Cargando…
Impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, DNA and nanoparticles in µL-volumes
Specific intracellular manipulation of animal cells is a persistent goal in experimental cell biology. Such manipulations allow precise and targeted interference with signaling cascades, metabolic pathways, or bi-molecular interactions for subsequent tracking of functional consequences. However, mos...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7721805/ https://www.ncbi.nlm.nih.gov/pubmed/33288771 http://dx.doi.org/10.1038/s41598-020-78096-6 |
_version_ | 1783620094594646016 |
---|---|
author | Stolwijk, Judith A. Wegener, Joachim |
author_facet | Stolwijk, Judith A. Wegener, Joachim |
author_sort | Stolwijk, Judith A. |
collection | PubMed |
description | Specific intracellular manipulation of animal cells is a persistent goal in experimental cell biology. Such manipulations allow precise and targeted interference with signaling cascades, metabolic pathways, or bi-molecular interactions for subsequent tracking of functional consequences. However, most biomolecules capable of molecular recognition are membrane impermeable. The ability to introduce these molecules into the cytoplasm and then to apply appropriate readouts to monitor the corresponding cell response could prove to be an important research tool. This study describes such an experimental approach combining in situ electroporation (ISE) as a means to efficiently deliver biomolecules to the cytoplasm with an impedance-based, time-resolved analysis of cell status using electric cell-substrate impedance sensing (ECIS). In this approach, gold-film electrodes, deposited on the bottom of regular culture dishes, are used for both electroporation and monitoring. The design of the electrode layout and measurement chamber allows working with sample volumes as small as 10 µL. A miniaturized setup for combined electroporation and impedance sensing (µISE-ECIS) was applied to load different adherent cells with bioactive macromolecules including enzymes, antibodies, nucleic acids and quantum dot nanoparticles. The cell response after loading the cytoplasm with RNase A or cytochrome c (in the presence or absence of caspase inhibitors) was tracked by non-invasive impedance readings in real-time. |
format | Online Article Text |
id | pubmed-7721805 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-77218052020-12-09 Impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, DNA and nanoparticles in µL-volumes Stolwijk, Judith A. Wegener, Joachim Sci Rep Article Specific intracellular manipulation of animal cells is a persistent goal in experimental cell biology. Such manipulations allow precise and targeted interference with signaling cascades, metabolic pathways, or bi-molecular interactions for subsequent tracking of functional consequences. However, most biomolecules capable of molecular recognition are membrane impermeable. The ability to introduce these molecules into the cytoplasm and then to apply appropriate readouts to monitor the corresponding cell response could prove to be an important research tool. This study describes such an experimental approach combining in situ electroporation (ISE) as a means to efficiently deliver biomolecules to the cytoplasm with an impedance-based, time-resolved analysis of cell status using electric cell-substrate impedance sensing (ECIS). In this approach, gold-film electrodes, deposited on the bottom of regular culture dishes, are used for both electroporation and monitoring. The design of the electrode layout and measurement chamber allows working with sample volumes as small as 10 µL. A miniaturized setup for combined electroporation and impedance sensing (µISE-ECIS) was applied to load different adherent cells with bioactive macromolecules including enzymes, antibodies, nucleic acids and quantum dot nanoparticles. The cell response after loading the cytoplasm with RNase A or cytochrome c (in the presence or absence of caspase inhibitors) was tracked by non-invasive impedance readings in real-time. Nature Publishing Group UK 2020-12-07 /pmc/articles/PMC7721805/ /pubmed/33288771 http://dx.doi.org/10.1038/s41598-020-78096-6 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Stolwijk, Judith A. Wegener, Joachim Impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, DNA and nanoparticles in µL-volumes |
title | Impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, DNA and nanoparticles in µL-volumes |
title_full | Impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, DNA and nanoparticles in µL-volumes |
title_fullStr | Impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, DNA and nanoparticles in µL-volumes |
title_full_unstemmed | Impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, DNA and nanoparticles in µL-volumes |
title_short | Impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, DNA and nanoparticles in µL-volumes |
title_sort | impedance analysis of adherent cells after in situ electroporation-mediated delivery of bioactive proteins, dna and nanoparticles in µl-volumes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7721805/ https://www.ncbi.nlm.nih.gov/pubmed/33288771 http://dx.doi.org/10.1038/s41598-020-78096-6 |
work_keys_str_mv | AT stolwijkjuditha impedanceanalysisofadherentcellsafterinsituelectroporationmediateddeliveryofbioactiveproteinsdnaandnanoparticlesinμlvolumes AT wegenerjoachim impedanceanalysisofadherentcellsafterinsituelectroporationmediateddeliveryofbioactiveproteinsdnaandnanoparticlesinμlvolumes |