Cargando…

Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach

The posterolateral tibial plateau fracture was not easy to be exposed and fixed with usual techniques. The aim of this study was to investigate the biomechanical stability and clinical outcome of the isolated posterolateral tibial plateau fracture fixed with a single horizontal belt plate through th...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Sunjun, Chen, Shiyi, Chang, Shimin, Xiong, Wenfeng, Tuladhar, Rujan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7728474/
https://www.ncbi.nlm.nih.gov/pubmed/33344635
http://dx.doi.org/10.1155/2020/4186712
_version_ 1783621282888155136
author Hu, Sunjun
Chen, Shiyi
Chang, Shimin
Xiong, Wenfeng
Tuladhar, Rujan
author_facet Hu, Sunjun
Chen, Shiyi
Chang, Shimin
Xiong, Wenfeng
Tuladhar, Rujan
author_sort Hu, Sunjun
collection PubMed
description The posterolateral tibial plateau fracture was not easy to be exposed and fixed with usual techniques. The aim of this study was to investigate the biomechanical stability and clinical outcome of the isolated posterolateral tibial plateau fracture fixed with a single horizontal belt plate through the anterolateral supra-fibular-head approach. Fracture models were created by 18 synthetic tibias and fixed with three different fixation modes. Each group was fixed and tested on the loading machine, and final vertical displacement of the fragment was detected and calculated. Clinically, a retrospective analysis of 12 cases of posterolateral tibial plateau fracture from January 2013 to December 2017 was performed. There were 8 males and 4 females, aged 33-72 years, with an average age of 49.6 years. Isolated posterolateral tibial plateau fractures were identified according to preoperative X-ray and computed tomography scan. Through the modified anterolateral supra-fibular-head approach, the fracture was reduced and fixed by a prebending T-shaped distal radius plate and rafting screws, with bone substitute grafting or autogenous iliac bone implantation. Patients were followed up to a minimum one year of time period, and the outcome was evaluated clinically and radiologically. The biomechanical study shows that horizontal belt plate fixation for the isolated PL tibial plateau fracture can provide sufficient stability, allowing early knee functional exercise and partial weight bearing. For clinical case series, the average operation time in this group was 73.3 ± 10.2 mins (range: 55-90), and the average duration of hospitalization was 9.1 ± 3.3 days (range: 5-16). Patients were followed up for 12-24 months with an average of 16.5 months, and all patients achieved radiological fracture union after an average of 13.7 weeks. At one year after operation, the average knee score of the Hospital for Special Surgery (HSS) scale was 93.2 ± 4.2 points(range: 90-98), the average score of SMFA was 21.1 ± 5.6 points (range: 14-31), and the average knee range of motion (ROM) was 121.48° ± 8.88° (range: 105°-135°). There were 8 cases that were very satisfied and 3 cases that were satisfied with the operation. For an isolated posterolateral tibial plateau fracture, the supra-fibular-head approach can fully expose the fracture site; the horizontal belt plate fixation of the fracture is stable and reliable to allow for early-stage knee rehabilitation, and the outcome of medium-term clinical follow-up was satisfactory.
format Online
Article
Text
id pubmed-7728474
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-77284742020-12-17 Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach Hu, Sunjun Chen, Shiyi Chang, Shimin Xiong, Wenfeng Tuladhar, Rujan Biomed Res Int Research Article The posterolateral tibial plateau fracture was not easy to be exposed and fixed with usual techniques. The aim of this study was to investigate the biomechanical stability and clinical outcome of the isolated posterolateral tibial plateau fracture fixed with a single horizontal belt plate through the anterolateral supra-fibular-head approach. Fracture models were created by 18 synthetic tibias and fixed with three different fixation modes. Each group was fixed and tested on the loading machine, and final vertical displacement of the fragment was detected and calculated. Clinically, a retrospective analysis of 12 cases of posterolateral tibial plateau fracture from January 2013 to December 2017 was performed. There were 8 males and 4 females, aged 33-72 years, with an average age of 49.6 years. Isolated posterolateral tibial plateau fractures were identified according to preoperative X-ray and computed tomography scan. Through the modified anterolateral supra-fibular-head approach, the fracture was reduced and fixed by a prebending T-shaped distal radius plate and rafting screws, with bone substitute grafting or autogenous iliac bone implantation. Patients were followed up to a minimum one year of time period, and the outcome was evaluated clinically and radiologically. The biomechanical study shows that horizontal belt plate fixation for the isolated PL tibial plateau fracture can provide sufficient stability, allowing early knee functional exercise and partial weight bearing. For clinical case series, the average operation time in this group was 73.3 ± 10.2 mins (range: 55-90), and the average duration of hospitalization was 9.1 ± 3.3 days (range: 5-16). Patients were followed up for 12-24 months with an average of 16.5 months, and all patients achieved radiological fracture union after an average of 13.7 weeks. At one year after operation, the average knee score of the Hospital for Special Surgery (HSS) scale was 93.2 ± 4.2 points(range: 90-98), the average score of SMFA was 21.1 ± 5.6 points (range: 14-31), and the average knee range of motion (ROM) was 121.48° ± 8.88° (range: 105°-135°). There were 8 cases that were very satisfied and 3 cases that were satisfied with the operation. For an isolated posterolateral tibial plateau fracture, the supra-fibular-head approach can fully expose the fracture site; the horizontal belt plate fixation of the fracture is stable and reliable to allow for early-stage knee rehabilitation, and the outcome of medium-term clinical follow-up was satisfactory. Hindawi 2020-12-03 /pmc/articles/PMC7728474/ /pubmed/33344635 http://dx.doi.org/10.1155/2020/4186712 Text en Copyright © 2020 Sunjun Hu et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hu, Sunjun
Chen, Shiyi
Chang, Shimin
Xiong, Wenfeng
Tuladhar, Rujan
Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach
title Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach
title_full Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach
title_fullStr Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach
title_full_unstemmed Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach
title_short Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach
title_sort treatment of isolated posterolateral tibial plateau fracture with a horizontal belt plate through the anterolateral supra-fibular-head approach
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7728474/
https://www.ncbi.nlm.nih.gov/pubmed/33344635
http://dx.doi.org/10.1155/2020/4186712
work_keys_str_mv AT husunjun treatmentofisolatedposterolateraltibialplateaufracturewithahorizontalbeltplatethroughtheanterolateralsuprafibularheadapproach
AT chenshiyi treatmentofisolatedposterolateraltibialplateaufracturewithahorizontalbeltplatethroughtheanterolateralsuprafibularheadapproach
AT changshimin treatmentofisolatedposterolateraltibialplateaufracturewithahorizontalbeltplatethroughtheanterolateralsuprafibularheadapproach
AT xiongwenfeng treatmentofisolatedposterolateraltibialplateaufracturewithahorizontalbeltplatethroughtheanterolateralsuprafibularheadapproach
AT tuladharrujan treatmentofisolatedposterolateraltibialplateaufracturewithahorizontalbeltplatethroughtheanterolateralsuprafibularheadapproach