Cargando…

FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations

BACKGROUND: Cochlear implant (CI) recipients with a cochleovestibular malformation (CVM) are at a higher risk of experiencing an intra-operative cerebrospinal fluid (CSF) gusher and, therefore are at greater risk of developing postoperative meningitis than are CI recipients with normal cochlear anat...

Descripción completa

Detalles Bibliográficos
Autores principales: Halawani, Roa, Alzhrani, Farid, Almuhawas, Fida, Hagr, Abdulrahman Abdullah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: King Faisal Specialist Hospital and Research Centre 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7733640/
https://www.ncbi.nlm.nih.gov/pubmed/33307737
http://dx.doi.org/10.5144/0256-4947.2020.477
_version_ 1783622314490855424
author Halawani, Roa
Alzhrani, Farid
Almuhawas, Fida
Hagr, Abdulrahman Abdullah
author_facet Halawani, Roa
Alzhrani, Farid
Almuhawas, Fida
Hagr, Abdulrahman Abdullah
author_sort Halawani, Roa
collection PubMed
description BACKGROUND: Cochlear implant (CI) recipients with a cochleovestibular malformation (CVM) are at a higher risk of experiencing an intra-operative cerebrospinal fluid (CSF) gusher and, therefore are at greater risk of developing postoperative meningitis than are CI recipients with normal cochlear anatomy. To control CSF gushers, the FORM electrode array was developed. OBJECTIVES: To assess the ability of the FORM24 electrode array in managing intraoperative CSF gushers and preventing postoperative CSF leakage in a population of CI recipients. DESIGN: Retrospective. SETTING: Tertiary health care center. PATIENTS AND METHODS: All CIs in which a FORM24 was used between January 2014 and March 2018 were reviewed for demographic and safety results. MAIN OUTCOME MEASURES: Safety results were assessed as the intraoperative or postoperative presence of an episode of CSF leakage or meningitis. SAMPLE SIZE: 177 CI recipients. RESULTS: Thirty-six (20.3%) had a CVM and 141 had normal anatomy (79.7%). Of the 36 participants with a CVM, 20 (55.6%) experienced an intraoperative CSF gusher, all of which were resolved. No cases of postoperative leakage or meningitis were recorded after a mean follow-up time of 36 months. CONCLUSION: The FORM24 array is able to help surgeons stop intraoperative CSF gushers and prevent postoperative CSF leakage and meningitis in CI recipients with a CVM. LIMITATIONS: Further studies are needed. CONFLICT OF INTEREST: None.
format Online
Article
Text
id pubmed-7733640
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher King Faisal Specialist Hospital and Research Centre
record_format MEDLINE/PubMed
spelling pubmed-77336402020-12-21 FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations Halawani, Roa Alzhrani, Farid Almuhawas, Fida Hagr, Abdulrahman Abdullah Ann Saudi Med Original Article BACKGROUND: Cochlear implant (CI) recipients with a cochleovestibular malformation (CVM) are at a higher risk of experiencing an intra-operative cerebrospinal fluid (CSF) gusher and, therefore are at greater risk of developing postoperative meningitis than are CI recipients with normal cochlear anatomy. To control CSF gushers, the FORM electrode array was developed. OBJECTIVES: To assess the ability of the FORM24 electrode array in managing intraoperative CSF gushers and preventing postoperative CSF leakage in a population of CI recipients. DESIGN: Retrospective. SETTING: Tertiary health care center. PATIENTS AND METHODS: All CIs in which a FORM24 was used between January 2014 and March 2018 were reviewed for demographic and safety results. MAIN OUTCOME MEASURES: Safety results were assessed as the intraoperative or postoperative presence of an episode of CSF leakage or meningitis. SAMPLE SIZE: 177 CI recipients. RESULTS: Thirty-six (20.3%) had a CVM and 141 had normal anatomy (79.7%). Of the 36 participants with a CVM, 20 (55.6%) experienced an intraoperative CSF gusher, all of which were resolved. No cases of postoperative leakage or meningitis were recorded after a mean follow-up time of 36 months. CONCLUSION: The FORM24 array is able to help surgeons stop intraoperative CSF gushers and prevent postoperative CSF leakage and meningitis in CI recipients with a CVM. LIMITATIONS: Further studies are needed. CONFLICT OF INTEREST: None. King Faisal Specialist Hospital and Research Centre 2020-11 2020-12-03 /pmc/articles/PMC7733640/ /pubmed/33307737 http://dx.doi.org/10.5144/0256-4947.2020.477 Text en Copyright © 2020, Annals of Saudi Medicine, Saudi Arabia This is an open access article under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND). The details of which can be accessed at http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Original Article
Halawani, Roa
Alzhrani, Farid
Almuhawas, Fida
Hagr, Abdulrahman Abdullah
FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations
title FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations
title_full FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations
title_fullStr FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations
title_full_unstemmed FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations
title_short FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations
title_sort form24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7733640/
https://www.ncbi.nlm.nih.gov/pubmed/33307737
http://dx.doi.org/10.5144/0256-4947.2020.477
work_keys_str_mv AT halawaniroa form24electrodearrayandperioperativecerebrospinalfluidleakageincochlearimplantrecipientswithcochleovestibularmalformations
AT alzhranifarid form24electrodearrayandperioperativecerebrospinalfluidleakageincochlearimplantrecipientswithcochleovestibularmalformations
AT almuhawasfida form24electrodearrayandperioperativecerebrospinalfluidleakageincochlearimplantrecipientswithcochleovestibularmalformations
AT hagrabdulrahmanabdullah form24electrodearrayandperioperativecerebrospinalfluidleakageincochlearimplantrecipientswithcochleovestibularmalformations