Cargando…

High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction?

The surgical technique of proximal tibial osteotomy for genu varum in adults has evolved from a procedure using closing wedges of estimated sizes with staple fixation in the 1960s to using standard trauma internal fixation implants and, more recently, to gradual correction with software-guided hexap...

Descripción completa

Detalles Bibliográficos
Autores principales: Solomin, LN, Chugaev, DV, Filippova, AV, Kulesh, PN
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7744664/
https://www.ncbi.nlm.nih.gov/pubmed/33363636
http://dx.doi.org/10.5005/jp-journals-10080-1449
_version_ 1783624469330264064
author Solomin, LN
Chugaev, DV
Filippova, AV
Kulesh, PN
author_facet Solomin, LN
Chugaev, DV
Filippova, AV
Kulesh, PN
author_sort Solomin, LN
collection PubMed
description The surgical technique of proximal tibial osteotomy for genu varum in adults has evolved from a procedure using closing wedges of estimated sizes with staple fixation in the 1960s to using standard trauma internal fixation implants and, more recently, to gradual correction with software-guided hexapod external fixators. In the last two decades, implant manufacturers have also produced anatomical implants specific for such corrective osteotomies. This study evaluates the limits of using such proprietary implants for proximal tibial osteotomy in genu varum. MATERIALS AND METHODS: Scanograms (teleradiograms) of lower limbs of a patient were used to derive skiagrams (two-dimensional bony outlines of the extremities). From these, two-dimensional and three-dimensional models of varus deformities of the tibia with different values of mechanical medial proximal tibial angle (mMPTA, from 85° to 40°) were created. An analysis of the created deformity was carried out and a simulation for surgical correction was performed using an open wedge high tibial osteotomy with fixation using a proprietary (Tomofix, Synthes) implant. In addition, a 3D simulation technique was used to check the accuracy of the results obtained from the 2D simulation. RESULTS: In cases of mMPTA ≥80° with localisation of the apex of varus deformity at the level of the knee joint line, the standard technique used with the proprietary medial tibial plate produces good results. In cases of mMPTA ≤70°, fixation of the osteotomised fragments by the proprietary medial plate is poor owing to the anatomical contours of the implant. In these cases, a different type of osteosynthesis is needed. In cases of mMPTA ≤70°, the distance between the lower edge of the bone plate and the medial surface of the tibia after a proximal tibial osteotomy exceeds 11 mm and will result in unacceptable soft tissue tension around the implant. Mechanical axis deviation to the Fujisawa point produces mMPTA values outside the reference range of normal values. CONCLUSION: An osteotomy of the proximal tibia using a prescribed technique linked to a proprietary implant achieves good results only if performed within a certain range of deformity values. Pronounced varus deformities require a fundamentally different approach. This study reveals that surgeons undertaking corrective proximal tibial osteotomies for genu varum need to perform a comprehensive analysis of the deformity to allow for appropriate selection of patients. This will enable a consideration of the size and other characteristics of the deformity that will reduce the technical complications that may arise if the correction was performed using the recommended technique linked to a proprietary implant. HOW TO CITE THIS ARTICLE: Solomin LN, Chugaev DV, Filippova AV, et al. High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction? Strategies Trauma Limb Reconstr 2020;15(1):13–22.
format Online
Article
Text
id pubmed-7744664
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-77446642020-12-23 High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction? Solomin, LN Chugaev, DV Filippova, AV Kulesh, PN Strategies Trauma Limb Reconstr Original Article The surgical technique of proximal tibial osteotomy for genu varum in adults has evolved from a procedure using closing wedges of estimated sizes with staple fixation in the 1960s to using standard trauma internal fixation implants and, more recently, to gradual correction with software-guided hexapod external fixators. In the last two decades, implant manufacturers have also produced anatomical implants specific for such corrective osteotomies. This study evaluates the limits of using such proprietary implants for proximal tibial osteotomy in genu varum. MATERIALS AND METHODS: Scanograms (teleradiograms) of lower limbs of a patient were used to derive skiagrams (two-dimensional bony outlines of the extremities). From these, two-dimensional and three-dimensional models of varus deformities of the tibia with different values of mechanical medial proximal tibial angle (mMPTA, from 85° to 40°) were created. An analysis of the created deformity was carried out and a simulation for surgical correction was performed using an open wedge high tibial osteotomy with fixation using a proprietary (Tomofix, Synthes) implant. In addition, a 3D simulation technique was used to check the accuracy of the results obtained from the 2D simulation. RESULTS: In cases of mMPTA ≥80° with localisation of the apex of varus deformity at the level of the knee joint line, the standard technique used with the proprietary medial tibial plate produces good results. In cases of mMPTA ≤70°, fixation of the osteotomised fragments by the proprietary medial plate is poor owing to the anatomical contours of the implant. In these cases, a different type of osteosynthesis is needed. In cases of mMPTA ≤70°, the distance between the lower edge of the bone plate and the medial surface of the tibia after a proximal tibial osteotomy exceeds 11 mm and will result in unacceptable soft tissue tension around the implant. Mechanical axis deviation to the Fujisawa point produces mMPTA values outside the reference range of normal values. CONCLUSION: An osteotomy of the proximal tibia using a prescribed technique linked to a proprietary implant achieves good results only if performed within a certain range of deformity values. Pronounced varus deformities require a fundamentally different approach. This study reveals that surgeons undertaking corrective proximal tibial osteotomies for genu varum need to perform a comprehensive analysis of the deformity to allow for appropriate selection of patients. This will enable a consideration of the size and other characteristics of the deformity that will reduce the technical complications that may arise if the correction was performed using the recommended technique linked to a proprietary implant. HOW TO CITE THIS ARTICLE: Solomin LN, Chugaev DV, Filippova AV, et al. High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction? Strategies Trauma Limb Reconstr 2020;15(1):13–22. Jaypee Brothers Medical Publishers 2020 /pmc/articles/PMC7744664/ /pubmed/33363636 http://dx.doi.org/10.5005/jp-journals-10080-1449 Text en Copyright © 2020; Jaypee Brothers Medical Publishers (P) Ltd. © The Author(s). 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Article
Solomin, LN
Chugaev, DV
Filippova, AV
Kulesh, PN
High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction?
title High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction?
title_full High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction?
title_fullStr High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction?
title_full_unstemmed High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction?
title_short High Tibial Osteotomy for Genu Varum in Adults: Do Proprietary Implants Limit the Quality of Correction?
title_sort high tibial osteotomy for genu varum in adults: do proprietary implants limit the quality of correction?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7744664/
https://www.ncbi.nlm.nih.gov/pubmed/33363636
http://dx.doi.org/10.5005/jp-journals-10080-1449
work_keys_str_mv AT solominln hightibialosteotomyforgenuvaruminadultsdoproprietaryimplantslimitthequalityofcorrection
AT chugaevdv hightibialosteotomyforgenuvaruminadultsdoproprietaryimplantslimitthequalityofcorrection
AT filippovaav hightibialosteotomyforgenuvaruminadultsdoproprietaryimplantslimitthequalityofcorrection
AT kuleshpn hightibialosteotomyforgenuvaruminadultsdoproprietaryimplantslimitthequalityofcorrection