Method comparison of HPLC-ninhydrin-photometry and UHPLC-PITC-tandem mass spectrometry for serum amino acid analyses in patients with complex congenital heart disease and controls
INTRODUCTION: Metabolomics studies are not routine when quantifying amino acids (AA) in congenital heart disease (CHD). OBJECTIVES: Comparative analysis of 24 AA in serum by traditional high-performance liquid chromatography (HPLC) based on ion exchange and ninhydrin derivatisation followed by photo...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7736021/ https://www.ncbi.nlm.nih.gov/pubmed/33319318 http://dx.doi.org/10.1007/s11306-020-01741-8 |
Sumario: | INTRODUCTION: Metabolomics studies are not routine when quantifying amino acids (AA) in congenital heart disease (CHD). OBJECTIVES: Comparative analysis of 24 AA in serum by traditional high-performance liquid chromatography (HPLC) based on ion exchange and ninhydrin derivatisation followed by photometry (PM) with ultra-high-performance liquid chromatography and phenylisothiocyanate derivatisation followed by tandem mass spectrometry (TMS); interpretation of findings in CHD patients and controls. METHODS: PM: Sample analysis as above (total run time, ~ 119 min). TMS: Sample analysis by AbsoluteIDQ® p180 kit assay (BIOCRATES Life Sciences AG, Innsbruck, Austria), which employs PITC derivatisation; separation of analytes on a Waters Acquity UHPLC BEH18 C18 reversed-phase column, using water and acetonitrile with 0.1% formic acid as the mobile phases; and quantification on a Triple-Stage Quadrupole tandem mass spectrometer (Thermo Fisher Scientific, Waltham, MA) with electrospray ionisation in the presence of internal standards (total run time, ~ 8 min). Calculation of coefficients of variation (CV) (for precision), intra- and interday accuracies, limits of detection (LOD), limits of quantification (LOQ), and mean concentrations. RESULTS: Both methods yielded acceptable results with regard to precision (CV < 10% PM, < 20% TMS), accuracies (< 10% PM, < 34% TMS), LOD, and LOQ. For both Fontan patients and controls AA concentrations differed significantly between methods, but patterns yielded overall were parallel. CONCLUSION: Serum AA concentrations differ with analytical methods but both methods are suitable for AA pattern recognition. TMS is a time-saving alternative to traditional PM under physiological conditions as well as in patients with CHD. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier NCT03886935, date of registration March 27th, 2019 (retrospectively registered). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11306-020-01741-8. |
---|