Cargando…

Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment

The mDurance® system is an innovative digital tool that combines wearable surface electromyography (sEMG), mobile computing and cloud analysis to streamline and automatize the assessment of muscle activity. The tool is particularly devised to support clinicians and sport professionals in their daily...

Descripción completa

Detalles Bibliográficos
Autores principales: Molina-Molina, Alejandro, Ruiz-Malagón, Emilio J., Carrillo-Pérez, Francisco, Roche-Seruendo, Luis E., Damas, Miguel, Banos, Oresti, García-Pinillos, Felipe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7732544/
https://www.ncbi.nlm.nih.gov/pubmed/33329060
http://dx.doi.org/10.3389/fphys.2020.606287
_version_ 1783622119082426368
author Molina-Molina, Alejandro
Ruiz-Malagón, Emilio J.
Carrillo-Pérez, Francisco
Roche-Seruendo, Luis E.
Damas, Miguel
Banos, Oresti
García-Pinillos, Felipe
author_facet Molina-Molina, Alejandro
Ruiz-Malagón, Emilio J.
Carrillo-Pérez, Francisco
Roche-Seruendo, Luis E.
Damas, Miguel
Banos, Oresti
García-Pinillos, Felipe
author_sort Molina-Molina, Alejandro
collection PubMed
description The mDurance® system is an innovative digital tool that combines wearable surface electromyography (sEMG), mobile computing and cloud analysis to streamline and automatize the assessment of muscle activity. The tool is particularly devised to support clinicians and sport professionals in their daily routines, as an assessment tool in the prevention, monitoring rehabilitation and training field. This study aimed at determining the validity of the mDurance system for measuring muscle activity by comparing sEMG output with a reference sEMG system, the Delsys® system. Fifteen participants were tested during isokinetic knee extensions at three different speeds (60, 180, and 300 deg/s), for two muscles (rectus femoris [RF] and vastus lateralis [VL]) and two different electrodes locations (proximal and distal placement). The maximum voluntary isometric contraction was carried out for the normalization of the signal, followed by dynamic isokinetic knee extensions for each speed. The sEMG output for both systems was obtained from the raw sEMG signal following mDurance's processing and filtering. Mean, median, first quartile, third quartile and 90th percentile was calculated from the sEMG amplitude signals for each system. The results show an almost perfect ICC relationship for the VL (ICC > 0.81) and substantial to almost perfect for the RF (ICC > 0.762) for all variables and speeds. The Bland-Altman plots revealed heteroscedasticity of error for mean, quartile 3 and 90th percentile (60 and 300 deg/s) for RF and at mean and 90th percentile for VL (300 deg/s). In conclusion, the results indicate that the mDurance® sEMG system is a valid tool to measure muscle activity during dynamic contractions over a range of speeds. This innovative system provides more time for clinicians (e.g., interpretation patients' pathologies) and sport trainers (e.g., advising athletes), thanks to automatic processing and filtering of the raw sEMG signal and generation of muscle activity reports in real-time.
format Online
Article
Text
id pubmed-7732544
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-77325442020-12-15 Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment Molina-Molina, Alejandro Ruiz-Malagón, Emilio J. Carrillo-Pérez, Francisco Roche-Seruendo, Luis E. Damas, Miguel Banos, Oresti García-Pinillos, Felipe Front Physiol Physiology The mDurance® system is an innovative digital tool that combines wearable surface electromyography (sEMG), mobile computing and cloud analysis to streamline and automatize the assessment of muscle activity. The tool is particularly devised to support clinicians and sport professionals in their daily routines, as an assessment tool in the prevention, monitoring rehabilitation and training field. This study aimed at determining the validity of the mDurance system for measuring muscle activity by comparing sEMG output with a reference sEMG system, the Delsys® system. Fifteen participants were tested during isokinetic knee extensions at three different speeds (60, 180, and 300 deg/s), for two muscles (rectus femoris [RF] and vastus lateralis [VL]) and two different electrodes locations (proximal and distal placement). The maximum voluntary isometric contraction was carried out for the normalization of the signal, followed by dynamic isokinetic knee extensions for each speed. The sEMG output for both systems was obtained from the raw sEMG signal following mDurance's processing and filtering. Mean, median, first quartile, third quartile and 90th percentile was calculated from the sEMG amplitude signals for each system. The results show an almost perfect ICC relationship for the VL (ICC > 0.81) and substantial to almost perfect for the RF (ICC > 0.762) for all variables and speeds. The Bland-Altman plots revealed heteroscedasticity of error for mean, quartile 3 and 90th percentile (60 and 300 deg/s) for RF and at mean and 90th percentile for VL (300 deg/s). In conclusion, the results indicate that the mDurance® sEMG system is a valid tool to measure muscle activity during dynamic contractions over a range of speeds. This innovative system provides more time for clinicians (e.g., interpretation patients' pathologies) and sport trainers (e.g., advising athletes), thanks to automatic processing and filtering of the raw sEMG signal and generation of muscle activity reports in real-time. Frontiers Media S.A. 2020-11-27 /pmc/articles/PMC7732544/ /pubmed/33329060 http://dx.doi.org/10.3389/fphys.2020.606287 Text en Copyright © 2020 Molina-Molina, Ruiz-Malagón, Carrillo-Pérez, Roche-Seruendo, Damas, Banos and García-Pinillos. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Molina-Molina, Alejandro
Ruiz-Malagón, Emilio J.
Carrillo-Pérez, Francisco
Roche-Seruendo, Luis E.
Damas, Miguel
Banos, Oresti
García-Pinillos, Felipe
Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment
title Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment
title_full Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment
title_fullStr Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment
title_full_unstemmed Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment
title_short Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment
title_sort validation of mdurance, a wearable surface electromyography system for muscle activity assessment
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7732544/
https://www.ncbi.nlm.nih.gov/pubmed/33329060
http://dx.doi.org/10.3389/fphys.2020.606287
work_keys_str_mv AT molinamolinaalejandro validationofmduranceawearablesurfaceelectromyographysystemformuscleactivityassessment
AT ruizmalagonemilioj validationofmduranceawearablesurfaceelectromyographysystemformuscleactivityassessment
AT carrilloperezfrancisco validationofmduranceawearablesurfaceelectromyographysystemformuscleactivityassessment
AT rocheseruendoluise validationofmduranceawearablesurfaceelectromyographysystemformuscleactivityassessment
AT damasmiguel validationofmduranceawearablesurfaceelectromyographysystemformuscleactivityassessment
AT banosoresti validationofmduranceawearablesurfaceelectromyographysystemformuscleactivityassessment
AT garciapinillosfelipe validationofmduranceawearablesurfaceelectromyographysystemformuscleactivityassessment