Cargando…

A reverse transcription loop-mediated isothermal amplification for broad coverage detection of Asian and African Zika virus lineages

BACKGROUND: Early detection of Zika virus (ZIKV) infection during the viremia and viruria facilitates proper patient management and mosquito control measurement to prevent disease spread. Therefore, a cost-effective nucleic acid detection method for the diagnosis of ZIKV infection, especially in res...

Descripción completa

Detalles Bibliográficos
Autores principales: Teoh, Boon-Teong, Chin, Kim-Ling, Samsudin, Nur-Izyan, Loong, Shih-Keng, Sam, Sing-Sin, Tan, Kim-Kee, Khor, Chee-Sieng, Abd-Jamil, Juraina, Zainal, Nurhafiza, Wilder-Smith, Annelies, Zandi, Keivan, AbuBakar, Sazaly
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7731766/
https://www.ncbi.nlm.nih.gov/pubmed/33308203
http://dx.doi.org/10.1186/s12879-020-05585-4
Descripción
Sumario:BACKGROUND: Early detection of Zika virus (ZIKV) infection during the viremia and viruria facilitates proper patient management and mosquito control measurement to prevent disease spread. Therefore, a cost-effective nucleic acid detection method for the diagnosis of ZIKV infection, especially in resource-deficient settings, is highly required. METHODS: In the present study, a single-tube reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of both the Asian and African-lineage ZIKV. The detection limit, strain coverage and cross-reactivity of the ZIKV RT-LAMP assay was evaluated. The sensitivity and specificity of the RT-LAMP were also evaluated using a total of 24 simulated clinical samples. The ZIKV quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assay was used as the reference assay. RESULTS: The detection limit of the RT-LAMP assay was 3.73 ZIKV RNA copies (probit analysis, P ≤ 0.05). The RT-LAMP assay detected the ZIKV genomes of both the Asian and African lineages without cross-reacting with other arthropod-borne viruses. The sensitivity and specificity of the RT-LAMP assay were 90% (95% CI = 59.6–98.2) and 100% (95% CI = 78.5–100.0), respectively. The RT-LAMP assay detected ZIKV genome in 9 of 24 (37.5%) of the simulated clinical samples compared to 10 of 24 (41.7%) by qRT-PCR assay with a high level of concordance (κ = 0.913, P < 0.001). CONCLUSION: The RT-LAMP assay is applicable for the broad coverage detection of both the Asian and African ZIKV strains in resource-deficient settings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12879-020-05585-4.