Cargando…
Using Image Registration and Machine Learning to Develop a Workstation Tool for Rapid Analysis of Glomeruli in Medical Renal Biopsies
BACKGROUND: Prescreening of biopsies has the potential to improve pathologists' workflow. Tools that identify features and display results in a visually thoughtful manner can enhance efficiency, accuracy, and reproducibility. Machine learning for detection of glomeruli ensures comprehensive ass...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7737496/ https://www.ncbi.nlm.nih.gov/pubmed/33343997 http://dx.doi.org/10.4103/jpi.jpi_49_20 |
_version_ | 1783622952592343040 |
---|---|
author | Wilbur, David C. Pettus, Jason R. Smith, Maxwell L. Cornell, Lynn D. Andryushkin, Alexander Wingard, Richard Wirch, Eric |
author_facet | Wilbur, David C. Pettus, Jason R. Smith, Maxwell L. Cornell, Lynn D. Andryushkin, Alexander Wingard, Richard Wirch, Eric |
author_sort | Wilbur, David C. |
collection | PubMed |
description | BACKGROUND: Prescreening of biopsies has the potential to improve pathologists' workflow. Tools that identify features and display results in a visually thoughtful manner can enhance efficiency, accuracy, and reproducibility. Machine learning for detection of glomeruli ensures comprehensive assessment and registration of four different stains allows for simultaneous navigation and viewing. METHODS: Medical renal core biopsies (4 stains each) were digitized using a Leica SCN400 at ×40 and loaded into the Corista Quantum research platform. Glomeruli were manually annotated by pathologists. The tissue on the 4 stains was registered using a combination of keypoint- and intensity-based algorithms, and a 4-panel simultaneous viewing display was created. Using a training cohort, machine learning convolutional neural net (CNN) models were created to identify glomeruli in all stains, and merged into composite fields of views (FOVs). The sensitivity and specificity of glomerulus detection, and FOV area for each detection were calculated. RESULTS: Forty-one biopsies were used for training (28) and same-batch evaluation (6). Seven additional biopsies from a temporally different batch were also evaluated. A variant of AlexNet CNN, used for object recognition, showed the best result for the detection of glomeruli with same-batch and different-batch evaluation: Same-batch sensitivity 92%, “modified” specificity 89%, average FOV size represented 0.8% of the total slide area; different-batch sensitivity 90%, “modified” specificity 98% and average FOV size 1.6% of the total slide area. CONCLUSIONS: Glomerulus detection in the best CNN model shows that machine learning algorithms may be accurate for this task. The added benefit of biopsy registration with simultaneous display and navigation allows reviewers to move from one machine-generated FOV to the next in all 4 stains. Together these features could increase both efficiency and accuracy in the review process. |
format | Online Article Text |
id | pubmed-7737496 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-77374962020-12-18 Using Image Registration and Machine Learning to Develop a Workstation Tool for Rapid Analysis of Glomeruli in Medical Renal Biopsies Wilbur, David C. Pettus, Jason R. Smith, Maxwell L. Cornell, Lynn D. Andryushkin, Alexander Wingard, Richard Wirch, Eric J Pathol Inform Original Article BACKGROUND: Prescreening of biopsies has the potential to improve pathologists' workflow. Tools that identify features and display results in a visually thoughtful manner can enhance efficiency, accuracy, and reproducibility. Machine learning for detection of glomeruli ensures comprehensive assessment and registration of four different stains allows for simultaneous navigation and viewing. METHODS: Medical renal core biopsies (4 stains each) were digitized using a Leica SCN400 at ×40 and loaded into the Corista Quantum research platform. Glomeruli were manually annotated by pathologists. The tissue on the 4 stains was registered using a combination of keypoint- and intensity-based algorithms, and a 4-panel simultaneous viewing display was created. Using a training cohort, machine learning convolutional neural net (CNN) models were created to identify glomeruli in all stains, and merged into composite fields of views (FOVs). The sensitivity and specificity of glomerulus detection, and FOV area for each detection were calculated. RESULTS: Forty-one biopsies were used for training (28) and same-batch evaluation (6). Seven additional biopsies from a temporally different batch were also evaluated. A variant of AlexNet CNN, used for object recognition, showed the best result for the detection of glomeruli with same-batch and different-batch evaluation: Same-batch sensitivity 92%, “modified” specificity 89%, average FOV size represented 0.8% of the total slide area; different-batch sensitivity 90%, “modified” specificity 98% and average FOV size 1.6% of the total slide area. CONCLUSIONS: Glomerulus detection in the best CNN model shows that machine learning algorithms may be accurate for this task. The added benefit of biopsy registration with simultaneous display and navigation allows reviewers to move from one machine-generated FOV to the next in all 4 stains. Together these features could increase both efficiency and accuracy in the review process. Wolters Kluwer - Medknow 2020-11-07 /pmc/articles/PMC7737496/ /pubmed/33343997 http://dx.doi.org/10.4103/jpi.jpi_49_20 Text en Copyright: © 2020 Journal of Pathology Informatics http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Wilbur, David C. Pettus, Jason R. Smith, Maxwell L. Cornell, Lynn D. Andryushkin, Alexander Wingard, Richard Wirch, Eric Using Image Registration and Machine Learning to Develop a Workstation Tool for Rapid Analysis of Glomeruli in Medical Renal Biopsies |
title | Using Image Registration and Machine Learning to Develop a Workstation Tool for Rapid Analysis of Glomeruli in Medical Renal Biopsies |
title_full | Using Image Registration and Machine Learning to Develop a Workstation Tool for Rapid Analysis of Glomeruli in Medical Renal Biopsies |
title_fullStr | Using Image Registration and Machine Learning to Develop a Workstation Tool for Rapid Analysis of Glomeruli in Medical Renal Biopsies |
title_full_unstemmed | Using Image Registration and Machine Learning to Develop a Workstation Tool for Rapid Analysis of Glomeruli in Medical Renal Biopsies |
title_short | Using Image Registration and Machine Learning to Develop a Workstation Tool for Rapid Analysis of Glomeruli in Medical Renal Biopsies |
title_sort | using image registration and machine learning to develop a workstation tool for rapid analysis of glomeruli in medical renal biopsies |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7737496/ https://www.ncbi.nlm.nih.gov/pubmed/33343997 http://dx.doi.org/10.4103/jpi.jpi_49_20 |
work_keys_str_mv | AT wilburdavidc usingimageregistrationandmachinelearningtodevelopaworkstationtoolforrapidanalysisofglomeruliinmedicalrenalbiopsies AT pettusjasonr usingimageregistrationandmachinelearningtodevelopaworkstationtoolforrapidanalysisofglomeruliinmedicalrenalbiopsies AT smithmaxwelll usingimageregistrationandmachinelearningtodevelopaworkstationtoolforrapidanalysisofglomeruliinmedicalrenalbiopsies AT cornelllynnd usingimageregistrationandmachinelearningtodevelopaworkstationtoolforrapidanalysisofglomeruliinmedicalrenalbiopsies AT andryushkinalexander usingimageregistrationandmachinelearningtodevelopaworkstationtoolforrapidanalysisofglomeruliinmedicalrenalbiopsies AT wingardrichard usingimageregistrationandmachinelearningtodevelopaworkstationtoolforrapidanalysisofglomeruliinmedicalrenalbiopsies AT wircheric usingimageregistrationandmachinelearningtodevelopaworkstationtoolforrapidanalysisofglomeruliinmedicalrenalbiopsies |