Cargando…
Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
BACKGROUND: Hybrid closed-wedge high tibial osteotomy (hybrid CWHTO) is an effective surgical treatment for medial compartment osteoarthritis of the knee. Our study investigated whether the combination of a lateral locking plate and a single medial screw promoted bone union after hybrid CWHTO. METHO...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7734755/ https://www.ncbi.nlm.nih.gov/pubmed/33317642 http://dx.doi.org/10.1186/s43019-020-00085-w |
_version_ | 1783622528697106432 |
---|---|
author | Hiraoka, Nobuyuki Nakagawa, Shuji Otakara, Eigo Inoue, Hiroaki Takahashi, Kenji Arai, Yuji |
author_facet | Hiraoka, Nobuyuki Nakagawa, Shuji Otakara, Eigo Inoue, Hiroaki Takahashi, Kenji Arai, Yuji |
author_sort | Hiraoka, Nobuyuki |
collection | PubMed |
description | BACKGROUND: Hybrid closed-wedge high tibial osteotomy (hybrid CWHTO) is an effective surgical treatment for medial compartment osteoarthritis of the knee. Our study investigated whether the combination of a lateral locking plate and a single medial screw promoted bone union after hybrid CWHTO. METHODS: The study cohort consisted of 30 patients (15 men and 15 women) who underwent hybrid CWHTO for medial compartment osteoarthritis or spontaneous osteonecrosis of the knee. Sixteen knees were fixed with a lateral locking plate (LP group), and 17 were fixed with both a lateral locking plate and a cannulated cancellous screw on the medial side of the tibia (LPS group). The times to bone union, radiolucency, and callus formation at the osteotomy site were evaluated radiographically. RESULTS: The mean postoperative time to radiographic confirmation of bone union was 5.5 ± 2.6 months in the LP group and 3.4 ± 1.5 months in the LPS group. Radiolucency at the osteotomy site and excess callus formation on the posterior side of the tibia were lower in the LPS group than in the LP group. CONCLUSIONS: This modified hybrid CWHTO combining a lateral locking plate and a cannulated cancellous screw on the medial side of the tibia improves the stability of the osteotomy site and shortens the period of bone union. |
format | Online Article Text |
id | pubmed-7734755 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-77347552020-12-21 Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy Hiraoka, Nobuyuki Nakagawa, Shuji Otakara, Eigo Inoue, Hiroaki Takahashi, Kenji Arai, Yuji Knee Surg Relat Res Research Article BACKGROUND: Hybrid closed-wedge high tibial osteotomy (hybrid CWHTO) is an effective surgical treatment for medial compartment osteoarthritis of the knee. Our study investigated whether the combination of a lateral locking plate and a single medial screw promoted bone union after hybrid CWHTO. METHODS: The study cohort consisted of 30 patients (15 men and 15 women) who underwent hybrid CWHTO for medial compartment osteoarthritis or spontaneous osteonecrosis of the knee. Sixteen knees were fixed with a lateral locking plate (LP group), and 17 were fixed with both a lateral locking plate and a cannulated cancellous screw on the medial side of the tibia (LPS group). The times to bone union, radiolucency, and callus formation at the osteotomy site were evaluated radiographically. RESULTS: The mean postoperative time to radiographic confirmation of bone union was 5.5 ± 2.6 months in the LP group and 3.4 ± 1.5 months in the LPS group. Radiolucency at the osteotomy site and excess callus formation on the posterior side of the tibia were lower in the LPS group than in the LP group. CONCLUSIONS: This modified hybrid CWHTO combining a lateral locking plate and a cannulated cancellous screw on the medial side of the tibia improves the stability of the osteotomy site and shortens the period of bone union. BioMed Central 2020-12-14 /pmc/articles/PMC7734755/ /pubmed/33317642 http://dx.doi.org/10.1186/s43019-020-00085-w Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Hiraoka, Nobuyuki Nakagawa, Shuji Otakara, Eigo Inoue, Hiroaki Takahashi, Kenji Arai, Yuji Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy |
title | Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy |
title_full | Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy |
title_fullStr | Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy |
title_full_unstemmed | Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy |
title_short | Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy |
title_sort | radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7734755/ https://www.ncbi.nlm.nih.gov/pubmed/33317642 http://dx.doi.org/10.1186/s43019-020-00085-w |
work_keys_str_mv | AT hiraokanobuyuki radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy AT nakagawashuji radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy AT otakaraeigo radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy AT inouehiroaki radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy AT takahashikenji radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy AT araiyuji radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy |