Cargando…
INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS
OBJECTIVE: To measure the intra- and inter-rater reliability of a biophotogrammetric assessment protocol for thoracoabdominal motion in preterm infants. METHODS: This is an analytical cross-sectional study. Footage of 40 preterm infants was made in two views (lateral and anterior). The babies were p...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade de Pediatria de São Paulo
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724690/ https://www.ncbi.nlm.nih.gov/pubmed/33295596 http://dx.doi.org/10.1590/1984-0462/2021/39/2020034 |
_version_ | 1783620573487693824 |
---|---|
author | Campos, Juliana Vieira Moreno, Mariana Alves Silva, Ricardo de Bastos da Silva, Jessica Neves Quirino de Carvalho, Milena Ferreira dos Santos, Rayssa Christina Abreu Peres, Rodrigo Tosta Santos, Rosana da Silva Ferreira, Halina Cidrini |
author_facet | Campos, Juliana Vieira Moreno, Mariana Alves Silva, Ricardo de Bastos da Silva, Jessica Neves Quirino de Carvalho, Milena Ferreira dos Santos, Rayssa Christina Abreu Peres, Rodrigo Tosta Santos, Rosana da Silva Ferreira, Halina Cidrini |
author_sort | Campos, Juliana Vieira |
collection | PubMed |
description | OBJECTIVE: To measure the intra- and inter-rater reliability of a biophotogrammetric assessment protocol for thoracoabdominal motion in preterm infants. METHODS: This is an analytical cross-sectional study. Footage of 40 preterm infants was made in two views (lateral and anterior). The babies were placed in the supine position, with retroverted pelvis and semiflexed knees. Acrylic markers were positioned on surgical tape in eight predetermined anatomical points. We analyzed 4 variables in lateral view and 11 in anterior view (angular and linear) (ImageJ(®)), divided into two stages: 1. same frames - three blinded evaluators analyzed frames previously selected by the main researcher (inter-rater analysis 1), reviewing these same frames after 15 days (intra-rater analysis 1); 2. different frames - each evaluator selected the frames from the original video and repeated the protocol (inter-rater analysis 2), with a review after 15 days (intra-rater analysis 2). In stage 2, we tested the reliability of the entire process, from image selection to the analysis of variables. Data agreement and reproducibility were obtained by the intraclass correlation coefficient (ICC). RESULTS: Agreement was high, particularly in angular variables (ICC 0.82 to 0.99). Linear variables ranged between very good and excellent in analysis 1 (same frames: ICC 0.64 to 0.99) and analysis 2 (different frames: ICC 0.44 to 0.89). CONCLUSIONS: The present study suggests that the proposed protocol for the thoracoabdominal motion analysis of preterm neonates has high reliability. |
format | Online Article Text |
id | pubmed-7724690 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Sociedade de Pediatria de São Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-77246902020-12-15 INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS Campos, Juliana Vieira Moreno, Mariana Alves Silva, Ricardo de Bastos da Silva, Jessica Neves Quirino de Carvalho, Milena Ferreira dos Santos, Rayssa Christina Abreu Peres, Rodrigo Tosta Santos, Rosana da Silva Ferreira, Halina Cidrini Rev Paul Pediatr Original Article OBJECTIVE: To measure the intra- and inter-rater reliability of a biophotogrammetric assessment protocol for thoracoabdominal motion in preterm infants. METHODS: This is an analytical cross-sectional study. Footage of 40 preterm infants was made in two views (lateral and anterior). The babies were placed in the supine position, with retroverted pelvis and semiflexed knees. Acrylic markers were positioned on surgical tape in eight predetermined anatomical points. We analyzed 4 variables in lateral view and 11 in anterior view (angular and linear) (ImageJ(®)), divided into two stages: 1. same frames - three blinded evaluators analyzed frames previously selected by the main researcher (inter-rater analysis 1), reviewing these same frames after 15 days (intra-rater analysis 1); 2. different frames - each evaluator selected the frames from the original video and repeated the protocol (inter-rater analysis 2), with a review after 15 days (intra-rater analysis 2). In stage 2, we tested the reliability of the entire process, from image selection to the analysis of variables. Data agreement and reproducibility were obtained by the intraclass correlation coefficient (ICC). RESULTS: Agreement was high, particularly in angular variables (ICC 0.82 to 0.99). Linear variables ranged between very good and excellent in analysis 1 (same frames: ICC 0.64 to 0.99) and analysis 2 (different frames: ICC 0.44 to 0.89). CONCLUSIONS: The present study suggests that the proposed protocol for the thoracoabdominal motion analysis of preterm neonates has high reliability. Sociedade de Pediatria de São Paulo 2020-12-07 /pmc/articles/PMC7724690/ /pubmed/33295596 http://dx.doi.org/10.1590/1984-0462/2021/39/2020034 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License |
spellingShingle | Original Article Campos, Juliana Vieira Moreno, Mariana Alves Silva, Ricardo de Bastos da Silva, Jessica Neves Quirino de Carvalho, Milena Ferreira dos Santos, Rayssa Christina Abreu Peres, Rodrigo Tosta Santos, Rosana da Silva Ferreira, Halina Cidrini INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT PROTOCOL FOR PRETERM INFANTS |
title | INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT
PROTOCOL FOR PRETERM INFANTS |
title_full | INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT
PROTOCOL FOR PRETERM INFANTS |
title_fullStr | INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT
PROTOCOL FOR PRETERM INFANTS |
title_full_unstemmed | INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT
PROTOCOL FOR PRETERM INFANTS |
title_short | INTRA- AND INTER-RATER RELIABILITY OF A BIOPHOTOGRAMMETRIC ASSESSMENT
PROTOCOL FOR PRETERM INFANTS |
title_sort | intra- and inter-rater reliability of a biophotogrammetric assessment
protocol for preterm infants |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724690/ https://www.ncbi.nlm.nih.gov/pubmed/33295596 http://dx.doi.org/10.1590/1984-0462/2021/39/2020034 |
work_keys_str_mv | AT camposjulianavieira intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants AT morenomarianaalves intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants AT silvaricardodebastos intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants AT dasilvajessicanevesquirino intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants AT decarvalhomilenaferreira intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants AT dossantosrayssachristinaabreu intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants AT peresrodrigotosta intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants AT santosrosanadasilva intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants AT ferreirahalinacidrini intraandinterraterreliabilityofabiophotogrammetricassessmentprotocolforpreterminfants |