Cargando…

An overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures

Thromboelastography (TEG), a hemostatic point-of-care assay, provides global information about fibrin formation, platelet activation, and clot retraction in real-time. As it is an operator-dependent technique, error in any phase of the testing process can result in the misinterpretation of the throm...

Descripción completa

Detalles Bibliográficos
Autores principales: Mukhopadhyay, Tapasyapreeti, Subramanian, Arulselvi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7723805/
https://www.ncbi.nlm.nih.gov/pubmed/33319008
http://dx.doi.org/10.1016/j.plabm.2020.e00193
_version_ 1783620419661594624
author Mukhopadhyay, Tapasyapreeti
Subramanian, Arulselvi
author_facet Mukhopadhyay, Tapasyapreeti
Subramanian, Arulselvi
author_sort Mukhopadhyay, Tapasyapreeti
collection PubMed
description Thromboelastography (TEG), a hemostatic point-of-care assay, provides global information about fibrin formation, platelet activation, and clot retraction in real-time. As it is an operator-dependent technique, error in any phase of the testing process can result in the misinterpretation of the thromboelastogram, and subsequently lead to mismanagement of the patient, wastage of blood products besides increasing the financial burden on the hospital and the patient. The present paper describes the possible errors leading to wrong thromboelastogram interpretation, and the respective preventive measure. In the light of limited resources available for operational challenges in TEG, this review paper can prove to be helpful.
format Online
Article
Text
id pubmed-7723805
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-77238052020-12-13 An overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures Mukhopadhyay, Tapasyapreeti Subramanian, Arulselvi Pract Lab Med Article Thromboelastography (TEG), a hemostatic point-of-care assay, provides global information about fibrin formation, platelet activation, and clot retraction in real-time. As it is an operator-dependent technique, error in any phase of the testing process can result in the misinterpretation of the thromboelastogram, and subsequently lead to mismanagement of the patient, wastage of blood products besides increasing the financial burden on the hospital and the patient. The present paper describes the possible errors leading to wrong thromboelastogram interpretation, and the respective preventive measure. In the light of limited resources available for operational challenges in TEG, this review paper can prove to be helpful. Elsevier 2020-11-28 /pmc/articles/PMC7723805/ /pubmed/33319008 http://dx.doi.org/10.1016/j.plabm.2020.e00193 Text en © 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mukhopadhyay, Tapasyapreeti
Subramanian, Arulselvi
An overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures
title An overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures
title_full An overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures
title_fullStr An overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures
title_full_unstemmed An overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures
title_short An overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures
title_sort overview of the potential sources of diagnostic errors in (classic) thromboelastography curve interpretation and preventive measures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7723805/
https://www.ncbi.nlm.nih.gov/pubmed/33319008
http://dx.doi.org/10.1016/j.plabm.2020.e00193
work_keys_str_mv AT mukhopadhyaytapasyapreeti anoverviewofthepotentialsourcesofdiagnosticerrorsinclassicthromboelastographycurveinterpretationandpreventivemeasures
AT subramanianarulselvi anoverviewofthepotentialsourcesofdiagnosticerrorsinclassicthromboelastographycurveinterpretationandpreventivemeasures
AT mukhopadhyaytapasyapreeti overviewofthepotentialsourcesofdiagnosticerrorsinclassicthromboelastographycurveinterpretationandpreventivemeasures
AT subramanianarulselvi overviewofthepotentialsourcesofdiagnosticerrorsinclassicthromboelastographycurveinterpretationandpreventivemeasures