Cargando…

Correlates of Indoor Concentration of Carbon Monoxide in Residential Buildings in Gondar Town, Northwest Ethiopia

This community-based cross-sectional study was conducted to investigate the indoor concentration of carbon monoxide (CO) and associated factors in residential buildings of Gondar town, northwest Ethiopia. Data were collected from 384 occupied buildings and occupants using CO meter, interviewers admi...

Descripción completa

Detalles Bibliográficos
Autores principales: Gizaw, Zemichael, Teka, Zinabu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724403/
https://www.ncbi.nlm.nih.gov/pubmed/33335399
http://dx.doi.org/10.1177/1178630220978234
_version_ 1783620528073867264
author Gizaw, Zemichael
Teka, Zinabu
author_facet Gizaw, Zemichael
Teka, Zinabu
author_sort Gizaw, Zemichael
collection PubMed
description This community-based cross-sectional study was conducted to investigate the indoor concentration of carbon monoxide (CO) and associated factors in residential buildings of Gondar town, northwest Ethiopia. Data were collected from 384 occupied buildings and occupants using CO meter, interviewers administered questionnaire, and observation checklists. Multivariable binary logistic regression analysis was used for controlling the possible effect of confounders and to identify factors associated with indoor concentration of CO on the basis of adjusted odds ratio (AOR) with 95% confidence interval (CI) and P < .05. The current study revealed that 224(58.3%) occupied buildings had the concentration of CO above the permissible value for 15 minute exposure for living rooms (100 mg/m(3)). Indoor concentration of CO was significantly associated with access to health information [AOR = 0.081, 95%CI = (0.008, 0.803)], number of rooms [AOR = 0.016, 95% CI = (0.001, 0.279)], area of occupied room [AOR = 0.019, 95% CI = (0.001, 0.237)], buildings located away from main roads/garages [AOR = 0.045, 95% CI = (0.005, 0.415)], clean energy sources [AOR = 0.010, 95% CI = (0.001, 0.123)], presence of separate kitchen [AOR = 0.030, 95% CI = (0.004, 0.221)], no incensing in the room [AOR = 0.055, 95% CI = (0.006,0.499)] and measurements in the afternoon [AOR = 0.114, 95% CI = (0.013, 0.965)]. Residents, therefore, need to use clean energy sources, construct a kitchen with a properly constructed chimneys away from the main building, and avoid incensing inside the indoor environment.
format Online
Article
Text
id pubmed-7724403
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-77244032020-12-16 Correlates of Indoor Concentration of Carbon Monoxide in Residential Buildings in Gondar Town, Northwest Ethiopia Gizaw, Zemichael Teka, Zinabu Environ Health Insights Original Research This community-based cross-sectional study was conducted to investigate the indoor concentration of carbon monoxide (CO) and associated factors in residential buildings of Gondar town, northwest Ethiopia. Data were collected from 384 occupied buildings and occupants using CO meter, interviewers administered questionnaire, and observation checklists. Multivariable binary logistic regression analysis was used for controlling the possible effect of confounders and to identify factors associated with indoor concentration of CO on the basis of adjusted odds ratio (AOR) with 95% confidence interval (CI) and P < .05. The current study revealed that 224(58.3%) occupied buildings had the concentration of CO above the permissible value for 15 minute exposure for living rooms (100 mg/m(3)). Indoor concentration of CO was significantly associated with access to health information [AOR = 0.081, 95%CI = (0.008, 0.803)], number of rooms [AOR = 0.016, 95% CI = (0.001, 0.279)], area of occupied room [AOR = 0.019, 95% CI = (0.001, 0.237)], buildings located away from main roads/garages [AOR = 0.045, 95% CI = (0.005, 0.415)], clean energy sources [AOR = 0.010, 95% CI = (0.001, 0.123)], presence of separate kitchen [AOR = 0.030, 95% CI = (0.004, 0.221)], no incensing in the room [AOR = 0.055, 95% CI = (0.006,0.499)] and measurements in the afternoon [AOR = 0.114, 95% CI = (0.013, 0.965)]. Residents, therefore, need to use clean energy sources, construct a kitchen with a properly constructed chimneys away from the main building, and avoid incensing inside the indoor environment. SAGE Publications 2020-12-06 /pmc/articles/PMC7724403/ /pubmed/33335399 http://dx.doi.org/10.1177/1178630220978234 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Gizaw, Zemichael
Teka, Zinabu
Correlates of Indoor Concentration of Carbon Monoxide in Residential Buildings in Gondar Town, Northwest Ethiopia
title Correlates of Indoor Concentration of Carbon Monoxide in Residential Buildings in Gondar Town, Northwest Ethiopia
title_full Correlates of Indoor Concentration of Carbon Monoxide in Residential Buildings in Gondar Town, Northwest Ethiopia
title_fullStr Correlates of Indoor Concentration of Carbon Monoxide in Residential Buildings in Gondar Town, Northwest Ethiopia
title_full_unstemmed Correlates of Indoor Concentration of Carbon Monoxide in Residential Buildings in Gondar Town, Northwest Ethiopia
title_short Correlates of Indoor Concentration of Carbon Monoxide in Residential Buildings in Gondar Town, Northwest Ethiopia
title_sort correlates of indoor concentration of carbon monoxide in residential buildings in gondar town, northwest ethiopia
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724403/
https://www.ncbi.nlm.nih.gov/pubmed/33335399
http://dx.doi.org/10.1177/1178630220978234
work_keys_str_mv AT gizawzemichael correlatesofindoorconcentrationofcarbonmonoxideinresidentialbuildingsingondartownnorthwestethiopia
AT tekazinabu correlatesofindoorconcentrationofcarbonmonoxideinresidentialbuildingsingondartownnorthwestethiopia