Cargando…
Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial
BACKGROUND: The American College of Surgeons reports 88,320 intraoperative needlestick injuries (NSIs) per year, resulting in US $376 to US $2456 in costs per NSI. Engineered sharps injury prevention (ESIP) devices protect against NSIs. To our knowledge, no study has been published to date to demons...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7728410/ https://www.ncbi.nlm.nih.gov/pubmed/33393914 http://dx.doi.org/10.2196/19729 |
_version_ | 1783621270647078912 |
---|---|
author | Jenny, Hillary Reategui Via y Rada, Maria Yesantharao, Pooja Xun, Helen Redett, Richard Sacks, Justin Michael Yang, Robin |
author_facet | Jenny, Hillary Reategui Via y Rada, Maria Yesantharao, Pooja Xun, Helen Redett, Richard Sacks, Justin Michael Yang, Robin |
author_sort | Jenny, Hillary |
collection | PubMed |
description | BACKGROUND: The American College of Surgeons reports 88,320 intraoperative needlestick injuries (NSIs) per year, resulting in US $376 to US $2456 in costs per NSI. Engineered sharps injury prevention (ESIP) devices protect against NSIs. To our knowledge, no study has been published to date to demonstrate clinical effectiveness of an intraoperative ESIP device. Operative Armour is a wearable arm cuff that can be donned during surgical closure to allow surgeons to keep a suture pack and sharps protection container on their forearm. OBJECTIVE: We characterize Operative Armour’s ESIP device effectiveness in a tertiary hospital, hypothesizing that this device will decrease NSI risk by decreasing behaviors associated with NSIs: needle passing and handling. METHODS: A prospective case-control study was conducted with institutional review board quality improvement designation in which authors observed skin closures of plastic surgery procedures. To ensure accuracy, one surgeon was observed at a time. Control surgeries were purely observational; intervention cases involved surgeon use of the device during skin closure. Outcomes of interest included needle passing, needle handling, lost needles, and loaded waiting needles. RESULTS: Surgeons were observed in 50 control and 50 intervention cases. Operative Armour eliminated needle passing during skin closure. One NSI occurred in one control case; no NSIs were observed in intervention cases (P=.36). The mean number of loaded and unprotected waiting needles was also significantly decreased in the intervention group from 2.3 to 0.2 (P<.001). Furthermore, a multivariable linear regression established that Operative Armour significantly decreased the number of needle adjustments by hand per stitch observed (F(4, 21.68)=3.72; P=.01). In fact, needle adjustments by hand decreased overall (1 adjustment per 10 stitches vs 1 adjustment per 5 stitches, P=.004), and adjustments occurred half as frequently with use of Operative Armour in free flap reconstruction (1 adjustment per 10 stitches vs 1 adjustment per 5 stitches, P=.03) and a quarter as frequently in other breast reconstruction cases such as mastopexy (1 adjustment per 20 stitches vs 1 adjustment per 5 stitches, P=.002). CONCLUSIONS: Operative Armour effectively functions as an ESIP device by decreasing intraoperative needle passing and handling. Although sample size prohibits demonstrating a decrease in NSIs during observed cases, by decreasing behaviors that drive NSI risk, we anticipate an associated decrease in NSIs with use of the device. |
format | Online Article Text |
id | pubmed-7728410 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-77284102020-12-17 Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial Jenny, Hillary Reategui Via y Rada, Maria Yesantharao, Pooja Xun, Helen Redett, Richard Sacks, Justin Michael Yang, Robin JMIR Perioper Med Original Paper BACKGROUND: The American College of Surgeons reports 88,320 intraoperative needlestick injuries (NSIs) per year, resulting in US $376 to US $2456 in costs per NSI. Engineered sharps injury prevention (ESIP) devices protect against NSIs. To our knowledge, no study has been published to date to demonstrate clinical effectiveness of an intraoperative ESIP device. Operative Armour is a wearable arm cuff that can be donned during surgical closure to allow surgeons to keep a suture pack and sharps protection container on their forearm. OBJECTIVE: We characterize Operative Armour’s ESIP device effectiveness in a tertiary hospital, hypothesizing that this device will decrease NSI risk by decreasing behaviors associated with NSIs: needle passing and handling. METHODS: A prospective case-control study was conducted with institutional review board quality improvement designation in which authors observed skin closures of plastic surgery procedures. To ensure accuracy, one surgeon was observed at a time. Control surgeries were purely observational; intervention cases involved surgeon use of the device during skin closure. Outcomes of interest included needle passing, needle handling, lost needles, and loaded waiting needles. RESULTS: Surgeons were observed in 50 control and 50 intervention cases. Operative Armour eliminated needle passing during skin closure. One NSI occurred in one control case; no NSIs were observed in intervention cases (P=.36). The mean number of loaded and unprotected waiting needles was also significantly decreased in the intervention group from 2.3 to 0.2 (P<.001). Furthermore, a multivariable linear regression established that Operative Armour significantly decreased the number of needle adjustments by hand per stitch observed (F(4, 21.68)=3.72; P=.01). In fact, needle adjustments by hand decreased overall (1 adjustment per 10 stitches vs 1 adjustment per 5 stitches, P=.004), and adjustments occurred half as frequently with use of Operative Armour in free flap reconstruction (1 adjustment per 10 stitches vs 1 adjustment per 5 stitches, P=.03) and a quarter as frequently in other breast reconstruction cases such as mastopexy (1 adjustment per 20 stitches vs 1 adjustment per 5 stitches, P=.002). CONCLUSIONS: Operative Armour effectively functions as an ESIP device by decreasing intraoperative needle passing and handling. Although sample size prohibits demonstrating a decrease in NSIs during observed cases, by decreasing behaviors that drive NSI risk, we anticipate an associated decrease in NSIs with use of the device. JMIR Publications 2020-11-27 /pmc/articles/PMC7728410/ /pubmed/33393914 http://dx.doi.org/10.2196/19729 Text en ©Hillary Jenny, Maria Reategui Via y Rada, Pooja Yesantharao, Helen Xun, Richard Redett, Justin Michael Sacks, Robin Yang. Originally published in JMIR Perioperative Medicine (http://periop.jmir.org), 27.11.2020. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Perioperative Medicine, is properly cited. The complete bibliographic information, a link to the original publication on http://periop.jmir.org, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Jenny, Hillary Reategui Via y Rada, Maria Yesantharao, Pooja Xun, Helen Redett, Richard Sacks, Justin Michael Yang, Robin Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial |
title | Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial |
title_full | Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial |
title_fullStr | Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial |
title_full_unstemmed | Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial |
title_short | Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial |
title_sort | efficacy of a novel intraoperative engineered sharps injury prevention device: pilot usability and efficacy trial |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7728410/ https://www.ncbi.nlm.nih.gov/pubmed/33393914 http://dx.doi.org/10.2196/19729 |
work_keys_str_mv | AT jennyhillary efficacyofanovelintraoperativeengineeredsharpsinjurypreventiondevicepilotusabilityandefficacytrial AT reateguiviayradamaria efficacyofanovelintraoperativeengineeredsharpsinjurypreventiondevicepilotusabilityandefficacytrial AT yesantharaopooja efficacyofanovelintraoperativeengineeredsharpsinjurypreventiondevicepilotusabilityandefficacytrial AT xunhelen efficacyofanovelintraoperativeengineeredsharpsinjurypreventiondevicepilotusabilityandefficacytrial AT redettrichard efficacyofanovelintraoperativeengineeredsharpsinjurypreventiondevicepilotusabilityandefficacytrial AT sacksjustinmichael efficacyofanovelintraoperativeengineeredsharpsinjurypreventiondevicepilotusabilityandefficacytrial AT yangrobin efficacyofanovelintraoperativeengineeredsharpsinjurypreventiondevicepilotusabilityandefficacytrial |