Cargando…
Cone-Beam CT Image Guidance With and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions
Bronchoscopic diagnosis of small peripheral lung lesions suspected of lung cancer remains a challenge. A successful endobronchial diagnosis comprises navigation, confirmation, and tissue acquisition. In all steps, 3-dimensional information is essential. Cone-beam computed tomography (CBCT) imaging c...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7742216/ https://www.ncbi.nlm.nih.gov/pubmed/32649327 http://dx.doi.org/10.1097/LBR.0000000000000697 |
_version_ | 1783623935685820416 |
---|---|
author | Verhoeven, Roel L.J. Fütterer, Jurgen J. Hoefsloot, Wouter van der Heijden, Erik H.F.M. |
author_facet | Verhoeven, Roel L.J. Fütterer, Jurgen J. Hoefsloot, Wouter van der Heijden, Erik H.F.M. |
author_sort | Verhoeven, Roel L.J. |
collection | PubMed |
description | Bronchoscopic diagnosis of small peripheral lung lesions suspected of lung cancer remains a challenge. A successful endobronchial diagnosis comprises navigation, confirmation, and tissue acquisition. In all steps, 3-dimensional information is essential. Cone-beam computed tomography (CBCT) imaging can provide computed tomography information and 3-dimensional augmented fluoroscopy imaging. We assessed whether CBCT imaging can improve navigation and diagnosis of peripheral lesions by 2 clinical workflows with a cross-over design: (1) a primary CBCT and radial endobronchial ultrasound mini probe imaging–based approach and (2) a primary electromagnetic navigation (EMN) and radial endobronchial ultrasound mini probe imaging–based approach. METHODS: All patients with a peripheral lung lesion biopsy indication were eligible for study inclusion and randomly assigned to study arms. Commercially available equipment was used. The main study goals were to assess CBCT-confirmed navigation success and diagnostic accuracy. Surgery or unambiguous clinical follow-up served as the gold standard. RESULTS: Eighty-seven patients with 107 lesions were included. Lesion mean longest axis size in the CBCT arm was 16.6 mm (n=47) and 14.2 mm in the EMN arm (n=40). The primary CBCT approach and primary EMN approach had 76.3% and 52.2% navigation success, respectively. Addition of EMN to the CBCT approach increased navigation success to 89.9%. Addition of CBCT imaging to the EMN approach significantly increased navigation success to 87.5% per lesion. The overall diagnostic accuracy per patient was significantly lower than the navigation success, being 72.4%. CONCLUSION: CBCT imaging is a valuable addition to navigation bronchoscopy. Although overall navigation success was high, the diagnostic accuracy remains to be improved. Future research should focus on improving the tissue acquisition methodology. |
format | Online Article Text |
id | pubmed-7742216 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-77422162020-12-22 Cone-Beam CT Image Guidance With and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions Verhoeven, Roel L.J. Fütterer, Jurgen J. Hoefsloot, Wouter van der Heijden, Erik H.F.M. J Bronchology Interv Pulmonol Original Investigations Bronchoscopic diagnosis of small peripheral lung lesions suspected of lung cancer remains a challenge. A successful endobronchial diagnosis comprises navigation, confirmation, and tissue acquisition. In all steps, 3-dimensional information is essential. Cone-beam computed tomography (CBCT) imaging can provide computed tomography information and 3-dimensional augmented fluoroscopy imaging. We assessed whether CBCT imaging can improve navigation and diagnosis of peripheral lesions by 2 clinical workflows with a cross-over design: (1) a primary CBCT and radial endobronchial ultrasound mini probe imaging–based approach and (2) a primary electromagnetic navigation (EMN) and radial endobronchial ultrasound mini probe imaging–based approach. METHODS: All patients with a peripheral lung lesion biopsy indication were eligible for study inclusion and randomly assigned to study arms. Commercially available equipment was used. The main study goals were to assess CBCT-confirmed navigation success and diagnostic accuracy. Surgery or unambiguous clinical follow-up served as the gold standard. RESULTS: Eighty-seven patients with 107 lesions were included. Lesion mean longest axis size in the CBCT arm was 16.6 mm (n=47) and 14.2 mm in the EMN arm (n=40). The primary CBCT approach and primary EMN approach had 76.3% and 52.2% navigation success, respectively. Addition of EMN to the CBCT approach increased navigation success to 89.9%. Addition of CBCT imaging to the EMN approach significantly increased navigation success to 87.5% per lesion. The overall diagnostic accuracy per patient was significantly lower than the navigation success, being 72.4%. CONCLUSION: CBCT imaging is a valuable addition to navigation bronchoscopy. Although overall navigation success was high, the diagnostic accuracy remains to be improved. Future research should focus on improving the tissue acquisition methodology. Lippincott Williams & Wilkins 2021-01 2020-07-08 /pmc/articles/PMC7742216/ /pubmed/32649327 http://dx.doi.org/10.1097/LBR.0000000000000697 Text en Copyright © 2020 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Original Investigations Verhoeven, Roel L.J. Fütterer, Jurgen J. Hoefsloot, Wouter van der Heijden, Erik H.F.M. Cone-Beam CT Image Guidance With and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions |
title | Cone-Beam CT Image Guidance With and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions |
title_full | Cone-Beam CT Image Guidance With and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions |
title_fullStr | Cone-Beam CT Image Guidance With and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions |
title_full_unstemmed | Cone-Beam CT Image Guidance With and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions |
title_short | Cone-Beam CT Image Guidance With and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions |
title_sort | cone-beam ct image guidance with and without electromagnetic navigation bronchoscopy for biopsy of peripheral pulmonary lesions |
topic | Original Investigations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7742216/ https://www.ncbi.nlm.nih.gov/pubmed/32649327 http://dx.doi.org/10.1097/LBR.0000000000000697 |
work_keys_str_mv | AT verhoevenroellj conebeamctimageguidancewithandwithoutelectromagneticnavigationbronchoscopyforbiopsyofperipheralpulmonarylesions AT futtererjurgenj conebeamctimageguidancewithandwithoutelectromagneticnavigationbronchoscopyforbiopsyofperipheralpulmonarylesions AT hoefslootwouter conebeamctimageguidancewithandwithoutelectromagneticnavigationbronchoscopyforbiopsyofperipheralpulmonarylesions AT vanderheijdenerikhfm conebeamctimageguidancewithandwithoutelectromagneticnavigationbronchoscopyforbiopsyofperipheralpulmonarylesions |