Cargando…

Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation

OBJECTIVE: Surgical aortic valve replacement requires a comprehensive transoesophageal echocardiography (TEE) assessment before and after the intervention by cardiac anaesthesiologists. For patients undergoing transfemoral transcatheter aortic valve implantation (TF-TAVI), TEE is not routinely used....

Descripción completa

Detalles Bibliográficos
Autores principales: Musuku, Sridhar Reddy, Cherukupalli, Divya, Di Capua, Christopher, Fitzpatrick, Michael, Sirigaddi, Krishnaveni, Bughrara, Nibras, Singh, Chanderdeep, DeLago, Augustin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Turkish Anaesthesiology and Intensive Care Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720838/
https://www.ncbi.nlm.nih.gov/pubmed/33313589
http://dx.doi.org/10.5152/TJAR.2020.08
_version_ 1783619923244744704
author Musuku, Sridhar Reddy
Cherukupalli, Divya
Di Capua, Christopher
Fitzpatrick, Michael
Sirigaddi, Krishnaveni
Bughrara, Nibras
Singh, Chanderdeep
DeLago, Augustin
author_facet Musuku, Sridhar Reddy
Cherukupalli, Divya
Di Capua, Christopher
Fitzpatrick, Michael
Sirigaddi, Krishnaveni
Bughrara, Nibras
Singh, Chanderdeep
DeLago, Augustin
author_sort Musuku, Sridhar Reddy
collection PubMed
description OBJECTIVE: Surgical aortic valve replacement requires a comprehensive transoesophageal echocardiography (TEE) assessment before and after the intervention by cardiac anaesthesiologists. For patients undergoing transfemoral transcatheter aortic valve implantation (TF-TAVI), TEE is not routinely used. We started using transthoracic echocardiography (TTE) as a diagnostic and monitoring modality during TF-TAVI procedures. The aim of this study is to examine the usefulness of TTE before and after TF-TAVI. We hypothesised that TTE can serve as a screening tool in TF-TAVI patients and help rule out significant paravalvular leaks (PVLs), and serve as a monitoring tool. METHODS: A retrospective, observational study of 24 patients who underwent TF-TAVI with perioperative TTE over a 3-month period was conducted. Intraoperatively, two TTE examinations were performed. The first was a baseline pre-procedural TTE examination after anaesthetic induction, and the second was performed after TAVI valve implantation. Both pre- and post-procedural examinations included five focused TTE views. PVLs were graded as none, non-significant (trace or mild) or significant (moderate or severe). RESULTS: The average age and median body mass index of the patients were 82 years and 28.5 kg m(−2), respectively. The average time recorded for the pre- and post-TAVI TTE examinations were approximately 4 and 5.5 min, respectively. Non-significant PVL was detected in 6 (25%) patients, and no leak was detected in 18 (75%) patients. CONCLUSION: A focused TTE examination was found to be a useful adjunct during TF-TAVI for a cardiac anaesthesiologist in the absence of TEE, and useful in ruling out significant PVLs.
format Online
Article
Text
id pubmed-7720838
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Turkish Anaesthesiology and Intensive Care Society
record_format MEDLINE/PubMed
spelling pubmed-77208382020-12-10 Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation Musuku, Sridhar Reddy Cherukupalli, Divya Di Capua, Christopher Fitzpatrick, Michael Sirigaddi, Krishnaveni Bughrara, Nibras Singh, Chanderdeep DeLago, Augustin Turk J Anaesthesiol Reanim Original Article OBJECTIVE: Surgical aortic valve replacement requires a comprehensive transoesophageal echocardiography (TEE) assessment before and after the intervention by cardiac anaesthesiologists. For patients undergoing transfemoral transcatheter aortic valve implantation (TF-TAVI), TEE is not routinely used. We started using transthoracic echocardiography (TTE) as a diagnostic and monitoring modality during TF-TAVI procedures. The aim of this study is to examine the usefulness of TTE before and after TF-TAVI. We hypothesised that TTE can serve as a screening tool in TF-TAVI patients and help rule out significant paravalvular leaks (PVLs), and serve as a monitoring tool. METHODS: A retrospective, observational study of 24 patients who underwent TF-TAVI with perioperative TTE over a 3-month period was conducted. Intraoperatively, two TTE examinations were performed. The first was a baseline pre-procedural TTE examination after anaesthetic induction, and the second was performed after TAVI valve implantation. Both pre- and post-procedural examinations included five focused TTE views. PVLs were graded as none, non-significant (trace or mild) or significant (moderate or severe). RESULTS: The average age and median body mass index of the patients were 82 years and 28.5 kg m(−2), respectively. The average time recorded for the pre- and post-TAVI TTE examinations were approximately 4 and 5.5 min, respectively. Non-significant PVL was detected in 6 (25%) patients, and no leak was detected in 18 (75%) patients. CONCLUSION: A focused TTE examination was found to be a useful adjunct during TF-TAVI for a cardiac anaesthesiologist in the absence of TEE, and useful in ruling out significant PVLs. Turkish Anaesthesiology and Intensive Care Society 2020-12 2020-05-18 /pmc/articles/PMC7720838/ /pubmed/33313589 http://dx.doi.org/10.5152/TJAR.2020.08 Text en © Copyright 2020 by Turkish Anaesthesiology and Intensive Care Society This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Original Article
Musuku, Sridhar Reddy
Cherukupalli, Divya
Di Capua, Christopher
Fitzpatrick, Michael
Sirigaddi, Krishnaveni
Bughrara, Nibras
Singh, Chanderdeep
DeLago, Augustin
Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation
title Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation
title_full Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation
title_fullStr Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation
title_full_unstemmed Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation
title_short Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation
title_sort point-of-care ultrasound before and after transfemoral transcatheter aortic valve implantation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720838/
https://www.ncbi.nlm.nih.gov/pubmed/33313589
http://dx.doi.org/10.5152/TJAR.2020.08
work_keys_str_mv AT musukusridharreddy pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation
AT cherukupallidivya pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation
AT dicapuachristopher pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation
AT fitzpatrickmichael pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation
AT sirigaddikrishnaveni pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation
AT bughraranibras pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation
AT singhchanderdeep pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation
AT delagoaugustin pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation