Cargando…

The Effect of Ankle Foot Orthosis' Design and Degree of Dorsiflexion on Achilles Tendon Biomechanics—Tendon Displacement, Lower Leg Muscle Activation, and Plantar Pressure During Walking

Background: Following an Achilles tendon rupture, ankle foot orthoses (AFO) of different designs are used to protect the healing tendon. They are generally designed to protect against re-rupture by preventing undesired dorsiflexion and to prevent elongation by achieving plantarflexion in the ankle....

Descripción completa

Detalles Bibliográficos
Autores principales: Fröberg, Åsa, Mårtensson, Mattias, Arndt, Anton
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7739684/
https://www.ncbi.nlm.nih.gov/pubmed/33345010
http://dx.doi.org/10.3389/fspor.2020.00016
_version_ 1783623375418032128
author Fröberg, Åsa
Mårtensson, Mattias
Arndt, Anton
author_facet Fröberg, Åsa
Mårtensson, Mattias
Arndt, Anton
author_sort Fröberg, Åsa
collection PubMed
description Background: Following an Achilles tendon rupture, ankle foot orthoses (AFO) of different designs are used to protect the healing tendon. They are generally designed to protect against re-rupture by preventing undesired dorsiflexion and to prevent elongation by achieving plantarflexion in the ankle. There is limited knowledge of the biomechanical effects of different AFO designs and ankle angles on the tendon and lower leg muscles. Hypothesis: The hypothesis was that non-uniform displacement in the Achilles tendon, lower leg muscle activity, and plantar pressure distribution would be affected differently in different designs of AFO and by varying the degree of dorsiflexion limitation. Study Design: Controlled laboratory study. Methods: Ultrasound of the Achilles tendon, EMG of the lower leg muscles and plantar pressure distribution were recorded in 16 healthy subjects during walking on a treadmill unbraced and wearing three designs of AFO. Ultrasound speckle tracking was used to estimate motion within the tendon. The tested AFO designs were a rigid AFO and a dorsal brace used together with wedges and an AFO with an adjustable ankle angle restricting dorsiflexion to various degrees. Results: There were no significant differences in non-uniform tendon displacement or muscle activity between the different designs of AFO. For the rigid AFO and the adjustable AFO there was a significant reduction in non-uniform displacement within the tendon and soleus muscle activity as restriction in dorsiflexion increased. Conclusion: The degree of dorsiflexion allowed within an AFO had greater effects on Achilles tendon displacement patterns and muscle activity in the calf than differences in AFO design. AFO settings that allowed ankle dorsiflexion to neutral resulted in displacement patterns in the Achilles tendon and muscle activity in the lower leg which were close to those observed during unbraced walking.
format Online
Article
Text
id pubmed-7739684
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-77396842020-12-17 The Effect of Ankle Foot Orthosis' Design and Degree of Dorsiflexion on Achilles Tendon Biomechanics—Tendon Displacement, Lower Leg Muscle Activation, and Plantar Pressure During Walking Fröberg, Åsa Mårtensson, Mattias Arndt, Anton Front Sports Act Living Sports and Active Living Background: Following an Achilles tendon rupture, ankle foot orthoses (AFO) of different designs are used to protect the healing tendon. They are generally designed to protect against re-rupture by preventing undesired dorsiflexion and to prevent elongation by achieving plantarflexion in the ankle. There is limited knowledge of the biomechanical effects of different AFO designs and ankle angles on the tendon and lower leg muscles. Hypothesis: The hypothesis was that non-uniform displacement in the Achilles tendon, lower leg muscle activity, and plantar pressure distribution would be affected differently in different designs of AFO and by varying the degree of dorsiflexion limitation. Study Design: Controlled laboratory study. Methods: Ultrasound of the Achilles tendon, EMG of the lower leg muscles and plantar pressure distribution were recorded in 16 healthy subjects during walking on a treadmill unbraced and wearing three designs of AFO. Ultrasound speckle tracking was used to estimate motion within the tendon. The tested AFO designs were a rigid AFO and a dorsal brace used together with wedges and an AFO with an adjustable ankle angle restricting dorsiflexion to various degrees. Results: There were no significant differences in non-uniform tendon displacement or muscle activity between the different designs of AFO. For the rigid AFO and the adjustable AFO there was a significant reduction in non-uniform displacement within the tendon and soleus muscle activity as restriction in dorsiflexion increased. Conclusion: The degree of dorsiflexion allowed within an AFO had greater effects on Achilles tendon displacement patterns and muscle activity in the calf than differences in AFO design. AFO settings that allowed ankle dorsiflexion to neutral resulted in displacement patterns in the Achilles tendon and muscle activity in the lower leg which were close to those observed during unbraced walking. Frontiers Media S.A. 2020-03-17 /pmc/articles/PMC7739684/ /pubmed/33345010 http://dx.doi.org/10.3389/fspor.2020.00016 Text en Copyright © 2020 Fröberg, Mårtensson and Arndt. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Sports and Active Living
Fröberg, Åsa
Mårtensson, Mattias
Arndt, Anton
The Effect of Ankle Foot Orthosis' Design and Degree of Dorsiflexion on Achilles Tendon Biomechanics—Tendon Displacement, Lower Leg Muscle Activation, and Plantar Pressure During Walking
title The Effect of Ankle Foot Orthosis' Design and Degree of Dorsiflexion on Achilles Tendon Biomechanics—Tendon Displacement, Lower Leg Muscle Activation, and Plantar Pressure During Walking
title_full The Effect of Ankle Foot Orthosis' Design and Degree of Dorsiflexion on Achilles Tendon Biomechanics—Tendon Displacement, Lower Leg Muscle Activation, and Plantar Pressure During Walking
title_fullStr The Effect of Ankle Foot Orthosis' Design and Degree of Dorsiflexion on Achilles Tendon Biomechanics—Tendon Displacement, Lower Leg Muscle Activation, and Plantar Pressure During Walking
title_full_unstemmed The Effect of Ankle Foot Orthosis' Design and Degree of Dorsiflexion on Achilles Tendon Biomechanics—Tendon Displacement, Lower Leg Muscle Activation, and Plantar Pressure During Walking
title_short The Effect of Ankle Foot Orthosis' Design and Degree of Dorsiflexion on Achilles Tendon Biomechanics—Tendon Displacement, Lower Leg Muscle Activation, and Plantar Pressure During Walking
title_sort effect of ankle foot orthosis' design and degree of dorsiflexion on achilles tendon biomechanics—tendon displacement, lower leg muscle activation, and plantar pressure during walking
topic Sports and Active Living
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7739684/
https://www.ncbi.nlm.nih.gov/pubmed/33345010
http://dx.doi.org/10.3389/fspor.2020.00016
work_keys_str_mv AT frobergasa theeffectofanklefootorthosisdesignanddegreeofdorsiflexiononachillestendonbiomechanicstendondisplacementlowerlegmuscleactivationandplantarpressureduringwalking
AT martenssonmattias theeffectofanklefootorthosisdesignanddegreeofdorsiflexiononachillestendonbiomechanicstendondisplacementlowerlegmuscleactivationandplantarpressureduringwalking
AT arndtanton theeffectofanklefootorthosisdesignanddegreeofdorsiflexiononachillestendonbiomechanicstendondisplacementlowerlegmuscleactivationandplantarpressureduringwalking
AT frobergasa effectofanklefootorthosisdesignanddegreeofdorsiflexiononachillestendonbiomechanicstendondisplacementlowerlegmuscleactivationandplantarpressureduringwalking
AT martenssonmattias effectofanklefootorthosisdesignanddegreeofdorsiflexiononachillestendonbiomechanicstendondisplacementlowerlegmuscleactivationandplantarpressureduringwalking
AT arndtanton effectofanklefootorthosisdesignanddegreeofdorsiflexiononachillestendonbiomechanicstendondisplacementlowerlegmuscleactivationandplantarpressureduringwalking