Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation
OBJECTIVE: Surgical aortic valve replacement requires a comprehensive transoesophageal echocardiography (TEE) assessment before and after the intervention by cardiac anaesthesiologists. For patients undergoing transfemoral transcatheter aortic valve implantation (TF-TAVI), TEE is not routinely used....
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Turkish Anaesthesiology and Intensive Care Society
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720838/ https://www.ncbi.nlm.nih.gov/pubmed/33313589 http://dx.doi.org/10.5152/TJAR.2020.08 |
_version_ | 1783619923244744704 |
---|---|
author | Musuku, Sridhar Reddy Cherukupalli, Divya Di Capua, Christopher Fitzpatrick, Michael Sirigaddi, Krishnaveni Bughrara, Nibras Singh, Chanderdeep DeLago, Augustin |
author_facet | Musuku, Sridhar Reddy Cherukupalli, Divya Di Capua, Christopher Fitzpatrick, Michael Sirigaddi, Krishnaveni Bughrara, Nibras Singh, Chanderdeep DeLago, Augustin |
author_sort | Musuku, Sridhar Reddy |
collection | PubMed |
description | OBJECTIVE: Surgical aortic valve replacement requires a comprehensive transoesophageal echocardiography (TEE) assessment before and after the intervention by cardiac anaesthesiologists. For patients undergoing transfemoral transcatheter aortic valve implantation (TF-TAVI), TEE is not routinely used. We started using transthoracic echocardiography (TTE) as a diagnostic and monitoring modality during TF-TAVI procedures. The aim of this study is to examine the usefulness of TTE before and after TF-TAVI. We hypothesised that TTE can serve as a screening tool in TF-TAVI patients and help rule out significant paravalvular leaks (PVLs), and serve as a monitoring tool. METHODS: A retrospective, observational study of 24 patients who underwent TF-TAVI with perioperative TTE over a 3-month period was conducted. Intraoperatively, two TTE examinations were performed. The first was a baseline pre-procedural TTE examination after anaesthetic induction, and the second was performed after TAVI valve implantation. Both pre- and post-procedural examinations included five focused TTE views. PVLs were graded as none, non-significant (trace or mild) or significant (moderate or severe). RESULTS: The average age and median body mass index of the patients were 82 years and 28.5 kg m(−2), respectively. The average time recorded for the pre- and post-TAVI TTE examinations were approximately 4 and 5.5 min, respectively. Non-significant PVL was detected in 6 (25%) patients, and no leak was detected in 18 (75%) patients. CONCLUSION: A focused TTE examination was found to be a useful adjunct during TF-TAVI for a cardiac anaesthesiologist in the absence of TEE, and useful in ruling out significant PVLs. |
format | Online Article Text |
id | pubmed-7720838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Turkish Anaesthesiology and Intensive Care Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-77208382020-12-10 Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation Musuku, Sridhar Reddy Cherukupalli, Divya Di Capua, Christopher Fitzpatrick, Michael Sirigaddi, Krishnaveni Bughrara, Nibras Singh, Chanderdeep DeLago, Augustin Turk J Anaesthesiol Reanim Original Article OBJECTIVE: Surgical aortic valve replacement requires a comprehensive transoesophageal echocardiography (TEE) assessment before and after the intervention by cardiac anaesthesiologists. For patients undergoing transfemoral transcatheter aortic valve implantation (TF-TAVI), TEE is not routinely used. We started using transthoracic echocardiography (TTE) as a diagnostic and monitoring modality during TF-TAVI procedures. The aim of this study is to examine the usefulness of TTE before and after TF-TAVI. We hypothesised that TTE can serve as a screening tool in TF-TAVI patients and help rule out significant paravalvular leaks (PVLs), and serve as a monitoring tool. METHODS: A retrospective, observational study of 24 patients who underwent TF-TAVI with perioperative TTE over a 3-month period was conducted. Intraoperatively, two TTE examinations were performed. The first was a baseline pre-procedural TTE examination after anaesthetic induction, and the second was performed after TAVI valve implantation. Both pre- and post-procedural examinations included five focused TTE views. PVLs were graded as none, non-significant (trace or mild) or significant (moderate or severe). RESULTS: The average age and median body mass index of the patients were 82 years and 28.5 kg m(−2), respectively. The average time recorded for the pre- and post-TAVI TTE examinations were approximately 4 and 5.5 min, respectively. Non-significant PVL was detected in 6 (25%) patients, and no leak was detected in 18 (75%) patients. CONCLUSION: A focused TTE examination was found to be a useful adjunct during TF-TAVI for a cardiac anaesthesiologist in the absence of TEE, and useful in ruling out significant PVLs. Turkish Anaesthesiology and Intensive Care Society 2020-12 2020-05-18 /pmc/articles/PMC7720838/ /pubmed/33313589 http://dx.doi.org/10.5152/TJAR.2020.08 Text en © Copyright 2020 by Turkish Anaesthesiology and Intensive Care Society This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Original Article Musuku, Sridhar Reddy Cherukupalli, Divya Di Capua, Christopher Fitzpatrick, Michael Sirigaddi, Krishnaveni Bughrara, Nibras Singh, Chanderdeep DeLago, Augustin Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation |
title | Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation |
title_full | Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation |
title_fullStr | Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation |
title_full_unstemmed | Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation |
title_short | Point-of-Care Ultrasound Before and After Transfemoral Transcatheter Aortic Valve Implantation |
title_sort | point-of-care ultrasound before and after transfemoral transcatheter aortic valve implantation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720838/ https://www.ncbi.nlm.nih.gov/pubmed/33313589 http://dx.doi.org/10.5152/TJAR.2020.08 |
work_keys_str_mv | AT musukusridharreddy pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation AT cherukupallidivya pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation AT dicapuachristopher pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation AT fitzpatrickmichael pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation AT sirigaddikrishnaveni pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation AT bughraranibras pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation AT singhchanderdeep pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation AT delagoaugustin pointofcareultrasoundbeforeandaftertransfemoraltranscatheteraorticvalveimplantation |