Cargando…

Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis

BACKGROUND: Aseptic loosening of distal femoral tumor implants significantly correlates with the resection length. We designed a new “sleeve” that is specially engaged in the metaphysis at least 5 cm proximal to the knee joint line to preserve as much bone stock as possible. This study investigates...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jian-jun, Tian, Dong-mu, Yang, Li, Zhang, Jing-yu, Hu, Yong-cheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724731/
https://www.ncbi.nlm.nih.gov/pubmed/33298115
http://dx.doi.org/10.1186/s13018-020-02025-6
_version_ 1783620581649809408
author Li, Jian-jun
Tian, Dong-mu
Yang, Li
Zhang, Jing-yu
Hu, Yong-cheng
author_facet Li, Jian-jun
Tian, Dong-mu
Yang, Li
Zhang, Jing-yu
Hu, Yong-cheng
author_sort Li, Jian-jun
collection PubMed
description BACKGROUND: Aseptic loosening of distal femoral tumor implants significantly correlates with the resection length. We designed a new “sleeve” that is specially engaged in the metaphysis at least 5 cm proximal to the knee joint line to preserve as much bone stock as possible. This study investigates the influence of a metaphyseal sleeve on the stress-strain state of a bone tumor implant system in the distal femur. METHODS: Cortex strains in intact and implanted femurs were predicted with finite element (FE) models. Moreover strains were experimentally measured in a cadaveric femur with and without a sleeve and stem under an axial compressive load of 1000 N. The FE models, which were validated by linear regression, were used to investigate the maximal von Mises stress and the implanted-to-intact (ITI) ratios of strain in the femur with single-legged stance loading under immediate postoperative and osseointegration conditions. RESULTS: Good agreement was noted between the experimental measurements and numerical predictions of the femoral strains (coefficient of determination (R(2)) ≥ 0.95; root-mean-square error (RMSE%) ≈ 10%). The ITI ratios for the metaphysis were between 13 and 28% and between 10 and 21% under the immediate postoperative and osseointegration conditions, respectively, while the ITI ratios for the posterior and lateral cortices around the tip of the stem were 110% and 119% under the immediate-postoperative condition, respectively, and 114% and 101% under the osseointegration condition, respectively. The maximal von Mises stresses for the implanted femur were 113.8 MPa and 43.41 MPa under the immediate postoperative and osseointegration conditions, which were 284% and 47% higher than those in the intact femur (29.6 MPa), respectively. CONCLUSIONS: This study reveals that a metaphyseal sleeve may cause stress shielding relative to the intact femur, especially in the distal metaphysis. Stress concentrations might mainly occur in the posterior cortex around the tip of the stem. However, stress concentrations may not be accompanied by periprosthetic fracture under the single-legged stance condition.
format Online
Article
Text
id pubmed-7724731
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-77247312020-12-09 Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis Li, Jian-jun Tian, Dong-mu Yang, Li Zhang, Jing-yu Hu, Yong-cheng J Orthop Surg Res Research Article BACKGROUND: Aseptic loosening of distal femoral tumor implants significantly correlates with the resection length. We designed a new “sleeve” that is specially engaged in the metaphysis at least 5 cm proximal to the knee joint line to preserve as much bone stock as possible. This study investigates the influence of a metaphyseal sleeve on the stress-strain state of a bone tumor implant system in the distal femur. METHODS: Cortex strains in intact and implanted femurs were predicted with finite element (FE) models. Moreover strains were experimentally measured in a cadaveric femur with and without a sleeve and stem under an axial compressive load of 1000 N. The FE models, which were validated by linear regression, were used to investigate the maximal von Mises stress and the implanted-to-intact (ITI) ratios of strain in the femur with single-legged stance loading under immediate postoperative and osseointegration conditions. RESULTS: Good agreement was noted between the experimental measurements and numerical predictions of the femoral strains (coefficient of determination (R(2)) ≥ 0.95; root-mean-square error (RMSE%) ≈ 10%). The ITI ratios for the metaphysis were between 13 and 28% and between 10 and 21% under the immediate postoperative and osseointegration conditions, respectively, while the ITI ratios for the posterior and lateral cortices around the tip of the stem were 110% and 119% under the immediate-postoperative condition, respectively, and 114% and 101% under the osseointegration condition, respectively. The maximal von Mises stresses for the implanted femur were 113.8 MPa and 43.41 MPa under the immediate postoperative and osseointegration conditions, which were 284% and 47% higher than those in the intact femur (29.6 MPa), respectively. CONCLUSIONS: This study reveals that a metaphyseal sleeve may cause stress shielding relative to the intact femur, especially in the distal metaphysis. Stress concentrations might mainly occur in the posterior cortex around the tip of the stem. However, stress concentrations may not be accompanied by periprosthetic fracture under the single-legged stance condition. BioMed Central 2020-12-09 /pmc/articles/PMC7724731/ /pubmed/33298115 http://dx.doi.org/10.1186/s13018-020-02025-6 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Li, Jian-jun
Tian, Dong-mu
Yang, Li
Zhang, Jing-yu
Hu, Yong-cheng
Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis
title Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis
title_full Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis
title_fullStr Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis
title_full_unstemmed Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis
title_short Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis
title_sort influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7724731/
https://www.ncbi.nlm.nih.gov/pubmed/33298115
http://dx.doi.org/10.1186/s13018-020-02025-6
work_keys_str_mv AT lijianjun influenceofametaphysealsleeveonthestressstrainstateofabonetumorimplantsysteminthedistalfemuranexperimentalandfiniteelementanalysis
AT tiandongmu influenceofametaphysealsleeveonthestressstrainstateofabonetumorimplantsysteminthedistalfemuranexperimentalandfiniteelementanalysis
AT yangli influenceofametaphysealsleeveonthestressstrainstateofabonetumorimplantsysteminthedistalfemuranexperimentalandfiniteelementanalysis
AT zhangjingyu influenceofametaphysealsleeveonthestressstrainstateofabonetumorimplantsysteminthedistalfemuranexperimentalandfiniteelementanalysis
AT huyongcheng influenceofametaphysealsleeveonthestressstrainstateofabonetumorimplantsysteminthedistalfemuranexperimentalandfiniteelementanalysis