Cargando…

Predictive value of Alberta stroke program early CT score for perfusion weighted imaging - diffusion weighted imaging mismatch in stroke with middle cerebral artery occlusion

This study aimed to quantitatively assess the consistency and correlation between perfusion weighted imaging (PWI)/ diffusion weighted imaging (DWI) Alberta Stroke Program Early CT Score (ASPECTS) mismatch and PWI/DWI mismatch. Sixty-eight acute ischemic stroke with middle cerebral artery occlusion...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Kaixi, Gu, Baodong, Zuo, Taosheng, Xu, Xingru, Chen, Yu-Chen, Yin, Xindao, Feng, Guangkui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7738142/
https://www.ncbi.nlm.nih.gov/pubmed/33327283
http://dx.doi.org/10.1097/MD.0000000000023490
Descripción
Sumario:This study aimed to quantitatively assess the consistency and correlation between perfusion weighted imaging (PWI)/ diffusion weighted imaging (DWI) Alberta Stroke Program Early CT Score (ASPECTS) mismatch and PWI/DWI mismatch. Sixty-eight acute ischemic stroke with middle cerebral artery occlusion who underwent magnetic resonance imaging before thrombectomy were eligible. DWI volume, PWI volume and PWI-DWI mismatch were measured. DWI-, PWI-, PWI-DWI ASPECTS were evaluated. Statistical analysis was performed to compare the correlation between volume and ASPECTS of DWI-, PWI- and PWI-DWI mismatch. Receiver operating characteristic curve analysis was used to assess the predictive value of the PWI-DWI ASPECTS mismatch for the occurrence of PWI-DWI mismatch in acute ischemic stroke patients with middle cerebral artery occlusion. Of 68 patients, the DWI volume, PWI volume and PWI-DWI mismatch volume were (27.76 ± 17.53) mL, (167.09 ± 59.64) mL and (139.33 ± 58.18) mL respectively. DWI-ASPECTS was 6.75 ± 1.90 with the interobserver agreement was κ=0.98 (95% CI, 0.95–0.99); PWI-ASPECTS was 3.09 ± 2.11 with the interobserver agreement was κ=0.95 (95% CI, 0.91–0.99); PWI-DWI ASPECTS mismatch was 6.75 ± 1.90. Spearman's rank correlation analysis revealed that PWI-DWI mismatch volume was negatively correlated with PWI-DWI ASPECTS mismatch (r = −0.802; P = .000). Receiver operating characteristic analysis showed that when the PWI-DWI ASPECTS mismatch cut point was ≥ 2, the under curve of PWI-DWI ASPECTS mismatch for predicting PWI-DWI mismatch was 0.954 (95%CI, 0.911–0.998), with the sensitivity and specificity were 84.00% and 100% respectively. PWI-DWI ASPECTS mismatch may represent a convenient surrogate for penumbra in clinical trials.