www.ncbi.nlm.nih.gov/pubmed/33372643
http://dx.doi.org/10.1186/s40942-020-00270-9
_version_ 1783619871111643136
author Cortés, Diana A.
Roca, Daniela
Navarro, Pedro Iván
Rodríguez, Francisco J.
author_facet Cortés, Diana A.
Roca, Daniela
Navarro, Pedro Iván
Rodríguez, Francisco J.
author_sort Cortés, Diana A.
collection PubMed
description PURPOSE: To report normal values of macular and choroidal thickness obtained from a healthy Hispanic population using Optovue (Optovue Inc, Freemont CA, USA) spectral domain optical coherence tomography (SD-OCT). DESIGN: Observational, cross-sectional, correlation study. METHODS: A total of 290 eyes (145 healthy subjects) were included; 69% of subjects were female. The median age was 39 ± 29 years (IQR), with a range between 18 and 89 years. The study sample was stratified into three age groups: Group 1, 18–40 years (50.3%), Group 2, 41–60 years (30.7%), and Group 3, older than 61 years (19%). Central macular, perifoveal (inner quadrants), and parafoveal (outer quadrants) thicknesses were estimated. In addition, central and peripheral choroidal thicknesses were estimated. Data analysis was performed to calculate the standardized mean difference according to the variance (Student’s t-test) and its differences with Epidat 4.1. RESULTS: Median macular central thickness was 250 ±30 µm (IQR) with Optovue. Median central choroidal thickness was 263 ± 48 µm (IQR). Median central choroidal thickness was greater than mean peripheral thickness. Macular evaluation showed a statistically significant difference in central, perifoveal, and parafoveal thicknesses, with lower values being recorded for the study sample compared with the manufacturer’s data. CONCLUSIONS: SD-OCT has become a useful tool to obtain high-resolution images of the macula and choroid. This method allows precise assessment of the retinal and choroidal layers to diagnose and follow up posterior segment diseases. We are reporting normal cut-off values of macular and choroidal thicknesses in healthy Hispanic subjects evaluated with Optovue SD-OCT as new diagnostic normal parameters for research and clinical activities.
format Online
Article
Text
id pubmed-7720541
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-77205412020-12-07 Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT) Cortés, Diana A. Roca, Daniela Navarro, Pedro Iván Rodríguez, Francisco J. Int J Retina Vitreous Original Article PURPOSE: To report normal values of macular and choroidal thickness obtained from a healthy Hispanic population using Optovue (Optovue Inc, Freemont CA, USA) spectral domain optical coherence tomography (SD-OCT). DESIGN: Observational, cross-sectional, correlation study. METHODS: A total of 290 eyes (145 healthy subjects) were included; 69% of subjects were female. The median age was 39 ± 29 years (IQR), with a range between 18 and 89 years. The study sample was stratified into three age groups: Group 1, 18–40 years (50.3%), Group 2, 41–60 years (30.7%), and Group 3, older than 61 years (19%). Central macular, perifoveal (inner quadrants), and parafoveal (outer quadrants) thicknesses were estimated. In addition, central and peripheral choroidal thicknesses were estimated. Data analysis was performed to calculate the standardized mean difference according to the variance (Student’s t-test) and its differences with Epidat 4.1. RESULTS: Median macular central thickness was 250 ±30 µm (IQR) with Optovue. Median central choroidal thickness was 263 ± 48 µm (IQR). Median central choroidal thickness was greater than mean peripheral thickness. Macular evaluation showed a statistically significant difference in central, perifoveal, and parafoveal thicknesses, with lower values being recorded for the study sample compared with the manufacturer’s data. CONCLUSIONS: SD-OCT has become a useful tool to obtain high-resolution images of the macula and choroid. This method allows precise assessment of the retinal and choroidal layers to diagnose and follow up posterior segment diseases. We are reporting normal cut-off values of macular and choroidal thicknesses in healthy Hispanic subjects evaluated with Optovue SD-OCT as new diagnostic normal parameters for research and clinical activities. BioMed Central 2020-12-07 /pmc/articles/PMC7720541/ /pubmed/33372643 http://dx.doi.org/10.1186/s40942-020-00270-9 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Original Article
Cortés, Diana A.
Roca, Daniela
Navarro, Pedro Iván
Rodríguez, Francisco J.
Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)
title Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)
title_full Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)
title_fullStr Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)
title_full_unstemmed Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)
title_short Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)
title_sort macular and choroidal thicknesses in a healthy hispanic population evaluated by high-definition spectral-domain optical coherence tomography (sd-oct)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720541/
https://www.ncbi.nlm.nih.gov/pubmed/33372643
http://dx.doi.org/10.1186/s40942-020-00270-9
work_keys_str_mv AT cortesdianaa macularandchoroidalthicknessesinahealthyhispanicpopulationevaluatedbyhighdefinitionspectraldomainopticalcoherencetomographysdoct
AT rocadaniela macularandchoroidalthicknessesinahealthyhispanicpopulationevaluatedbyhighdefinitionspectraldomainopticalcoherencetomographysdoct
AT navarropedroivan macularandchoroidalthicknessesinahealthyhispanicpopulationevaluatedbyhighdefinitionspectraldomainopticalcoherencetomographysdoct
AT rodriguezfranciscoj macularandchoroidalthicknessesinahealthyhispanicpopulationevaluatedbyhighdefinitionspectraldomainopticalcoherencetomographysdoct