Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study

AIM: Metallic components from circular external fixators, including the Ilizarov frame, cause artefacts on X-rays and obstruct clear visualisation of bone detail. We evaluated the ability of tomosynthesis to reduce interference on radiographs caused by metal artefacts and developed an optimal image...

Descripción completa

Detalles Bibliográficos
Autores principales: Abe, Yuki, Shimada, Makoto, Takeda, Yoshihiro, Enoki, Taisuke, Omachi, Kumiko, Abe, Shuji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7744665/
https://www.ncbi.nlm.nih.gov/pubmed/33363634
http://dx.doi.org/10.5005/jp-journals-10080-1446
_version_ 1783624469552562176
author Abe, Yuki
Shimada, Makoto
Takeda, Yoshihiro
Enoki, Taisuke
Omachi, Kumiko
Abe, Shuji
author_facet Abe, Yuki
Shimada, Makoto
Takeda, Yoshihiro
Enoki, Taisuke
Omachi, Kumiko
Abe, Shuji
author_sort Abe, Yuki
collection PubMed
description AIM: Metallic components from circular external fixators, including the Ilizarov frame, cause artefacts on X-rays and obstruct clear visualisation of bone detail. We evaluated the ability of tomosynthesis to reduce interference on radiographs caused by metal artefacts and developed an optimal image acquisition method for such cases. MATERIALS AND METHODS: An Ilizarov frame phantom was constructed using rods placed on the bone for the purpose to evaluate the benefits of tomosynthesis. Distances between the rod and bone and the angle between the rod and X-ray tube orbit were set at three different levels. Filtered backprojection images were reconstructed using two different features of the reconstruction function: THICKNESS−− (CONTRAST4) and THICKNESS++ (METAL4); the first is suitable for improving contrast and the second is suitable for metal artefacts. The peak signal-to-noise ratio (PSNR) was used during image evaluation to determine the influence of the metallic rod on bone structure visibility. RESULTS: The PSNR increased as the angle between the metal rod and the X-ray tube orbit and the distance between the metallic rod and bone increased. The PSNR was larger when using THICKNESS−− (CONTRAST4) than when using THICKNESS++ (METAL4). CONCLUSION: The optimal reconstruction function and image acquisition determined using the metallic rod in this study suggest that quality equal to that without the metallic rod can be obtained. CLINICAL SIGNIFICANCE: We describe an optimised method for image acquisition without unnecessary acquisition repetition and unreasonable posture changes when the bone cannot be adequately visualised. HOW TO CITE THIS ARTICLE: Abe Y, Shimada M, Takeda Y, et al. Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study. Strategies Trauma Limb Reconstr 2020;15(1):1–6.
format Online
Article
Text
id pubmed-7744665
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-77446652020-12-23 Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study Abe, Yuki Shimada, Makoto Takeda, Yoshihiro Enoki, Taisuke Omachi, Kumiko Abe, Shuji Strategies Trauma Limb Reconstr Original Article AIM: Metallic components from circular external fixators, including the Ilizarov frame, cause artefacts on X-rays and obstruct clear visualisation of bone detail. We evaluated the ability of tomosynthesis to reduce interference on radiographs caused by metal artefacts and developed an optimal image acquisition method for such cases. MATERIALS AND METHODS: An Ilizarov frame phantom was constructed using rods placed on the bone for the purpose to evaluate the benefits of tomosynthesis. Distances between the rod and bone and the angle between the rod and X-ray tube orbit were set at three different levels. Filtered backprojection images were reconstructed using two different features of the reconstruction function: THICKNESS−− (CONTRAST4) and THICKNESS++ (METAL4); the first is suitable for improving contrast and the second is suitable for metal artefacts. The peak signal-to-noise ratio (PSNR) was used during image evaluation to determine the influence of the metallic rod on bone structure visibility. RESULTS: The PSNR increased as the angle between the metal rod and the X-ray tube orbit and the distance between the metallic rod and bone increased. The PSNR was larger when using THICKNESS−− (CONTRAST4) than when using THICKNESS++ (METAL4). CONCLUSION: The optimal reconstruction function and image acquisition determined using the metallic rod in this study suggest that quality equal to that without the metallic rod can be obtained. CLINICAL SIGNIFICANCE: We describe an optimised method for image acquisition without unnecessary acquisition repetition and unreasonable posture changes when the bone cannot be adequately visualised. HOW TO CITE THIS ARTICLE: Abe Y, Shimada M, Takeda Y, et al. Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study. Strategies Trauma Limb Reconstr 2020;15(1):1–6. Jaypee Brothers Medical Publishers 2020 /pmc/articles/PMC7744665/ /pubmed/33363634 http://dx.doi.org/10.5005/jp-journals-10080-1446 Text en Copyright © 2020; Jaypee Brothers Medical Publishers (P) Ltd. © The Author(s). 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Article
Abe, Yuki
Shimada, Makoto
Takeda, Yoshihiro
Enoki, Taisuke
Omachi, Kumiko
Abe, Shuji
Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study
title Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study
title_full Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study
title_fullStr Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study
title_full_unstemmed Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study
title_short Evaluation of Patient Positioning during Digital Tomosynthesis and Reconstruction Algorithms for Ilizarov Frames: A Phantom Study
title_sort evaluation of patient positioning during digital tomosynthesis and reconstruction algorithms for ilizarov frames: a phantom study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7744665/
https://www.ncbi.nlm.nih.gov/pubmed/33363634
http://dx.doi.org/10.5005/jp-journals-10080-1446
work_keys_str_mv AT abeyuki evaluationofpatientpositioningduringdigitaltomosynthesisandreconstructionalgorithmsforilizarovframesaphantomstudy
AT shimadamakoto evaluationofpatientpositioningduringdigitaltomosynthesisandreconstructionalgorithmsforilizarovframesaphantomstudy
AT takedayoshihiro evaluationofpatientpositioningduringdigitaltomosynthesisandreconstructionalgorithmsforilizarovframesaphantomstudy
AT enokitaisuke evaluationofpatientpositioningduringdigitaltomosynthesisandreconstructionalgorithmsforilizarovframesaphantomstudy
AT omachikumiko evaluationofpatientpositioningduringdigitaltomosynthesisandreconstructionalgorithmsforilizarovframesaphantomstudy
AT abeshuji evaluationofpatientpositioningduringdigitaltomosynthesisandreconstructionalgorithmsforilizarovframesaphantomstudy