Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes
The purpose of this study was to evaluate the inter-device reliability of three VERT devices (Mayfonk Athletic, Florida, USA) when worn on the waist (W), left-hip (LH), and right-hip (RH) during single- and double-leg counter movement jumps (CMJ) in collegiate athletes. Thirty-two female and twenty-...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Institute of Sport in Warsaw
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7725037/ https://www.ncbi.nlm.nih.gov/pubmed/33343072 http://dx.doi.org/10.5114/biolsport.2020.96851 |
_version_ | 1783620630662348800 |
---|---|
author | Nickerson, Brett S. Medrano, Noel F. Perez, Gabriel L. Narvaez, Samantha V. Carrillo, Joshua Duque, Misael |
author_facet | Nickerson, Brett S. Medrano, Noel F. Perez, Gabriel L. Narvaez, Samantha V. Carrillo, Joshua Duque, Misael |
author_sort | Nickerson, Brett S. |
collection | PubMed |
description | The purpose of this study was to evaluate the inter-device reliability of three VERT devices (Mayfonk Athletic, Florida, USA) when worn on the waist (W), left-hip (LH), and right-hip (RH) during single- and double-leg counter movement jumps (CMJ) in collegiate athletes. Thirty-two female and twenty-eight male NCAA Division II athletes (n = 60) participated in the present study. Jump height (JH) values for double-leg CMJs were analyzed by each device using a one-way repeated measures ANOVA whereas a 2 (jump leg) x 3 (wear location) repeated measures ANOVA was employed to evaluate single-leg CMJs. Reliability of the VERT devices were based upon intraclass correlation coefficients (ICC). Double-leg CMJs revealed an excellent ICC between all three VERT devices (ICC = 0.969). However, JH for RH and LH (45.69 ± 9.84 and 45.82 ± 10.45 cm, respectively) were on average lower than W (50.44 ± 12.37cm; both p < 0.001). The ICCs were excellent for right- and left-leg CMJs (ICC = 0.939 and 0.941, respectively). However, an interaction was observed (p < 0.001). No differences existed for left- or right-leg when VERT was worn on the waist. However, JH was higher when VERT devices were worn on the opposite hip of the jump leg (i.e., LH>RH for right-leg CMJs; RH>LH for leftleg CMJs; all p < 0.001). Results suggest that LH and RH are interchangeable for double-leg CMJs, but not with waist despite excellent reliability. In addition, all wear locations provided excellent ICCs for single-leg CMJs. However, waist provides more consistent JH values for right- and left-leg CMJs while RH and LH show more variability. |
format | Online Article Text |
id | pubmed-7725037 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Institute of Sport in Warsaw |
record_format | MEDLINE/PubMed |
spelling | pubmed-77250372020-12-17 Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes Nickerson, Brett S. Medrano, Noel F. Perez, Gabriel L. Narvaez, Samantha V. Carrillo, Joshua Duque, Misael Biol Sport Original Paper The purpose of this study was to evaluate the inter-device reliability of three VERT devices (Mayfonk Athletic, Florida, USA) when worn on the waist (W), left-hip (LH), and right-hip (RH) during single- and double-leg counter movement jumps (CMJ) in collegiate athletes. Thirty-two female and twenty-eight male NCAA Division II athletes (n = 60) participated in the present study. Jump height (JH) values for double-leg CMJs were analyzed by each device using a one-way repeated measures ANOVA whereas a 2 (jump leg) x 3 (wear location) repeated measures ANOVA was employed to evaluate single-leg CMJs. Reliability of the VERT devices were based upon intraclass correlation coefficients (ICC). Double-leg CMJs revealed an excellent ICC between all three VERT devices (ICC = 0.969). However, JH for RH and LH (45.69 ± 9.84 and 45.82 ± 10.45 cm, respectively) were on average lower than W (50.44 ± 12.37cm; both p < 0.001). The ICCs were excellent for right- and left-leg CMJs (ICC = 0.939 and 0.941, respectively). However, an interaction was observed (p < 0.001). No differences existed for left- or right-leg when VERT was worn on the waist. However, JH was higher when VERT devices were worn on the opposite hip of the jump leg (i.e., LH>RH for right-leg CMJs; RH>LH for leftleg CMJs; all p < 0.001). Results suggest that LH and RH are interchangeable for double-leg CMJs, but not with waist despite excellent reliability. In addition, all wear locations provided excellent ICCs for single-leg CMJs. However, waist provides more consistent JH values for right- and left-leg CMJs while RH and LH show more variability. Institute of Sport in Warsaw 2020-07-05 2020-12 /pmc/articles/PMC7725037/ /pubmed/33343072 http://dx.doi.org/10.5114/biolsport.2020.96851 Text en Copyright © Biology of Sport 2020 http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Nickerson, Brett S. Medrano, Noel F. Perez, Gabriel L. Narvaez, Samantha V. Carrillo, Joshua Duque, Misael Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes |
title | Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes |
title_full | Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes |
title_fullStr | Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes |
title_full_unstemmed | Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes |
title_short | Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes |
title_sort | inter-device reliability of wearable technology for quantifying jump height in collegiate athletes |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7725037/ https://www.ncbi.nlm.nih.gov/pubmed/33343072 http://dx.doi.org/10.5114/biolsport.2020.96851 |
work_keys_str_mv | AT nickersonbretts interdevicereliabilityofwearabletechnologyforquantifyingjumpheightincollegiateathletes AT medranonoelf interdevicereliabilityofwearabletechnologyforquantifyingjumpheightincollegiateathletes AT perezgabriell interdevicereliabilityofwearabletechnologyforquantifyingjumpheightincollegiateathletes AT narvaezsamanthav interdevicereliabilityofwearabletechnologyforquantifyingjumpheightincollegiateathletes AT carrillojoshua interdevicereliabilityofwearabletechnologyforquantifyingjumpheightincollegiateathletes AT duquemisael interdevicereliabilityofwearabletechnologyforquantifyingjumpheightincollegiateathletes |