Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design

BACKGROUND: Three-dimensional scans are increasingly used to quantify biological topographical changes and clinical health outcomes. Traditionally, the use of 3D scans has been limited to specialized centers owing to the high cost of the scanning equipment and the necessity for complex analysis soft...

Descripción completa

Detalles Bibliográficos
Autores principales: O'Toole, Saoirse, Bartlett, David, Keeling, Andrew, McBride, John, Bernabe, Eduardo, Crins, Luuk, Loomans, Bas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7732705/
https://www.ncbi.nlm.nih.gov/pubmed/33245280
http://dx.doi.org/10.2196/17150
_version_ 1783622153273344000
author O'Toole, Saoirse
Bartlett, David
Keeling, Andrew
McBride, John
Bernabe, Eduardo
Crins, Luuk
Loomans, Bas
author_facet O'Toole, Saoirse
Bartlett, David
Keeling, Andrew
McBride, John
Bernabe, Eduardo
Crins, Luuk
Loomans, Bas
author_sort O'Toole, Saoirse
collection PubMed
description BACKGROUND: Three-dimensional scans are increasingly used to quantify biological topographical changes and clinical health outcomes. Traditionally, the use of 3D scans has been limited to specialized centers owing to the high cost of the scanning equipment and the necessity for complex analysis software. Technological advances have made cheaper, more accessible methods of data capture and analysis available in the field of dentistry, potentially facilitating a primary care system to quantify disease progression. However, this system has yet to be compared with previous high-precision methods in university hospital settings. OBJECTIVE: The aim of this study was to compare a dental primary care method of data capture (intraoral scanner) with a precision hospital-based method (laser profilometer) in addition to comparing open source and commercial software available for data analysis. METHODS: Longitudinal dental wear data from 30 patients were analyzed using a two-factor factorial experimental design. Bimaxillary intraoral digital scans (TrueDefinition, 3M, UK) and conventional silicone impressions, poured in type-4 dental stone, were made at both baseline and follow-up appointments (mean 36 months, SD 10.9). Stone models were scanned using precision laser profilometry (Taicaan, Southampton, UK). Three-dimensional changes in both forms of digital scans of the first molars (n=76) were quantitatively analyzed using the engineering software Geomagic Control (3D Systems, Germany) and freeware WearCompare (Leeds Digital Dentistry, UK). Volume change (mm(3)) was the primary measurement outcome. The maximum point loss (μm) and the average profile loss (μm) were also recorded. Data were paired and skewed, and were therefore compared using Wilcoxon signed-rank tests with Bonferroni correction. RESULTS: The median (IQR) volume change for Geomagic using profilometry and using the intraoral scan was –0.37 mm(3) (–3.75-2.30) and +0.51 mm(3) (–2.17-4.26), respectively (P<.001). Using WearCompare, the median (IQR) volume change for profilometry and intraoral scanning was –1.21 mm(3) (–3.48-0.56) and –0.39 mm(3) (–3.96-2.76), respectively (P=.04). WearCompare detected significantly greater volume loss than Geomagic regardless of scanner type. No differences were observed between groups with respect to the maximum point loss or average profile loss. CONCLUSIONS: As expected, the method of data capture, software used, and measurement metric all significantly influenced the measurement outcome. However, when appropriate analysis was used, the primary care system was able to quantify the degree of change and can be recommended depending on the accuracy needed to diagnose a condition. Lower-resolution scanners may underestimate complex changes when measuring at the micron level.
format Online
Article
Text
id pubmed-7732705
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-77327052020-12-22 Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design O'Toole, Saoirse Bartlett, David Keeling, Andrew McBride, John Bernabe, Eduardo Crins, Luuk Loomans, Bas J Med Internet Res Original Paper BACKGROUND: Three-dimensional scans are increasingly used to quantify biological topographical changes and clinical health outcomes. Traditionally, the use of 3D scans has been limited to specialized centers owing to the high cost of the scanning equipment and the necessity for complex analysis software. Technological advances have made cheaper, more accessible methods of data capture and analysis available in the field of dentistry, potentially facilitating a primary care system to quantify disease progression. However, this system has yet to be compared with previous high-precision methods in university hospital settings. OBJECTIVE: The aim of this study was to compare a dental primary care method of data capture (intraoral scanner) with a precision hospital-based method (laser profilometer) in addition to comparing open source and commercial software available for data analysis. METHODS: Longitudinal dental wear data from 30 patients were analyzed using a two-factor factorial experimental design. Bimaxillary intraoral digital scans (TrueDefinition, 3M, UK) and conventional silicone impressions, poured in type-4 dental stone, were made at both baseline and follow-up appointments (mean 36 months, SD 10.9). Stone models were scanned using precision laser profilometry (Taicaan, Southampton, UK). Three-dimensional changes in both forms of digital scans of the first molars (n=76) were quantitatively analyzed using the engineering software Geomagic Control (3D Systems, Germany) and freeware WearCompare (Leeds Digital Dentistry, UK). Volume change (mm(3)) was the primary measurement outcome. The maximum point loss (μm) and the average profile loss (μm) were also recorded. Data were paired and skewed, and were therefore compared using Wilcoxon signed-rank tests with Bonferroni correction. RESULTS: The median (IQR) volume change for Geomagic using profilometry and using the intraoral scan was –0.37 mm(3) (–3.75-2.30) and +0.51 mm(3) (–2.17-4.26), respectively (P<.001). Using WearCompare, the median (IQR) volume change for profilometry and intraoral scanning was –1.21 mm(3) (–3.48-0.56) and –0.39 mm(3) (–3.96-2.76), respectively (P=.04). WearCompare detected significantly greater volume loss than Geomagic regardless of scanner type. No differences were observed between groups with respect to the maximum point loss or average profile loss. CONCLUSIONS: As expected, the method of data capture, software used, and measurement metric all significantly influenced the measurement outcome. However, when appropriate analysis was used, the primary care system was able to quantify the degree of change and can be recommended depending on the accuracy needed to diagnose a condition. Lower-resolution scanners may underestimate complex changes when measuring at the micron level. JMIR Publications 2020-11-27 /pmc/articles/PMC7732705/ /pubmed/33245280 http://dx.doi.org/10.2196/17150 Text en ©Saoirse O'Toole, David Bartlett, Andrew Keeling, John McBride, Eduardo Bernabe, Luuk Crins, Bas Loomans. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 27.11.2020. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on http://www.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
O'Toole, Saoirse
Bartlett, David
Keeling, Andrew
McBride, John
Bernabe, Eduardo
Crins, Luuk
Loomans, Bas
Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design
title Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design
title_full Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design
title_fullStr Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design
title_full_unstemmed Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design
title_short Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design
title_sort influence of scanner precision and analysis software in quantifying three-dimensional intraoral changes: two-factor factorial experimental design
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7732705/
https://www.ncbi.nlm.nih.gov/pubmed/33245280
http://dx.doi.org/10.2196/17150
work_keys_str_mv AT otoolesaoirse influenceofscannerprecisionandanalysissoftwareinquantifyingthreedimensionalintraoralchangestwofactorfactorialexperimentaldesign
AT bartlettdavid influenceofscannerprecisionandanalysissoftwareinquantifyingthreedimensionalintraoralchangestwofactorfactorialexperimentaldesign
AT keelingandrew influenceofscannerprecisionandanalysissoftwareinquantifyingthreedimensionalintraoralchangestwofactorfactorialexperimentaldesign
AT mcbridejohn influenceofscannerprecisionandanalysissoftwareinquantifyingthreedimensionalintraoralchangestwofactorfactorialexperimentaldesign
AT bernabeeduardo influenceofscannerprecisionandanalysissoftwareinquantifyingthreedimensionalintraoralchangestwofactorfactorialexperimentaldesign
AT crinsluuk influenceofscannerprecisionandanalysissoftwareinquantifyingthreedimensionalintraoralchangestwofactorfactorialexperimentaldesign
AT loomansbas influenceofscannerprecisionandanalysissoftwareinquantifyingthreedimensionalintraoralchangestwofactorfactorialexperimentaldesign