Cargando…

An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module

BACKGROUND: In this experimental study, we evaluated the use of digital 3D navigation printing in minimizing complications arising from sacroiliac screw misplacement. METHODS: A total of 13 adult pelvic specimens were studied using 3D navigation printing. Mimics software was used for preoperative pl...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Xuanhuang, Zheng, Feng, Zhang, Guodong, Gao, Xiaoqiang, Wang, Ya, Huang, Wenhua, Lin, Haibin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7729361/
https://www.ncbi.nlm.nih.gov/pubmed/33313257
http://dx.doi.org/10.21037/atm-20-7080
_version_ 1783621440966230016
author Chen, Xuanhuang
Zheng, Feng
Zhang, Guodong
Gao, Xiaoqiang
Wang, Ya
Huang, Wenhua
Lin, Haibin
author_facet Chen, Xuanhuang
Zheng, Feng
Zhang, Guodong
Gao, Xiaoqiang
Wang, Ya
Huang, Wenhua
Lin, Haibin
author_sort Chen, Xuanhuang
collection PubMed
description BACKGROUND: In this experimental study, we evaluated the use of digital 3D navigation printing in minimizing complications arising from sacroiliac screw misplacement. METHODS: A total of 13 adult pelvic specimens were studied using 3D navigation printing. Mimics software was used for preoperative planning and for obtaining sacrum median sagittal resection and long axis resection of the S1 pedicle center by 3D segmentation. The ideal screw path had its origin at the post-median part of the auricular surface of the sacroiliac joint, the midpoint at the mid-position of the lateral recess and outlet of the anterior sacral foramina; and the endpoint at the S1 sagittal resection. A sacroiliac screw fixed the pelvic specimens with the assistance of the navigation module. The distance between the start point (ilium surface) and endpoint (sacral median sagittal resection) of the screw path was measured after the pre- and postoperative 3D pelvis module was 3D-registered according to the standard precision range. The origin/endpoint qualified rates of the postoperative (n/26) and preoperative (26/26) screw paths were analyzed by the chi-square test. RESULTS: No screw misplacement occurred in the screw paths of any of the 13 pelvic specimens. The mean distance between the preoperative and postoperative origin of the screw path was 1.5415±0.6806 mm, and the mean distance between the preoperative and postoperative endpoint was 2.2809±0.4855 mm. The qualified rate of origin was 23/26 when the precision grade was 2.4 mm (P>0.05, χ(2)=1.41), while the qualified rate of endpoint was 21/26 when the precision grade was 2.7 mm (P>0.05, χ(2)=3.54). CONCLUSIONS: In this experimental study, using a 3D printing navigation module helped attain an accurate and safe sacroiliac screw implantation.
format Online
Article
Text
id pubmed-7729361
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-77293612020-12-11 An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module Chen, Xuanhuang Zheng, Feng Zhang, Guodong Gao, Xiaoqiang Wang, Ya Huang, Wenhua Lin, Haibin Ann Transl Med Original Article BACKGROUND: In this experimental study, we evaluated the use of digital 3D navigation printing in minimizing complications arising from sacroiliac screw misplacement. METHODS: A total of 13 adult pelvic specimens were studied using 3D navigation printing. Mimics software was used for preoperative planning and for obtaining sacrum median sagittal resection and long axis resection of the S1 pedicle center by 3D segmentation. The ideal screw path had its origin at the post-median part of the auricular surface of the sacroiliac joint, the midpoint at the mid-position of the lateral recess and outlet of the anterior sacral foramina; and the endpoint at the S1 sagittal resection. A sacroiliac screw fixed the pelvic specimens with the assistance of the navigation module. The distance between the start point (ilium surface) and endpoint (sacral median sagittal resection) of the screw path was measured after the pre- and postoperative 3D pelvis module was 3D-registered according to the standard precision range. The origin/endpoint qualified rates of the postoperative (n/26) and preoperative (26/26) screw paths were analyzed by the chi-square test. RESULTS: No screw misplacement occurred in the screw paths of any of the 13 pelvic specimens. The mean distance between the preoperative and postoperative origin of the screw path was 1.5415±0.6806 mm, and the mean distance between the preoperative and postoperative endpoint was 2.2809±0.4855 mm. The qualified rate of origin was 23/26 when the precision grade was 2.4 mm (P>0.05, χ(2)=1.41), while the qualified rate of endpoint was 21/26 when the precision grade was 2.7 mm (P>0.05, χ(2)=3.54). CONCLUSIONS: In this experimental study, using a 3D printing navigation module helped attain an accurate and safe sacroiliac screw implantation. AME Publishing Company 2020-11 /pmc/articles/PMC7729361/ /pubmed/33313257 http://dx.doi.org/10.21037/atm-20-7080 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Chen, Xuanhuang
Zheng, Feng
Zhang, Guodong
Gao, Xiaoqiang
Wang, Ya
Huang, Wenhua
Lin, Haibin
An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
title An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
title_full An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
title_fullStr An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
title_full_unstemmed An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
title_short An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
title_sort experimental study on the safe placement of sacroiliac screws using a 3d printing navigation module
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7729361/
https://www.ncbi.nlm.nih.gov/pubmed/33313257
http://dx.doi.org/10.21037/atm-20-7080
work_keys_str_mv AT chenxuanhuang anexperimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT zhengfeng anexperimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT zhangguodong anexperimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT gaoxiaoqiang anexperimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT wangya anexperimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT huangwenhua anexperimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT linhaibin anexperimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT chenxuanhuang experimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT zhengfeng experimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT zhangguodong experimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT gaoxiaoqiang experimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT wangya experimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT huangwenhua experimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule
AT linhaibin experimentalstudyonthesafeplacementofsacroiliacscrewsusinga3dprintingnavigationmodule