Cargando…
Microwave Staring Correlated Imaging Method Based on Steady Radiation Fields Sequence
Microwave Staring Correlated Imaging (MSCI) is a newly proposed computational high-resolution imaging technique. The imaging performance of MSCI with the existence of modeling errors depends on the properties of the imaging matrix and the relative perturbation error resulted from existing errors. In...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7729987/ https://www.ncbi.nlm.nih.gov/pubmed/33266182 http://dx.doi.org/10.3390/s20236859 |
_version_ | 1783621583083929600 |
---|---|
author | Zhang, Jianlin Yuan, Bo Jiang, Zheng Guo, Yuanyue Wang, Dongjin |
author_facet | Zhang, Jianlin Yuan, Bo Jiang, Zheng Guo, Yuanyue Wang, Dongjin |
author_sort | Zhang, Jianlin |
collection | PubMed |
description | Microwave Staring Correlated Imaging (MSCI) is a newly proposed computational high-resolution imaging technique. The imaging performance of MSCI with the existence of modeling errors depends on the properties of the imaging matrix and the relative perturbation error resulted from existing errors. In conventional transient-radiation-fields-based MSCI, which is commonly accomplished by utilizing random frequency-hopping (FH) waveforms, the multiple transmitters should be controlled individually and simultaneously. System complexity and control difficulty are hence increased, and various types of modeling errors are introduced as well. The computation accuracy of radiation fields is heavily worsened by the modeling errors, and the transient effect makes it hard to take direct and high-precision measurements of the radiation fields and calibrate the modeling errors with the measuring result. To simplify the system complexity and reduce error sources, in this paper, steady-radiation-fields-sequence-based MSCI (SRFS-MSCI) method is proposed. The multiple transmitters are excited with coherent signals at the same observation moment, with the signal frequency varying in the whole frequency band during the imaging process. By elaborately designing the array configuration and the amplitude and phase sequences of the coherent transmitters, the SRFS-MSCI is thus implemented. Comparing the system architecture of the proposed SRFS-MSCI with the conventional random FH-based MSCI, it can be found that the proposed method significantly reduces the number of baseband modules and simplifies the system architecture and control logic, which contributes to reducing error sources such as baseband synchronization errors and decreasing deterioration caused by error cascade. To further optimize the design parameters in the proposed SRFS-MSCI system, the Simulated Annealing (SA) algorithm is utilized to optimize the amplitude sequences, the phase sequences, and the antenna positions individually and jointly. Numerical imaging experiments and real-world imaging experiment demonstrate the effectiveness of the proposed SRFS-MSCI method that recognizable high-resolution recovery results are obtained with simplified system structure and optimized system parameters. |
format | Online Article Text |
id | pubmed-7729987 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77299872020-12-12 Microwave Staring Correlated Imaging Method Based on Steady Radiation Fields Sequence Zhang, Jianlin Yuan, Bo Jiang, Zheng Guo, Yuanyue Wang, Dongjin Sensors (Basel) Letter Microwave Staring Correlated Imaging (MSCI) is a newly proposed computational high-resolution imaging technique. The imaging performance of MSCI with the existence of modeling errors depends on the properties of the imaging matrix and the relative perturbation error resulted from existing errors. In conventional transient-radiation-fields-based MSCI, which is commonly accomplished by utilizing random frequency-hopping (FH) waveforms, the multiple transmitters should be controlled individually and simultaneously. System complexity and control difficulty are hence increased, and various types of modeling errors are introduced as well. The computation accuracy of radiation fields is heavily worsened by the modeling errors, and the transient effect makes it hard to take direct and high-precision measurements of the radiation fields and calibrate the modeling errors with the measuring result. To simplify the system complexity and reduce error sources, in this paper, steady-radiation-fields-sequence-based MSCI (SRFS-MSCI) method is proposed. The multiple transmitters are excited with coherent signals at the same observation moment, with the signal frequency varying in the whole frequency band during the imaging process. By elaborately designing the array configuration and the amplitude and phase sequences of the coherent transmitters, the SRFS-MSCI is thus implemented. Comparing the system architecture of the proposed SRFS-MSCI with the conventional random FH-based MSCI, it can be found that the proposed method significantly reduces the number of baseband modules and simplifies the system architecture and control logic, which contributes to reducing error sources such as baseband synchronization errors and decreasing deterioration caused by error cascade. To further optimize the design parameters in the proposed SRFS-MSCI system, the Simulated Annealing (SA) algorithm is utilized to optimize the amplitude sequences, the phase sequences, and the antenna positions individually and jointly. Numerical imaging experiments and real-world imaging experiment demonstrate the effectiveness of the proposed SRFS-MSCI method that recognizable high-resolution recovery results are obtained with simplified system structure and optimized system parameters. MDPI 2020-11-30 /pmc/articles/PMC7729987/ /pubmed/33266182 http://dx.doi.org/10.3390/s20236859 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Letter Zhang, Jianlin Yuan, Bo Jiang, Zheng Guo, Yuanyue Wang, Dongjin Microwave Staring Correlated Imaging Method Based on Steady Radiation Fields Sequence |
title | Microwave Staring Correlated Imaging Method Based on Steady Radiation Fields Sequence |
title_full | Microwave Staring Correlated Imaging Method Based on Steady Radiation Fields Sequence |
title_fullStr | Microwave Staring Correlated Imaging Method Based on Steady Radiation Fields Sequence |
title_full_unstemmed | Microwave Staring Correlated Imaging Method Based on Steady Radiation Fields Sequence |
title_short | Microwave Staring Correlated Imaging Method Based on Steady Radiation Fields Sequence |
title_sort | microwave staring correlated imaging method based on steady radiation fields sequence |
topic | Letter |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7729987/ https://www.ncbi.nlm.nih.gov/pubmed/33266182 http://dx.doi.org/10.3390/s20236859 |
work_keys_str_mv | AT zhangjianlin microwavestaringcorrelatedimagingmethodbasedonsteadyradiationfieldssequence AT yuanbo microwavestaringcorrelatedimagingmethodbasedonsteadyradiationfieldssequence AT jiangzheng microwavestaringcorrelatedimagingmethodbasedonsteadyradiationfieldssequence AT guoyuanyue microwavestaringcorrelatedimagingmethodbasedonsteadyradiationfieldssequence AT wangdongjin microwavestaringcorrelatedimagingmethodbasedonsteadyradiationfieldssequence |