Cargando…

Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy

BACKGROUND: Hybrid closed-wedge high tibial osteotomy (hybrid CWHTO) is an effective surgical treatment for medial compartment osteoarthritis of the knee. Our study investigated whether the combination of a lateral locking plate and a single medial screw promoted bone union after hybrid CWHTO. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: Hiraoka, Nobuyuki, Nakagawa, Shuji, Otakara, Eigo, Inoue, Hiroaki, Takahashi, Kenji, Arai, Yuji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7734755/
https://www.ncbi.nlm.nih.gov/pubmed/33317642
http://dx.doi.org/10.1186/s43019-020-00085-w
_version_ 1783622528697106432
author Hiraoka, Nobuyuki
Nakagawa, Shuji
Otakara, Eigo
Inoue, Hiroaki
Takahashi, Kenji
Arai, Yuji
author_facet Hiraoka, Nobuyuki
Nakagawa, Shuji
Otakara, Eigo
Inoue, Hiroaki
Takahashi, Kenji
Arai, Yuji
author_sort Hiraoka, Nobuyuki
collection PubMed
description BACKGROUND: Hybrid closed-wedge high tibial osteotomy (hybrid CWHTO) is an effective surgical treatment for medial compartment osteoarthritis of the knee. Our study investigated whether the combination of a lateral locking plate and a single medial screw promoted bone union after hybrid CWHTO. METHODS: The study cohort consisted of 30 patients (15 men and 15 women) who underwent hybrid CWHTO for medial compartment osteoarthritis or spontaneous osteonecrosis of the knee. Sixteen knees were fixed with a lateral locking plate (LP group), and 17 were fixed with both a lateral locking plate and a cannulated cancellous screw on the medial side of the tibia (LPS group). The times to bone union, radiolucency, and callus formation at the osteotomy site were evaluated radiographically. RESULTS: The mean postoperative time to radiographic confirmation of bone union was 5.5 ± 2.6 months in the LP group and 3.4 ± 1.5 months in the LPS group. Radiolucency at the osteotomy site and excess callus formation on the posterior side of the tibia were lower in the LPS group than in the LP group. CONCLUSIONS: This modified hybrid CWHTO combining a lateral locking plate and a cannulated cancellous screw on the medial side of the tibia improves the stability of the osteotomy site and shortens the period of bone union.
format Online
Article
Text
id pubmed-7734755
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-77347552020-12-21 Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy Hiraoka, Nobuyuki Nakagawa, Shuji Otakara, Eigo Inoue, Hiroaki Takahashi, Kenji Arai, Yuji Knee Surg Relat Res Research Article BACKGROUND: Hybrid closed-wedge high tibial osteotomy (hybrid CWHTO) is an effective surgical treatment for medial compartment osteoarthritis of the knee. Our study investigated whether the combination of a lateral locking plate and a single medial screw promoted bone union after hybrid CWHTO. METHODS: The study cohort consisted of 30 patients (15 men and 15 women) who underwent hybrid CWHTO for medial compartment osteoarthritis or spontaneous osteonecrosis of the knee. Sixteen knees were fixed with a lateral locking plate (LP group), and 17 were fixed with both a lateral locking plate and a cannulated cancellous screw on the medial side of the tibia (LPS group). The times to bone union, radiolucency, and callus formation at the osteotomy site were evaluated radiographically. RESULTS: The mean postoperative time to radiographic confirmation of bone union was 5.5 ± 2.6 months in the LP group and 3.4 ± 1.5 months in the LPS group. Radiolucency at the osteotomy site and excess callus formation on the posterior side of the tibia were lower in the LPS group than in the LP group. CONCLUSIONS: This modified hybrid CWHTO combining a lateral locking plate and a cannulated cancellous screw on the medial side of the tibia improves the stability of the osteotomy site and shortens the period of bone union. BioMed Central 2020-12-14 /pmc/articles/PMC7734755/ /pubmed/33317642 http://dx.doi.org/10.1186/s43019-020-00085-w Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Hiraoka, Nobuyuki
Nakagawa, Shuji
Otakara, Eigo
Inoue, Hiroaki
Takahashi, Kenji
Arai, Yuji
Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
title Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
title_full Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
title_fullStr Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
title_full_unstemmed Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
title_short Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
title_sort radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7734755/
https://www.ncbi.nlm.nih.gov/pubmed/33317642
http://dx.doi.org/10.1186/s43019-020-00085-w
work_keys_str_mv AT hiraokanobuyuki radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy
AT nakagawashuji radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy
AT otakaraeigo radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy
AT inouehiroaki radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy
AT takahashikenji radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy
AT araiyuji radiologicresultsofadditionalsinglescrewfixationwithlaterallockingplateafterhybridclosedwedgehightibialosteotomy