Cargando…

The effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions

BACKGROUND: To analyze the application values of quantitative parametrics measured by three-dimensional transvaginal sonography (3D-TVS) in the diagnosis of uterine cavity distortions. METHODS: A retrospective analysis was performed on consecutive 113 patients with septate uteruses, as diagnosed con...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Yan, Liu, Min, He, Suhui, Yang, Minmin, Wu, Qiumei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7729365/
https://www.ncbi.nlm.nih.gov/pubmed/33313231
http://dx.doi.org/10.21037/atm-20-6755
_version_ 1783621441930919936
author Lin, Yan
Liu, Min
He, Suhui
Yang, Minmin
Wu, Qiumei
author_facet Lin, Yan
Liu, Min
He, Suhui
Yang, Minmin
Wu, Qiumei
author_sort Lin, Yan
collection PubMed
description BACKGROUND: To analyze the application values of quantitative parametrics measured by three-dimensional transvaginal sonography (3D-TVS) in the diagnosis of uterine cavity distortions. METHODS: A retrospective analysis was performed on consecutive 113 patients with septate uteruses, as diagnosed consistently by both 3D-TVS and hysteroscopic surgery, between Jan 2016 and Jan 2018. The intrauterine quantitative parametrics were compared between an infertility group and a miscarriage group. Receiver operating characteristic (ROC) curve analysis and evaluation indicators of diagnostic tests were plotted to analyze the relationships between parametrics and uterine cavity distortions. RESULTS: There were no significant differences in septum width, septum length, uterine angle, remaining uterine cavity length, and distortion rate between the infertility and miscarriage groups (P>0.05). The distortion rate was positively correlated with septum length, but showed a negative correlation with uterine angle and remaining uterine cavity length (all P<0.05). The area under the curve (AUC) of septum length for predicting a distortion rate higher than 50% was 0.969; with a cutoff value of 2.15 cm, and a diagnostic accuracy of 97.14%, sensitivity was 81.80% and specificity was 98.90%, respectively. Patients with lower septum length coupled with a higher remaining uterine cavity length had a lower risk of uterine cavity distortion. CONCLUSIONS: Septum length was shown to have the most important effect on uterine cavity distortion of all the uterine parametrics measured by 3D-TVS. Patients with septum lengths higher than 2.15 cm indicated a distortion rate of more than 50%, and tend to experience adverse pregnancy outcomes.
format Online
Article
Text
id pubmed-7729365
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-77293652020-12-11 The effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions Lin, Yan Liu, Min He, Suhui Yang, Minmin Wu, Qiumei Ann Transl Med Original Article BACKGROUND: To analyze the application values of quantitative parametrics measured by three-dimensional transvaginal sonography (3D-TVS) in the diagnosis of uterine cavity distortions. METHODS: A retrospective analysis was performed on consecutive 113 patients with septate uteruses, as diagnosed consistently by both 3D-TVS and hysteroscopic surgery, between Jan 2016 and Jan 2018. The intrauterine quantitative parametrics were compared between an infertility group and a miscarriage group. Receiver operating characteristic (ROC) curve analysis and evaluation indicators of diagnostic tests were plotted to analyze the relationships between parametrics and uterine cavity distortions. RESULTS: There were no significant differences in septum width, septum length, uterine angle, remaining uterine cavity length, and distortion rate between the infertility and miscarriage groups (P>0.05). The distortion rate was positively correlated with septum length, but showed a negative correlation with uterine angle and remaining uterine cavity length (all P<0.05). The area under the curve (AUC) of septum length for predicting a distortion rate higher than 50% was 0.969; with a cutoff value of 2.15 cm, and a diagnostic accuracy of 97.14%, sensitivity was 81.80% and specificity was 98.90%, respectively. Patients with lower septum length coupled with a higher remaining uterine cavity length had a lower risk of uterine cavity distortion. CONCLUSIONS: Septum length was shown to have the most important effect on uterine cavity distortion of all the uterine parametrics measured by 3D-TVS. Patients with septum lengths higher than 2.15 cm indicated a distortion rate of more than 50%, and tend to experience adverse pregnancy outcomes. AME Publishing Company 2020-11 /pmc/articles/PMC7729365/ /pubmed/33313231 http://dx.doi.org/10.21037/atm-20-6755 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Lin, Yan
Liu, Min
He, Suhui
Yang, Minmin
Wu, Qiumei
The effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions
title The effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions
title_full The effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions
title_fullStr The effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions
title_full_unstemmed The effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions
title_short The effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions
title_sort effectiveness of uterine parametrics measured by three-dimensional transvaginal sonography in the diagnosis of uterine cavity distortions
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7729365/
https://www.ncbi.nlm.nih.gov/pubmed/33313231
http://dx.doi.org/10.21037/atm-20-6755
work_keys_str_mv AT linyan theeffectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT liumin theeffectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT hesuhui theeffectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT yangminmin theeffectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT wuqiumei theeffectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT linyan effectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT liumin effectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT hesuhui effectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT yangminmin effectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions
AT wuqiumei effectivenessofuterineparametricsmeasuredbythreedimensionaltransvaginalsonographyinthediagnosisofuterinecavitydistortions