Cargando…

Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes

[Image: see text] We prepared the monomer PCDA-HP composed of 5-hydroxy-N(1),N(3)-bis(pyridin-2-ylmethyl)isophthalamide (HP) as a cadmium ion tweezer and then polymerized them to form a polydiacetylene (PDA)-based sensor (PDA-HP), which displayed selective and sensitive colorimetric and fluorometric...

Descripción completa

Detalles Bibliográficos
Autores principales: Pham, Thanh Chung, Lee, Seongman, Kim, Dongwon, Jung, Ok-Sang, Lee, Myung Won, Lee, Songyi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7726929/
https://www.ncbi.nlm.nih.gov/pubmed/33324835
http://dx.doi.org/10.1021/acsomega.0c04636
_version_ 1783620988651438080
author Pham, Thanh Chung
Lee, Seongman
Kim, Dongwon
Jung, Ok-Sang
Lee, Myung Won
Lee, Songyi
author_facet Pham, Thanh Chung
Lee, Seongman
Kim, Dongwon
Jung, Ok-Sang
Lee, Myung Won
Lee, Songyi
author_sort Pham, Thanh Chung
collection PubMed
description [Image: see text] We prepared the monomer PCDA-HP composed of 5-hydroxy-N(1),N(3)-bis(pyridin-2-ylmethyl)isophthalamide (HP) as a cadmium ion tweezer and then polymerized them to form a polydiacetylene (PDA)-based sensor (PDA-HP), which displayed selective and sensitive colorimetric and fluorometric change upon addition of a cadmium ion (Cd(2+)) at both pH 7.4 and 6.8. The PDA-HP polymer was highly selective for Cd(2+) over other metal ions with colorimetric change. In addition, the PDA-HP chemosensor also showed a red fluorescence change in the presence of Cd(2+) at both pH 7.4 and 6.8. Naked-eye detection of Cd(2+) was accomplished in an aqueous solution through a PDA-based sensor system. Finally, the lowest energy structure of an HP chelator was obtained by the crystal structure and density functional theory (DFT) calculations.
format Online
Article
Text
id pubmed-7726929
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-77269292020-12-14 Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes Pham, Thanh Chung Lee, Seongman Kim, Dongwon Jung, Ok-Sang Lee, Myung Won Lee, Songyi ACS Omega [Image: see text] We prepared the monomer PCDA-HP composed of 5-hydroxy-N(1),N(3)-bis(pyridin-2-ylmethyl)isophthalamide (HP) as a cadmium ion tweezer and then polymerized them to form a polydiacetylene (PDA)-based sensor (PDA-HP), which displayed selective and sensitive colorimetric and fluorometric change upon addition of a cadmium ion (Cd(2+)) at both pH 7.4 and 6.8. The PDA-HP polymer was highly selective for Cd(2+) over other metal ions with colorimetric change. In addition, the PDA-HP chemosensor also showed a red fluorescence change in the presence of Cd(2+) at both pH 7.4 and 6.8. Naked-eye detection of Cd(2+) was accomplished in an aqueous solution through a PDA-based sensor system. Finally, the lowest energy structure of an HP chelator was obtained by the crystal structure and density functional theory (DFT) calculations. American Chemical Society 2020-11-23 /pmc/articles/PMC7726929/ /pubmed/33324835 http://dx.doi.org/10.1021/acsomega.0c04636 Text en © 2020 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Pham, Thanh Chung
Lee, Seongman
Kim, Dongwon
Jung, Ok-Sang
Lee, Myung Won
Lee, Songyi
Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes
title Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes
title_full Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes
title_fullStr Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes
title_full_unstemmed Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes
title_short Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes
title_sort visual simultaneous detection and real-time monitoring of cadmium ions based on conjugated polydiacetylenes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7726929/
https://www.ncbi.nlm.nih.gov/pubmed/33324835
http://dx.doi.org/10.1021/acsomega.0c04636
work_keys_str_mv AT phamthanhchung visualsimultaneousdetectionandrealtimemonitoringofcadmiumionsbasedonconjugatedpolydiacetylenes
AT leeseongman visualsimultaneousdetectionandrealtimemonitoringofcadmiumionsbasedonconjugatedpolydiacetylenes
AT kimdongwon visualsimultaneousdetectionandrealtimemonitoringofcadmiumionsbasedonconjugatedpolydiacetylenes
AT jungoksang visualsimultaneousdetectionandrealtimemonitoringofcadmiumionsbasedonconjugatedpolydiacetylenes
AT leemyungwon visualsimultaneousdetectionandrealtimemonitoringofcadmiumionsbasedonconjugatedpolydiacetylenes
AT leesongyi visualsimultaneousdetectionandrealtimemonitoringofcadmiumionsbasedonconjugatedpolydiacetylenes