Optimal Design of Annular Phased Array Transducers for Material Nonlinearity Determination in Pulse–Echo Ultrasonic Testing
Nonlinear ultrasound has been proven to be a useful nondestructive testing tool for micro-damage inspection of materials and structures operating in harsh environment. When measuring the nonlinear second harmonic wave in a solid specimen in the pulse–echo (PE) testing mode, the stress-free boundary...
Autores principales: | Cho, Sungjong, Jeong, Hyunjo, Park, Ik Keun |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7730178/ https://www.ncbi.nlm.nih.gov/pubmed/33291342 http://dx.doi.org/10.3390/ma13235565 |
Ejemplares similares
-
Application of Fresnel Zone Plate Focused Beam to Optimized Sensor Design for Pulse-Echo Harmonic Generation Measurements
por: Jeong, Hyunjo, et al.
Publicado: (2019) -
Absolute Measurement of Material Nonlinear Parameters Using Noncontact Air-Coupled Reception
por: Jeong, Hyunjo, et al.
Publicado: (2021) -
Analysis of Flaw Detection Sensitivity of Phased Array Ultrasonics in Austenitic Steel Welds According to Inspection Conditions
por: Kim, YoungLae, et al.
Publicado: (2021) -
Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation
por: Jeong, Hyunjo, et al.
Publicado: (2023) -
Characterizing Microstructural Evolution of TP304 Stainless Steel Using a Pulse-Echo Nonlinear Method
por: Liu, Yichen, et al.
Publicado: (2020)