Cargando…
Chemical Elements in Electronic Cigarette Solvents and Aerosols Inhibit Mitochondrial Reductases and Induce Oxidative Stress
INTRODUCTION: Chemical elements and their toxicity were evaluated in electronic cigarette (EC) solvents, fluids, and aerosols. AIMS AND METHODS: Element identification and quantification in propylene glycol (PG), glycerin (G), refill fluids before and after use, and aerosols was done using inductive...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7737483/ https://www.ncbi.nlm.nih.gov/pubmed/33320250 http://dx.doi.org/10.1093/ntr/ntaa193 |
_version_ | 1783622950736363520 |
---|---|
author | Williams, Monique Ventura, Jesse Loza, Antonio Wang, Yuhuan Talbot, Prue |
author_facet | Williams, Monique Ventura, Jesse Loza, Antonio Wang, Yuhuan Talbot, Prue |
author_sort | Williams, Monique |
collection | PubMed |
description | INTRODUCTION: Chemical elements and their toxicity were evaluated in electronic cigarette (EC) solvents, fluids, and aerosols. AIMS AND METHODS: Element identification and quantification in propylene glycol (PG), glycerin (G), refill fluids before and after use, and aerosols was done using inductively coupled plasma optical emission spectrometry. Cytotoxicity and oxidative stress were evaluated using in vitro assays. RESULTS: Seven elements were present in PG, G, and popular refill fluids, and they transferred to aerosols made with ECs. Selenium was in all products (0.125–0.292 mg/L), while arsenic, aluminum, and tin were frequently in solvent and refill fluid samples at lower concentrations. Iron, chromium, copper, nickel, zinc, and lead were only detected in fluid after EC use, indicating they came from heated atomizers. Elements transferred most efficiently to aerosols made with second-/third-generation ECs. Of the elements in fluid, selenium and arsenic were the most cytotoxic to human bronchial epithelial cells (BEAS-2B) and pulmonary fibroblasts in the 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide assay. Selenium increased superoxide production in mitochondria and nucleoli and elevated selenoprotein H in nucleoli of BEAS-2B cells at concentrations found in EC aerosols (10 nM or 0.002 mg/L). CONCLUSIONS: Elements in EC aerosols came from both e-fluids and atomizing units. Within second-/third-generation products, transfer became more efficient as power increased. In vitro responses occurred at concentrations of selenium found in some EC aerosols. Human exposure to chemical elements in ECs could be reduced by regulating (decreasing) allowable EC power and by improving the purity of PG and G. IMPLICATIONS: PG, G, refill fluids, and e-fluids contained potentially toxic chemical elements that transferred to aerosols. Transfer was more efficient in second- and third-generation EC products and increased as power increased. Selenium and arsenic were the most cytotoxic of the elements tested in the 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide assay. Selenium tetrachloride-induced oxidative stress in BEAS-2B cells, but not in human pulmonary fibroblasts. All fluids contained selenium above the concentration that induced oxidative stress in human bronchial epithelial cells. Selenium increased superoxide in mitochondria and nucleoli and increased selenoprotein H, a redox responsive DNA-binding protein that is upregulated by superoxide and an indicator of nucleolar stress. EC users are exposed to elements in aerosols, which may with chronic exposure contribute to diseases associated with oxidative stress. |
format | Online Article Text |
id | pubmed-7737483 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-77374832020-12-17 Chemical Elements in Electronic Cigarette Solvents and Aerosols Inhibit Mitochondrial Reductases and Induce Oxidative Stress Williams, Monique Ventura, Jesse Loza, Antonio Wang, Yuhuan Talbot, Prue Nicotine Tob Res Pre-clinical Toxicity Studies of Electronic Nicotine Delivery Systems (ENDS) and Constituents INTRODUCTION: Chemical elements and their toxicity were evaluated in electronic cigarette (EC) solvents, fluids, and aerosols. AIMS AND METHODS: Element identification and quantification in propylene glycol (PG), glycerin (G), refill fluids before and after use, and aerosols was done using inductively coupled plasma optical emission spectrometry. Cytotoxicity and oxidative stress were evaluated using in vitro assays. RESULTS: Seven elements were present in PG, G, and popular refill fluids, and they transferred to aerosols made with ECs. Selenium was in all products (0.125–0.292 mg/L), while arsenic, aluminum, and tin were frequently in solvent and refill fluid samples at lower concentrations. Iron, chromium, copper, nickel, zinc, and lead were only detected in fluid after EC use, indicating they came from heated atomizers. Elements transferred most efficiently to aerosols made with second-/third-generation ECs. Of the elements in fluid, selenium and arsenic were the most cytotoxic to human bronchial epithelial cells (BEAS-2B) and pulmonary fibroblasts in the 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide assay. Selenium increased superoxide production in mitochondria and nucleoli and elevated selenoprotein H in nucleoli of BEAS-2B cells at concentrations found in EC aerosols (10 nM or 0.002 mg/L). CONCLUSIONS: Elements in EC aerosols came from both e-fluids and atomizing units. Within second-/third-generation products, transfer became more efficient as power increased. In vitro responses occurred at concentrations of selenium found in some EC aerosols. Human exposure to chemical elements in ECs could be reduced by regulating (decreasing) allowable EC power and by improving the purity of PG and G. IMPLICATIONS: PG, G, refill fluids, and e-fluids contained potentially toxic chemical elements that transferred to aerosols. Transfer was more efficient in second- and third-generation EC products and increased as power increased. Selenium and arsenic were the most cytotoxic of the elements tested in the 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide assay. Selenium tetrachloride-induced oxidative stress in BEAS-2B cells, but not in human pulmonary fibroblasts. All fluids contained selenium above the concentration that induced oxidative stress in human bronchial epithelial cells. Selenium increased superoxide in mitochondria and nucleoli and increased selenoprotein H, a redox responsive DNA-binding protein that is upregulated by superoxide and an indicator of nucleolar stress. EC users are exposed to elements in aerosols, which may with chronic exposure contribute to diseases associated with oxidative stress. Oxford University Press 2020-12-15 /pmc/articles/PMC7737483/ /pubmed/33320250 http://dx.doi.org/10.1093/ntr/ntaa193 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Pre-clinical Toxicity Studies of Electronic Nicotine Delivery Systems (ENDS) and Constituents Williams, Monique Ventura, Jesse Loza, Antonio Wang, Yuhuan Talbot, Prue Chemical Elements in Electronic Cigarette Solvents and Aerosols Inhibit Mitochondrial Reductases and Induce Oxidative Stress |
title | Chemical Elements in Electronic Cigarette Solvents and Aerosols Inhibit Mitochondrial Reductases and Induce Oxidative Stress |
title_full | Chemical Elements in Electronic Cigarette Solvents and Aerosols Inhibit Mitochondrial Reductases and Induce Oxidative Stress |
title_fullStr | Chemical Elements in Electronic Cigarette Solvents and Aerosols Inhibit Mitochondrial Reductases and Induce Oxidative Stress |
title_full_unstemmed | Chemical Elements in Electronic Cigarette Solvents and Aerosols Inhibit Mitochondrial Reductases and Induce Oxidative Stress |
title_short | Chemical Elements in Electronic Cigarette Solvents and Aerosols Inhibit Mitochondrial Reductases and Induce Oxidative Stress |
title_sort | chemical elements in electronic cigarette solvents and aerosols inhibit mitochondrial reductases and induce oxidative stress |
topic | Pre-clinical Toxicity Studies of Electronic Nicotine Delivery Systems (ENDS) and Constituents |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7737483/ https://www.ncbi.nlm.nih.gov/pubmed/33320250 http://dx.doi.org/10.1093/ntr/ntaa193 |
work_keys_str_mv | AT williamsmonique chemicalelementsinelectroniccigarettesolventsandaerosolsinhibitmitochondrialreductasesandinduceoxidativestress AT venturajesse chemicalelementsinelectroniccigarettesolventsandaerosolsinhibitmitochondrialreductasesandinduceoxidativestress AT lozaantonio chemicalelementsinelectroniccigarettesolventsandaerosolsinhibitmitochondrialreductasesandinduceoxidativestress AT wangyuhuan chemicalelementsinelectroniccigarettesolventsandaerosolsinhibitmitochondrialreductasesandinduceoxidativestress AT talbotprue chemicalelementsinelectroniccigarettesolventsandaerosolsinhibitmitochondrialreductasesandinduceoxidativestress |