Cargando…

INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS

OBJECTIVE: To measure the intra- and inter-rater reliability of a biophotogrammetric assessment protocol for thoracoabdominal motion in preterm infants. METHODS: This is an analytical cross-sectional study. Footage of 40 preterm infants was made in two views (lateral and anterior). The babies were p...

Descripción completa

Detalles Bibliográficos
Autores principales: Campos, Juliana Vieira, Moreno, Mariana Alves, Silva, Ricardo de Bastos, da Silva, Jessica Neves Quirino, de Carvalho, Milena Ferreira, dos Santos, Rayssa Christina Abreu, Peres, Rodrigo Tosta, Santos, Rosana da Silva, Ferreira, Halina Cidrini
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade de Pediatria de São Paulo 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724690/
https://www.ncbi.nlm.nih.gov/pubmed/33295596
http://dx.doi.org/10.1590/1984-0462/2021/39/2020034
_version_ 1783620573487693824
author Campos, Juliana Vieira
Moreno, Mariana Alves
Silva, Ricardo de Bastos
da Silva, Jessica Neves Quirino
de Carvalho, Milena Ferreira
dos Santos, Rayssa Christina Abreu
Peres, Rodrigo Tosta
Santos, Rosana da Silva
Ferreira, Halina Cidrini
author_facet Campos, Juliana Vieira
Moreno, Mariana Alves
Silva, Ricardo de Bastos
da Silva, Jessica Neves Quirino
de Carvalho, Milena Ferreira
dos Santos, Rayssa Christina Abreu
Peres, Rodrigo Tosta
Santos, Rosana da Silva
Ferreira, Halina Cidrini
author_sort Campos, Juliana Vieira
collection PubMed
description OBJECTIVE: To measure the intra- and inter-rater reliability of a biophotogrammetric assessment protocol for thoracoabdominal motion in preterm infants. METHODS: This is an analytical cross-sectional study. Footage of 40 preterm infants was made in two views (lateral and anterior). The babies were placed in the supine position, with retroverted pelvis and semiflexed knees. Acrylic markers were positioned on surgical tape in eight predetermined anatomical points. We analyzed 4 variables in lateral view and 11 in anterior view (angular and linear) (ImageJ(®)), divided into two stages: 1. same frames - three blinded evaluators analyzed frames previously selected by the main researcher (inter-rater analysis 1), reviewing these same frames after 15 days (intra-rater analysis 1); 2. different frames - each evaluator selected the frames from the original video and repeated the protocol (inter-rater analysis 2), with a review after 15 days (intra-rater analysis 2). In stage 2, we tested the reliability of the entire process, from image selection to the analysis of variables. Data agreement and reproducibility were obtained by the intraclass correlation coefficient (ICC). RESULTS: Agreement was high, particularly in angular variables (ICC 0.82 to 0.99). Linear variables ranged between very good and excellent in analysis 1 (same frames: ICC 0.64 to 0.99) and analysis 2 (different frames: ICC 0.44 to 0.89). CONCLUSIONS: The present study suggests that the proposed protocol for the thoracoabdominal motion analysis of preterm neonates has high reliability.
format Online
Article
Text
id pubmed-7724690
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Sociedade de Pediatria de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-77246902020-12-15 INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS Campos, Juliana Vieira Moreno, Mariana Alves Silva, Ricardo de Bastos da Silva, Jessica Neves Quirino de Carvalho, Milena Ferreira dos Santos, Rayssa Christina Abreu Peres, Rodrigo Tosta Santos, Rosana da Silva Ferreira, Halina Cidrini Rev Paul Pediatr Original Article OBJECTIVE: To measure the intra- and inter-rater reliability of a biophotogrammetric assessment protocol for thoracoabdominal motion in preterm infants. METHODS: This is an analytical cross-sectional study. Footage of 40 preterm infants was made in two views (lateral and anterior). The babies were placed in the supine position, with retroverted pelvis and semiflexed knees. Acrylic markers were positioned on surgical tape in eight predetermined anatomical points. We analyzed 4 variables in lateral view and 11 in anterior view (angular and linear) (ImageJ(®)), divided into two stages: 1. same frames - three blinded evaluators analyzed frames previously selected by the main researcher (inter-rater analysis 1), reviewing these same frames after 15 days (intra-rater analysis 1); 2. different frames - each evaluator selected the frames from the original video and repeated the protocol (inter-rater analysis 2), with a review after 15 days (intra-rater analysis 2). In stage 2, we tested the reliability of the entire process, from image selection to the analysis of variables. Data agreement and reproducibility were obtained by the intraclass correlation coefficient (ICC). RESULTS: Agreement was high, particularly in angular variables (ICC 0.82 to 0.99). Linear variables ranged between very good and excellent in analysis 1 (same frames: ICC 0.64 to 0.99) and analysis 2 (different frames: ICC 0.44 to 0.89). CONCLUSIONS: The present study suggests that the proposed protocol for the thoracoabdominal motion analysis of preterm neonates has high reliability. Sociedade de Pediatria de São Paulo 2020-12-07 /pmc/articles/PMC7724690/ /pubmed/33295596 http://dx.doi.org/10.1590/1984-0462/2021/39/2020034 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Original Article
Campos, Juliana Vieira
Moreno, Mariana Alves
Silva, Ricardo de Bastos
da Silva, Jessica Neves Quirino
de Carvalho, Milena Ferreira
dos Santos, Rayssa Christina Abreu
Peres, Rodrigo Tosta
Santos, Rosana da Silva
Ferreira, Halina Cidrini
INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS
title INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS
title_full INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS
title_fullStr INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS
title_full_unstemmed INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS
title_short INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS
title_sort intra- and inter-rater reliability of a biophotogrammetric assessment protocol for preterm infants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724690/
https://www.ncbi.nlm.nih.gov/pubmed/33295596
http://dx.doi.org/10.1590/1984-0462/2021/39/2020034
work_keys_str_mv AT camposjulianavieira intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants
AT morenomarianaalves intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants
AT silvaricardodebastos intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants
AT dasilvajessicanevesquirino intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants
AT decarvalhomilenaferreira intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants
AT dossantosrayssachristinaabreu intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants
AT peresrodrigotosta intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants
AT santosrosanadasilva intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants
AT ferreirahalinacidrini intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants