Cargando…

Evaluation of Pulmonary Function Tests Among Pregnant Women of Different Trimesters in Debre Berhan Referral Hospital, Shoa, Ethiopia

INTRODUCTION: Pregnancy is characterized by a sequence of dynamic physiological changes that impact multiple organ system functions and is associated with various changes in pulmonary anatomy and physiology. Precise knowledge of the pulmonary function test parameters helps to understand and manage t...

Descripción completa

Detalles Bibliográficos
Autores principales: Amare, Yosef Eshetie, Haile, Diresibachew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7732161/
https://www.ncbi.nlm.nih.gov/pubmed/33324115
http://dx.doi.org/10.2147/IJWH.S275742
_version_ 1783622033757700096
author Amare, Yosef Eshetie
Haile, Diresibachew
author_facet Amare, Yosef Eshetie
Haile, Diresibachew
author_sort Amare, Yosef Eshetie
collection PubMed
description INTRODUCTION: Pregnancy is characterized by a sequence of dynamic physiological changes that impact multiple organ system functions and is associated with various changes in pulmonary anatomy and physiology. Precise knowledge of the pulmonary function test parameters helps to understand and manage the course and outcome of pregnancy leading to safe delivery. It also helps to avoid misdiagnosis and unnecessary interventions. The aim of this study was to evaluate the effect of normal pregnancy on pulmonary function tests among pregnant women in Debre Berhan Referral Hospital, Ethiopia. METHODS: A total of 176 study participants (first, second, and third trimester; and control) were involved under a comparative cross-sectional study design and convenience sampling technique. Anthropometric data, oxygen saturation of arterial blood, and pulmonary function tests were measured. Data were tabulated and statistically analyzed using SPSS version 20.0 statistical software. Means of all parameters were compared using one-way ANOVA followed by Tukey’s post hoc multiple comparison test. Statistical significance was preset at a p-value of less than 0.05. RESULTS: Mean of FVC for the controls, first, second, and third trimesters was 2.59 ± 0.26, 2.13 ± 0.15, 1.93 ± 0.27, and 1.90 ± 0.11 liters, respectively. Except for FEV(1%,) the mean values of FVC, FEV(1), PEFR, and FEF (25–75%) in the pregnant group (all the three trimesters) were significantly decreased from the controls (P<0.05). Strong negative correlation was seen between SaO(2) and RR (r= −0.865; P <0.01). As the pregnancy progressed from first to the third trimester, dynamic pulmonary function tests (FVC, FEV(1), FEF(25-75%), and PEFR) were dropped and the respiratory rate increased. CONCLUSION: The results had shown the tendency of obstructive pattern while pregnancy becoming advanced. We have observed also a remarkable decline of SaO(2) in pregnant women that might be counterbalanced by raised respiratory rate.
format Online
Article
Text
id pubmed-7732161
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-77321612020-12-14 Evaluation of Pulmonary Function Tests Among Pregnant Women of Different Trimesters in Debre Berhan Referral Hospital, Shoa, Ethiopia Amare, Yosef Eshetie Haile, Diresibachew Int J Womens Health Original Research INTRODUCTION: Pregnancy is characterized by a sequence of dynamic physiological changes that impact multiple organ system functions and is associated with various changes in pulmonary anatomy and physiology. Precise knowledge of the pulmonary function test parameters helps to understand and manage the course and outcome of pregnancy leading to safe delivery. It also helps to avoid misdiagnosis and unnecessary interventions. The aim of this study was to evaluate the effect of normal pregnancy on pulmonary function tests among pregnant women in Debre Berhan Referral Hospital, Ethiopia. METHODS: A total of 176 study participants (first, second, and third trimester; and control) were involved under a comparative cross-sectional study design and convenience sampling technique. Anthropometric data, oxygen saturation of arterial blood, and pulmonary function tests were measured. Data were tabulated and statistically analyzed using SPSS version 20.0 statistical software. Means of all parameters were compared using one-way ANOVA followed by Tukey’s post hoc multiple comparison test. Statistical significance was preset at a p-value of less than 0.05. RESULTS: Mean of FVC for the controls, first, second, and third trimesters was 2.59 ± 0.26, 2.13 ± 0.15, 1.93 ± 0.27, and 1.90 ± 0.11 liters, respectively. Except for FEV(1%,) the mean values of FVC, FEV(1), PEFR, and FEF (25–75%) in the pregnant group (all the three trimesters) were significantly decreased from the controls (P<0.05). Strong negative correlation was seen between SaO(2) and RR (r= −0.865; P <0.01). As the pregnancy progressed from first to the third trimester, dynamic pulmonary function tests (FVC, FEV(1), FEF(25-75%), and PEFR) were dropped and the respiratory rate increased. CONCLUSION: The results had shown the tendency of obstructive pattern while pregnancy becoming advanced. We have observed also a remarkable decline of SaO(2) in pregnant women that might be counterbalanced by raised respiratory rate. Dove 2020-12-07 /pmc/articles/PMC7732161/ /pubmed/33324115 http://dx.doi.org/10.2147/IJWH.S275742 Text en © 2020 Amare and Haile. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Amare, Yosef Eshetie
Haile, Diresibachew
Evaluation of Pulmonary Function Tests Among Pregnant Women of Different Trimesters in Debre Berhan Referral Hospital, Shoa, Ethiopia
title Evaluation of Pulmonary Function Tests Among Pregnant Women of Different Trimesters in Debre Berhan Referral Hospital, Shoa, Ethiopia
title_full Evaluation of Pulmonary Function Tests Among Pregnant Women of Different Trimesters in Debre Berhan Referral Hospital, Shoa, Ethiopia
title_fullStr Evaluation of Pulmonary Function Tests Among Pregnant Women of Different Trimesters in Debre Berhan Referral Hospital, Shoa, Ethiopia
title_full_unstemmed Evaluation of Pulmonary Function Tests Among Pregnant Women of Different Trimesters in Debre Berhan Referral Hospital, Shoa, Ethiopia
title_short Evaluation of Pulmonary Function Tests Among Pregnant Women of Different Trimesters in Debre Berhan Referral Hospital, Shoa, Ethiopia
title_sort evaluation of pulmonary function tests among pregnant women of different trimesters in debre berhan referral hospital, shoa, ethiopia
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7732161/
https://www.ncbi.nlm.nih.gov/pubmed/33324115
http://dx.doi.org/10.2147/IJWH.S275742
work_keys_str_mv AT amareyosefeshetie evaluationofpulmonaryfunctiontestsamongpregnantwomenofdifferenttrimestersindebreberhanreferralhospitalshoaethiopia
AT hailediresibachew evaluationofpulmonaryfunctiontestsamongpregnantwomenofdifferenttrimestersindebreberhanreferralhospitalshoaethiopia