Cargando…

Lower Abnormal Fecal Immunochemical Test Cut-Off Values Improve Detection of Colorectal Cancer in System-Level Screens

BACKGROUND & AIMS: Noninvasive tests used in colorectal cancer screening, such as the fecal immunochemical test (FIT), are more acceptable but detect neoplasias with lower levels of sensitivity than colonoscopy. We investigated whether lowering the cut-off concentration of hemoglobin for designa...

Descripción completa

Detalles Bibliográficos
Autores principales: Berry, Emily, Miller, Stacie, Koch, Mark, Balasubramanian, Bijal, Argenbright, Keith, Gupta, Samir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7731666/
https://www.ncbi.nlm.nih.gov/pubmed/31085338
http://dx.doi.org/10.1016/j.cgh.2019.04.077
_version_ 1783621944358207488
author Berry, Emily
Miller, Stacie
Koch, Mark
Balasubramanian, Bijal
Argenbright, Keith
Gupta, Samir
author_facet Berry, Emily
Miller, Stacie
Koch, Mark
Balasubramanian, Bijal
Argenbright, Keith
Gupta, Samir
author_sort Berry, Emily
collection PubMed
description BACKGROUND & AIMS: Noninvasive tests used in colorectal cancer screening, such as the fecal immunochemical test (FIT), are more acceptable but detect neoplasias with lower levels of sensitivity than colonoscopy. We investigated whether lowering the cut-off concentration of hemoglobin for designation as an abnormal FIT result increased the detection of advanced neoplasia in a mailed outreach program. METHODS: We performed a prospective study of 17,017 uninsured patients, age 50 to 64 years, who were not current with screening and enrolled in a safety-net system in Texas. We reduced the cut-off value for an abnormal FIT result from 20 or more to 10 or more μg hemoglobin/g feces a priori. All patients with abnormal FIT results were offered no-cost diagnostic colonoscopy. We compared proportions of patients with abnormal FIT results and neoplasia yield for standard vs lower cut-off values, as well as absolute hemoglobin concentration distribution among 5838 persons who completed the FIT. Our primary aim was to determine the effects of implementing a lower hemoglobin concentration cut-off value on colonoscopy demand and yield, specifically colorectal cancer (CRC) and advanced neoplasia detection, compared with the standard, higher, hemoglobin concentration cut-off value. RESULTS: The proportions of patients with abnormal FIT results were 12.3% at the 10 or more μg hemoglobin/g feces and 6.6% at the standard 20 or more μg hemoglobin/g feces cut-off value (P = .0013). Detection rates for the lower vs the standard threshold were 10.2% vs 12.7% for advanced neoplasia (P = .12) and 0.9% vs 1.2% for CRC (P = .718). The positive predictive values were 18.9% for the lower threshold vs 24.4% for the standard threshold for advanced neoplasia (P = .053), and 1.7% vs 2.4% for CRC (P = .659). The number needed to screen to detect 1 case with advanced neoplasia was 45 at the lower threshold compared with 58 at the standard threshold; the number needed to scope to detect 1 case with advanced neoplasia increased from 4 to 5. Most patients with CRC (72.7%) or advanced adenoma (67.3%) had hemoglobin concentrations of 20 or more μg/g feces. In the group with 10 to 19 μg hemoglobin/g feces, there were 3 patients with CRC (3 of 11; 27.3%) and 36 with advanced adenoma (36 of 110; 32.7%) who would not have been detected at the standard positive threshold (advanced neoplasia Pcomparison < .001). The proportion of patients found to have no neoplasia after an abnormal FIT result (false positives) was not significantly higher with the lower cut-off value (44.4%) than the standard cut-off value (39.1%) (P = .1103). CONCLUSIONS: In a prospective study of 17,017 uninsured patients, we found that reducing the abnormal FIT result cut-off value (to ≥10 μg hemoglobin/g feces) might increase detection of advanced neoplasia, but doubled the proportion of patients requiring a diagnostic colonoscopy. If colonoscopy capacity permits, health systems that use quantitative FITs should consider lowering the abnormal cut-off value to optimize CRC detection and prevention. (ClinicalTrials.gov no: NCT01946282.)
format Online
Article
Text
id pubmed-7731666
institution National Center for Biotechnology Information
language English
publishDate 2019
record_format MEDLINE/PubMed
spelling pubmed-77316662021-03-01 Lower Abnormal Fecal Immunochemical Test Cut-Off Values Improve Detection of Colorectal Cancer in System-Level Screens Berry, Emily Miller, Stacie Koch, Mark Balasubramanian, Bijal Argenbright, Keith Gupta, Samir Clin Gastroenterol Hepatol Article BACKGROUND & AIMS: Noninvasive tests used in colorectal cancer screening, such as the fecal immunochemical test (FIT), are more acceptable but detect neoplasias with lower levels of sensitivity than colonoscopy. We investigated whether lowering the cut-off concentration of hemoglobin for designation as an abnormal FIT result increased the detection of advanced neoplasia in a mailed outreach program. METHODS: We performed a prospective study of 17,017 uninsured patients, age 50 to 64 years, who were not current with screening and enrolled in a safety-net system in Texas. We reduced the cut-off value for an abnormal FIT result from 20 or more to 10 or more μg hemoglobin/g feces a priori. All patients with abnormal FIT results were offered no-cost diagnostic colonoscopy. We compared proportions of patients with abnormal FIT results and neoplasia yield for standard vs lower cut-off values, as well as absolute hemoglobin concentration distribution among 5838 persons who completed the FIT. Our primary aim was to determine the effects of implementing a lower hemoglobin concentration cut-off value on colonoscopy demand and yield, specifically colorectal cancer (CRC) and advanced neoplasia detection, compared with the standard, higher, hemoglobin concentration cut-off value. RESULTS: The proportions of patients with abnormal FIT results were 12.3% at the 10 or more μg hemoglobin/g feces and 6.6% at the standard 20 or more μg hemoglobin/g feces cut-off value (P = .0013). Detection rates for the lower vs the standard threshold were 10.2% vs 12.7% for advanced neoplasia (P = .12) and 0.9% vs 1.2% for CRC (P = .718). The positive predictive values were 18.9% for the lower threshold vs 24.4% for the standard threshold for advanced neoplasia (P = .053), and 1.7% vs 2.4% for CRC (P = .659). The number needed to screen to detect 1 case with advanced neoplasia was 45 at the lower threshold compared with 58 at the standard threshold; the number needed to scope to detect 1 case with advanced neoplasia increased from 4 to 5. Most patients with CRC (72.7%) or advanced adenoma (67.3%) had hemoglobin concentrations of 20 or more μg/g feces. In the group with 10 to 19 μg hemoglobin/g feces, there were 3 patients with CRC (3 of 11; 27.3%) and 36 with advanced adenoma (36 of 110; 32.7%) who would not have been detected at the standard positive threshold (advanced neoplasia Pcomparison < .001). The proportion of patients found to have no neoplasia after an abnormal FIT result (false positives) was not significantly higher with the lower cut-off value (44.4%) than the standard cut-off value (39.1%) (P = .1103). CONCLUSIONS: In a prospective study of 17,017 uninsured patients, we found that reducing the abnormal FIT result cut-off value (to ≥10 μg hemoglobin/g feces) might increase detection of advanced neoplasia, but doubled the proportion of patients requiring a diagnostic colonoscopy. If colonoscopy capacity permits, health systems that use quantitative FITs should consider lowering the abnormal cut-off value to optimize CRC detection and prevention. (ClinicalTrials.gov no: NCT01946282.) 2019-05-11 2020-03 /pmc/articles/PMC7731666/ /pubmed/31085338 http://dx.doi.org/10.1016/j.cgh.2019.04.077 Text en This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Berry, Emily
Miller, Stacie
Koch, Mark
Balasubramanian, Bijal
Argenbright, Keith
Gupta, Samir
Lower Abnormal Fecal Immunochemical Test Cut-Off Values Improve Detection of Colorectal Cancer in System-Level Screens
title Lower Abnormal Fecal Immunochemical Test Cut-Off Values Improve Detection of Colorectal Cancer in System-Level Screens
title_full Lower Abnormal Fecal Immunochemical Test Cut-Off Values Improve Detection of Colorectal Cancer in System-Level Screens
title_fullStr Lower Abnormal Fecal Immunochemical Test Cut-Off Values Improve Detection of Colorectal Cancer in System-Level Screens
title_full_unstemmed Lower Abnormal Fecal Immunochemical Test Cut-Off Values Improve Detection of Colorectal Cancer in System-Level Screens
title_short Lower Abnormal Fecal Immunochemical Test Cut-Off Values Improve Detection of Colorectal Cancer in System-Level Screens
title_sort lower abnormal fecal immunochemical test cut-off values improve detection of colorectal cancer in system-level screens
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7731666/
https://www.ncbi.nlm.nih.gov/pubmed/31085338
http://dx.doi.org/10.1016/j.cgh.2019.04.077
work_keys_str_mv AT berryemily lowerabnormalfecalimmunochemicaltestcutoffvaluesimprovedetectionofcolorectalcancerinsystemlevelscreens
AT millerstacie lowerabnormalfecalimmunochemicaltestcutoffvaluesimprovedetectionofcolorectalcancerinsystemlevelscreens
AT kochmark lowerabnormalfecalimmunochemicaltestcutoffvaluesimprovedetectionofcolorectalcancerinsystemlevelscreens
AT balasubramanianbijal lowerabnormalfecalimmunochemicaltestcutoffvaluesimprovedetectionofcolorectalcancerinsystemlevelscreens
AT argenbrightkeith lowerabnormalfecalimmunochemicaltestcutoffvaluesimprovedetectionofcolorectalcancerinsystemlevelscreens
AT guptasamir lowerabnormalfecalimmunochemicaltestcutoffvaluesimprovedetectionofcolorectalcancerinsystemlevelscreens