Cargando…

Critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach

Immunohistochemical staining of tissue sections is a vital technique in pathological diagnostics and theranostics. Several kinds of detection systems are available—each of them with their advantages and disadvantages. Here we present the results of a study assessing a prototype immunohistochemical d...

Descripción completa

Detalles Bibliográficos
Autores principales: Seidl, M., Weinhold, B., Jacobsen, L., Rasmussen, O. F., Werner, M., Aumann, Konrad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7723932/
https://www.ncbi.nlm.nih.gov/pubmed/32767119
http://dx.doi.org/10.1007/s00418-020-01906-5
_version_ 1783620448713441280
author Seidl, M.
Weinhold, B.
Jacobsen, L.
Rasmussen, O. F.
Werner, M.
Aumann, Konrad
author_facet Seidl, M.
Weinhold, B.
Jacobsen, L.
Rasmussen, O. F.
Werner, M.
Aumann, Konrad
author_sort Seidl, M.
collection PubMed
description Immunohistochemical staining of tissue sections is a vital technique in pathological diagnostics and theranostics. Several kinds of detection systems are available—each of them with their advantages and disadvantages. Here we present the results of a study assessing a prototype immunohistochemical detection technology (PIDT) for visualization of antigens in tissue sections. Different tumor tissues (n = 11) were stained with selected antibodies (n = 30) and a subset of these under different fixation conditions. The staining properties were assessed according to six staining quality parameters (signal distribution, intensity, tissue and slide background, acutance, clarity of details, and subcellular morphological details), and the results were compared with those of a well-established detection system (EnVision FLEX). Overall, both detection methods revealed good to optimal results regarding the evaluated parameters even under unfavorable fixation conditions. However, with the prototype detection technology a quicker turnaround time was reached primarily due to shorter primary antibody incubation times. Moreover, PIDT-stained tissues showed higher signal intensity and a uniform signal distribution over the tissue slide, still, with well-preserved tissue morphology and without impairing the gradation of staining intensity of different cell types. In particular, the prototype detection technology performed better in poorly or delayed fixed tissue. In situations where rapid and profound results are in demand, and particularly in the context of a small laboratory setting, this prototype detection technology could be a useful addition to the established detection systems. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00418-020-01906-5) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7723932
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-77239322020-12-14 Critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach Seidl, M. Weinhold, B. Jacobsen, L. Rasmussen, O. F. Werner, M. Aumann, Konrad Histochem Cell Biol Short Communication Immunohistochemical staining of tissue sections is a vital technique in pathological diagnostics and theranostics. Several kinds of detection systems are available—each of them with their advantages and disadvantages. Here we present the results of a study assessing a prototype immunohistochemical detection technology (PIDT) for visualization of antigens in tissue sections. Different tumor tissues (n = 11) were stained with selected antibodies (n = 30) and a subset of these under different fixation conditions. The staining properties were assessed according to six staining quality parameters (signal distribution, intensity, tissue and slide background, acutance, clarity of details, and subcellular morphological details), and the results were compared with those of a well-established detection system (EnVision FLEX). Overall, both detection methods revealed good to optimal results regarding the evaluated parameters even under unfavorable fixation conditions. However, with the prototype detection technology a quicker turnaround time was reached primarily due to shorter primary antibody incubation times. Moreover, PIDT-stained tissues showed higher signal intensity and a uniform signal distribution over the tissue slide, still, with well-preserved tissue morphology and without impairing the gradation of staining intensity of different cell types. In particular, the prototype detection technology performed better in poorly or delayed fixed tissue. In situations where rapid and profound results are in demand, and particularly in the context of a small laboratory setting, this prototype detection technology could be a useful addition to the established detection systems. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00418-020-01906-5) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2020-08-07 2020 /pmc/articles/PMC7723932/ /pubmed/32767119 http://dx.doi.org/10.1007/s00418-020-01906-5 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Short Communication
Seidl, M.
Weinhold, B.
Jacobsen, L.
Rasmussen, O. F.
Werner, M.
Aumann, Konrad
Critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach
title Critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach
title_full Critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach
title_fullStr Critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach
title_full_unstemmed Critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach
title_short Critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach
title_sort critical assessment of staining properties of a new visualization technology: a novel, rapid and powerful immunohistochemical detection approach
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7723932/
https://www.ncbi.nlm.nih.gov/pubmed/32767119
http://dx.doi.org/10.1007/s00418-020-01906-5
work_keys_str_mv AT seidlm criticalassessmentofstainingpropertiesofanewvisualizationtechnologyanovelrapidandpowerfulimmunohistochemicaldetectionapproach
AT weinholdb criticalassessmentofstainingpropertiesofanewvisualizationtechnologyanovelrapidandpowerfulimmunohistochemicaldetectionapproach
AT jacobsenl criticalassessmentofstainingpropertiesofanewvisualizationtechnologyanovelrapidandpowerfulimmunohistochemicaldetectionapproach
AT rasmussenof criticalassessmentofstainingpropertiesofanewvisualizationtechnologyanovelrapidandpowerfulimmunohistochemicaldetectionapproach
AT wernerm criticalassessmentofstainingpropertiesofanewvisualizationtechnologyanovelrapidandpowerfulimmunohistochemicaldetectionapproach
AT aumannkonrad criticalassessmentofstainingpropertiesofanewvisualizationtechnologyanovelrapidandpowerfulimmunohistochemicaldetectionapproach