Cargando…

Point‐of‐care ultrasound: Closing guideline gaps in screening for valvular heart disease

BACKGROUND: A linear increase in the number of valvular heart disease is expected due to the aging population, yet most patients with severe valvular heart disease remain undiagnosed. HYPOTHESIS: POCUS can serve as a screening tool for valvular heart disease. METHODS: We reviewed the literature to a...

Descripción completa

Detalles Bibliográficos
Autores principales: Hammadah, Muhammad, Ponce, Christopher, Sorajja, Paul, Cavalcante, João L., Garcia, Santiago, Gössl, Mario
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wiley Periodicals, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724242/
https://www.ncbi.nlm.nih.gov/pubmed/33174635
http://dx.doi.org/10.1002/clc.23499
_version_ 1783620504673845248
author Hammadah, Muhammad
Ponce, Christopher
Sorajja, Paul
Cavalcante, João L.
Garcia, Santiago
Gössl, Mario
author_facet Hammadah, Muhammad
Ponce, Christopher
Sorajja, Paul
Cavalcante, João L.
Garcia, Santiago
Gössl, Mario
author_sort Hammadah, Muhammad
collection PubMed
description BACKGROUND: A linear increase in the number of valvular heart disease is expected due to the aging population, yet most patients with severe valvular heart disease remain undiagnosed. HYPOTHESIS: POCUS can serve as a screening tool for valvular heart disease. METHODS: We reviewed the literature to assess the strengths and limitations of POCUS in screening and diagnosing valvular heart disease. RESULTS: POCUS is an accurate, affordable, accessible, and comprehensive tool. It has a fast learning curve and can prevent unnecessary and more expensive imaging. Challenges include training availability, lack of simplified screening protocols, and reimbursement. Large scale valvular screening data utilizing POCUS is not available. CONCLUSION: POCUS can serve as a screening tool and guide the management of patients with valvular heart disease. More data is needed about its efficacy and cost‐effectiveness in the screening of patients with valvular heart disease.
format Online
Article
Text
id pubmed-7724242
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wiley Periodicals, Inc.
record_format MEDLINE/PubMed
spelling pubmed-77242422020-12-11 Point‐of‐care ultrasound: Closing guideline gaps in screening for valvular heart disease Hammadah, Muhammad Ponce, Christopher Sorajja, Paul Cavalcante, João L. Garcia, Santiago Gössl, Mario Clin Cardiol Reviews BACKGROUND: A linear increase in the number of valvular heart disease is expected due to the aging population, yet most patients with severe valvular heart disease remain undiagnosed. HYPOTHESIS: POCUS can serve as a screening tool for valvular heart disease. METHODS: We reviewed the literature to assess the strengths and limitations of POCUS in screening and diagnosing valvular heart disease. RESULTS: POCUS is an accurate, affordable, accessible, and comprehensive tool. It has a fast learning curve and can prevent unnecessary and more expensive imaging. Challenges include training availability, lack of simplified screening protocols, and reimbursement. Large scale valvular screening data utilizing POCUS is not available. CONCLUSION: POCUS can serve as a screening tool and guide the management of patients with valvular heart disease. More data is needed about its efficacy and cost‐effectiveness in the screening of patients with valvular heart disease. Wiley Periodicals, Inc. 2020-11-11 /pmc/articles/PMC7724242/ /pubmed/33174635 http://dx.doi.org/10.1002/clc.23499 Text en © 2020 The Authors. Clinical Cardiology published by Wiley Periodicals LLC. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Reviews
Hammadah, Muhammad
Ponce, Christopher
Sorajja, Paul
Cavalcante, João L.
Garcia, Santiago
Gössl, Mario
Point‐of‐care ultrasound: Closing guideline gaps in screening for valvular heart disease
title Point‐of‐care ultrasound: Closing guideline gaps in screening for valvular heart disease
title_full Point‐of‐care ultrasound: Closing guideline gaps in screening for valvular heart disease
title_fullStr Point‐of‐care ultrasound: Closing guideline gaps in screening for valvular heart disease
title_full_unstemmed Point‐of‐care ultrasound: Closing guideline gaps in screening for valvular heart disease
title_short Point‐of‐care ultrasound: Closing guideline gaps in screening for valvular heart disease
title_sort point‐of‐care ultrasound: closing guideline gaps in screening for valvular heart disease
topic Reviews
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724242/
https://www.ncbi.nlm.nih.gov/pubmed/33174635
http://dx.doi.org/10.1002/clc.23499
work_keys_str_mv AT hammadahmuhammad pointofcareultrasoundclosingguidelinegapsinscreeningforvalvularheartdisease
AT poncechristopher pointofcareultrasoundclosingguidelinegapsinscreeningforvalvularheartdisease
AT sorajjapaul pointofcareultrasoundclosingguidelinegapsinscreeningforvalvularheartdisease
AT cavalcantejoaol pointofcareultrasoundclosingguidelinegapsinscreeningforvalvularheartdisease
AT garciasantiago pointofcareultrasoundclosingguidelinegapsinscreeningforvalvularheartdisease
AT gosslmario pointofcareultrasoundclosingguidelinegapsinscreeningforvalvularheartdisease