Cargando…

Effects of Loaded End Distance and Moisture Content on the Behavior of Bolted Connections in Squared and Round Timber Subjected to Tension Parallel to the Grain

This article presents the results of static tests on bolted connections in squared and round timber with inserted steel plates. The experiment evaluates structural timber connections with different distances between the fastener and the loaded end at different moisture contents. Specimens were loade...

Descripción completa

Detalles Bibliográficos
Autores principales: Lokaj, Antonin, Dobes, Pavel, Sucharda, Oldrich
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7731337/
https://www.ncbi.nlm.nih.gov/pubmed/33287370
http://dx.doi.org/10.3390/ma13235525
_version_ 1783621879367467008
author Lokaj, Antonin
Dobes, Pavel
Sucharda, Oldrich
author_facet Lokaj, Antonin
Dobes, Pavel
Sucharda, Oldrich
author_sort Lokaj, Antonin
collection PubMed
description This article presents the results of static tests on bolted connections in squared and round timber with inserted steel plates. The experiment evaluates structural timber connections with different distances between the fastener and the loaded end at different moisture contents. Specimens were loaded by tension parallel to the grain and load–deformation diagrams were recorded. Fifty-six specimens with three different distances between the fastener and the loaded end, at different moisture contents, were tested. The results were statistically evaluated using regression analysis, complemented with load–deformation curves, and compared with calculations according to the valid standard for design of timber structures. A decrease in the evaluated load-carrying capacity with increasing moisture content was confirmed experimentally. A slight increase in the evaluated load-carrying capacity with increasing fastener distance from the loaded end was found.
format Online
Article
Text
id pubmed-7731337
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77313372020-12-12 Effects of Loaded End Distance and Moisture Content on the Behavior of Bolted Connections in Squared and Round Timber Subjected to Tension Parallel to the Grain Lokaj, Antonin Dobes, Pavel Sucharda, Oldrich Materials (Basel) Article This article presents the results of static tests on bolted connections in squared and round timber with inserted steel plates. The experiment evaluates structural timber connections with different distances between the fastener and the loaded end at different moisture contents. Specimens were loaded by tension parallel to the grain and load–deformation diagrams were recorded. Fifty-six specimens with three different distances between the fastener and the loaded end, at different moisture contents, were tested. The results were statistically evaluated using regression analysis, complemented with load–deformation curves, and compared with calculations according to the valid standard for design of timber structures. A decrease in the evaluated load-carrying capacity with increasing moisture content was confirmed experimentally. A slight increase in the evaluated load-carrying capacity with increasing fastener distance from the loaded end was found. MDPI 2020-12-03 /pmc/articles/PMC7731337/ /pubmed/33287370 http://dx.doi.org/10.3390/ma13235525 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lokaj, Antonin
Dobes, Pavel
Sucharda, Oldrich
Effects of Loaded End Distance and Moisture Content on the Behavior of Bolted Connections in Squared and Round Timber Subjected to Tension Parallel to the Grain
title Effects of Loaded End Distance and Moisture Content on the Behavior of Bolted Connections in Squared and Round Timber Subjected to Tension Parallel to the Grain
title_full Effects of Loaded End Distance and Moisture Content on the Behavior of Bolted Connections in Squared and Round Timber Subjected to Tension Parallel to the Grain
title_fullStr Effects of Loaded End Distance and Moisture Content on the Behavior of Bolted Connections in Squared and Round Timber Subjected to Tension Parallel to the Grain
title_full_unstemmed Effects of Loaded End Distance and Moisture Content on the Behavior of Bolted Connections in Squared and Round Timber Subjected to Tension Parallel to the Grain
title_short Effects of Loaded End Distance and Moisture Content on the Behavior of Bolted Connections in Squared and Round Timber Subjected to Tension Parallel to the Grain
title_sort effects of loaded end distance and moisture content on the behavior of bolted connections in squared and round timber subjected to tension parallel to the grain
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7731337/
https://www.ncbi.nlm.nih.gov/pubmed/33287370
http://dx.doi.org/10.3390/ma13235525
work_keys_str_mv AT lokajantonin effectsofloadedenddistanceandmoisturecontentonthebehaviorofboltedconnectionsinsquaredandroundtimbersubjectedtotensionparalleltothegrain
AT dobespavel effectsofloadedenddistanceandmoisturecontentonthebehaviorofboltedconnectionsinsquaredandroundtimbersubjectedtotensionparalleltothegrain
AT suchardaoldrich effectsofloadedenddistanceandmoisturecontentonthebehaviorofboltedconnectionsinsquaredandroundtimbersubjectedtotensionparalleltothegrain