Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

BACKGROUND: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Kyung Chun, Kim, Doo Hyun, Kim, Sung Chul, Kim, Jae Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Occupational Safety and Health Research Institute 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7728825/
https://www.ncbi.nlm.nih.gov/pubmed/33329906
http://dx.doi.org/10.1016/j.shaw.2020.06.004
_version_ 1783621355640455168
author Kim, Kyung Chun
Kim, Doo Hyun
Kim, Sung Chul
Kim, Jae Ho
author_facet Kim, Kyung Chun
Kim, Doo Hyun
Kim, Sung Chul
Kim, Jae Ho
author_sort Kim, Kyung Chun
collection PubMed
description BACKGROUND: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. METHODS: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets’ conductor surface and content, insulator weight, and thermal deformation temperature. RESULTS: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 °C. In relation to the installation year (30 years), insulation resistance decreased from 70 °C, which is as much as 40 °C lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. CONCLUSION: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 °C of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 °C. It is necessary to manage electrical socket outlets that have been installed for a long time.
format Online
Article
Text
id pubmed-7728825
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Occupational Safety and Health Research Institute
record_format MEDLINE/PubMed
spelling pubmed-77288252020-12-15 Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets Kim, Kyung Chun Kim, Doo Hyun Kim, Sung Chul Kim, Jae Ho Saf Health Work Original Article BACKGROUND: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. METHODS: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets’ conductor surface and content, insulator weight, and thermal deformation temperature. RESULTS: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 °C. In relation to the installation year (30 years), insulation resistance decreased from 70 °C, which is as much as 40 °C lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. CONCLUSION: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 °C of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 °C. It is necessary to manage electrical socket outlets that have been installed for a long time. Occupational Safety and Health Research Institute 2020-12 2020-06-30 /pmc/articles/PMC7728825/ /pubmed/33329906 http://dx.doi.org/10.1016/j.shaw.2020.06.004 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Kim, Kyung Chun
Kim, Doo Hyun
Kim, Sung Chul
Kim, Jae Ho
Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets
title Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets
title_full Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets
title_fullStr Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets
title_full_unstemmed Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets
title_short Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets
title_sort analysis of thermal characteristics and insulation resistance based on the installation year and accelerated test by electrical socket outlets
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7728825/
https://www.ncbi.nlm.nih.gov/pubmed/33329906
http://dx.doi.org/10.1016/j.shaw.2020.06.004
work_keys_str_mv AT kimkyungchun analysisofthermalcharacteristicsandinsulationresistancebasedontheinstallationyearandacceleratedtestbyelectricalsocketoutlets
AT kimdoohyun analysisofthermalcharacteristicsandinsulationresistancebasedontheinstallationyearandacceleratedtestbyelectricalsocketoutlets
AT kimsungchul analysisofthermalcharacteristicsandinsulationresistancebasedontheinstallationyearandacceleratedtestbyelectricalsocketoutlets
AT kimjaeho analysisofthermalcharacteristicsandinsulationresistancebasedontheinstallationyearandacceleratedtestbyelectricalsocketoutlets