Cargando…
Imaging of enthesitis by an LED-based photoacoustic system
Significance: One key pathological characteristic of seronegative spondyloarthropathy (SpA) is inflammation at the insertion of tendons and ligaments into the bone (enthesitis). Aim: We explore the potential of the emerging photoacoustic (PA) imaging in diagnosis of SpA and review its feasibility in...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7744251/ https://www.ncbi.nlm.nih.gov/pubmed/33331148 http://dx.doi.org/10.1117/1.JBO.25.12.126005 |
_version_ | 1783624398361591808 |
---|---|
author | Jo, Janggun Xu, Guan Schiopu, Elena Chamberland, David Gandikota, Girish Wang, Xueding |
author_facet | Jo, Janggun Xu, Guan Schiopu, Elena Chamberland, David Gandikota, Girish Wang, Xueding |
author_sort | Jo, Janggun |
collection | PubMed |
description | Significance: One key pathological characteristic of seronegative spondyloarthropathy (SpA) is inflammation at the insertion of tendons and ligaments into the bone (enthesitis). Aim: We explore the potential of the emerging photoacoustic (PA) imaging in diagnosis of SpA and review its feasibility in detecting SpA-associated Achilles tendon enthesitis. Approach: A light-emitting diode (LED)-based PA and ultrasound combined system was employed. The PA images, both along the long and the short axes of each Achilles tendon insertion region, were acquired at 850-nm wavelength, which is sensitive in depicting increased blood volume (i.e., hyperemia). To assess the hyperemia indicating enthesis inflammation, two parameters were quantified in the imaged tendons, including the average intensity and the density of the color pixels in the pseudo-color PA images. Ten SpA patients, all of which met Assessment of SpA International Society (ASAS) criteria for SpA and were found to have Achilles enthesitis by clinical exam according to a board-certified rheumatologist, were included in the study. Results: The PA and Doppler ultrasound imaging of Achilles enthesitis resulting from these 10 SpA patients were compared to those from 10 healthy volunteers, leading to statistically significant differences ([Formula: see text]) in the applied [Formula: see text]-tests. Conclusions: This preliminary clinical study suggests that the LED-based PA imaging holds a promise for sensitive and objective assessment of SpA enthesitis in an outpatient setting of the rheumatology clinic. |
format | Online Article Text |
id | pubmed-7744251 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-77442512020-12-17 Imaging of enthesitis by an LED-based photoacoustic system Jo, Janggun Xu, Guan Schiopu, Elena Chamberland, David Gandikota, Girish Wang, Xueding J Biomed Opt Imaging Significance: One key pathological characteristic of seronegative spondyloarthropathy (SpA) is inflammation at the insertion of tendons and ligaments into the bone (enthesitis). Aim: We explore the potential of the emerging photoacoustic (PA) imaging in diagnosis of SpA and review its feasibility in detecting SpA-associated Achilles tendon enthesitis. Approach: A light-emitting diode (LED)-based PA and ultrasound combined system was employed. The PA images, both along the long and the short axes of each Achilles tendon insertion region, were acquired at 850-nm wavelength, which is sensitive in depicting increased blood volume (i.e., hyperemia). To assess the hyperemia indicating enthesis inflammation, two parameters were quantified in the imaged tendons, including the average intensity and the density of the color pixels in the pseudo-color PA images. Ten SpA patients, all of which met Assessment of SpA International Society (ASAS) criteria for SpA and were found to have Achilles enthesitis by clinical exam according to a board-certified rheumatologist, were included in the study. Results: The PA and Doppler ultrasound imaging of Achilles enthesitis resulting from these 10 SpA patients were compared to those from 10 healthy volunteers, leading to statistically significant differences ([Formula: see text]) in the applied [Formula: see text]-tests. Conclusions: This preliminary clinical study suggests that the LED-based PA imaging holds a promise for sensitive and objective assessment of SpA enthesitis in an outpatient setting of the rheumatology clinic. Society of Photo-Optical Instrumentation Engineers 2020-12-17 2020-12 /pmc/articles/PMC7744251/ /pubmed/33331148 http://dx.doi.org/10.1117/1.JBO.25.12.126005 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Imaging Jo, Janggun Xu, Guan Schiopu, Elena Chamberland, David Gandikota, Girish Wang, Xueding Imaging of enthesitis by an LED-based photoacoustic system |
title | Imaging of enthesitis by an LED-based photoacoustic system |
title_full | Imaging of enthesitis by an LED-based photoacoustic system |
title_fullStr | Imaging of enthesitis by an LED-based photoacoustic system |
title_full_unstemmed | Imaging of enthesitis by an LED-based photoacoustic system |
title_short | Imaging of enthesitis by an LED-based photoacoustic system |
title_sort | imaging of enthesitis by an led-based photoacoustic system |
topic | Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7744251/ https://www.ncbi.nlm.nih.gov/pubmed/33331148 http://dx.doi.org/10.1117/1.JBO.25.12.126005 |
work_keys_str_mv | AT jojanggun imagingofenthesitisbyanledbasedphotoacousticsystem AT xuguan imagingofenthesitisbyanledbasedphotoacousticsystem AT schiopuelena imagingofenthesitisbyanledbasedphotoacousticsystem AT chamberlanddavid imagingofenthesitisbyanledbasedphotoacousticsystem AT gandikotagirish imagingofenthesitisbyanledbasedphotoacousticsystem AT wangxueding imagingofenthesitisbyanledbasedphotoacousticsystem |