Cargando…

Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single‐arm prospective interventional study

BACKGROUND: There is insufficient evidence for the efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors. OBJECTIVE: To verify the efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy, by evaluating masticatory performa...

Descripción completa

Detalles Bibliográficos
Autores principales: Yanamoto, Souichi, Soutome, Sakiko, Murata, Maho, Kawakita, Akiko, Yamaguchi, Erika, Yoshida, Kazuhiro, Kurogi, Tadafumi, Kuroshima, Shinichiro, Murata, Hiroshi, Sawase, Takashi, Umeda, Masahiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7745077/
https://www.ncbi.nlm.nih.gov/pubmed/32896981
http://dx.doi.org/10.1002/cre2.326
_version_ 1783624544732315648
author Yanamoto, Souichi
Soutome, Sakiko
Murata, Maho
Kawakita, Akiko
Yamaguchi, Erika
Yoshida, Kazuhiro
Kurogi, Tadafumi
Kuroshima, Shinichiro
Murata, Hiroshi
Sawase, Takashi
Umeda, Masahiro
author_facet Yanamoto, Souichi
Soutome, Sakiko
Murata, Maho
Kawakita, Akiko
Yamaguchi, Erika
Yoshida, Kazuhiro
Kurogi, Tadafumi
Kuroshima, Shinichiro
Murata, Hiroshi
Sawase, Takashi
Umeda, Masahiro
author_sort Yanamoto, Souichi
collection PubMed
description BACKGROUND: There is insufficient evidence for the efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors. OBJECTIVE: To verify the efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy, by evaluating masticatory performance and quality of life (QoL). METHODS: This was a single‐arm prospective interventional study, verifying the efficacy of silicone soft reliner (GC RELINE II®) on the maxillary obturator prosthesis. Data were obtained from a comparison of the endpoints after 14 days of continuous use of acrylic and silicone soft‐lined prostheses. The primary endpoint was masticatory performance. The secondary endpoints were occlusal performance and oral health‐related QoL (OHRQoL). The masticatory performance, occlusal performance, and OHRQoL were assessed by glucose concentration, maximum bite force, and the Japanese version of Oral Health Impact Profile (OHIP‐J49), respectively. RESULTS: This study included five patients (two males, three females), aged between 71 and 88 years, with a median of 74 years. The median of glucose concentration indicated a statistically significant improvement between the acrylic resin (99.6 mg/dL) and silicone soft reliner (126.0 mg/dL) obturator prosthesis (p = .043). There was no significant difference in the median of maximum bite force between the acrylic resin (302.0 N) and silicone soft reliner (250.0 N) obturator prosthesis (p = .893). Functional limitations domain of the OHIP‐J49 indicated a statistically significant improvement between the acrylic resin and silicone soft reliner obturator prosthesis (p = .043). CONCLUSIONS: This study indicated that an obturator relined with soft silicone improved masticatory performance and the OHRQoL post‐maxillectomy.
format Online
Article
Text
id pubmed-7745077
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-77450772020-12-18 Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single‐arm prospective interventional study Yanamoto, Souichi Soutome, Sakiko Murata, Maho Kawakita, Akiko Yamaguchi, Erika Yoshida, Kazuhiro Kurogi, Tadafumi Kuroshima, Shinichiro Murata, Hiroshi Sawase, Takashi Umeda, Masahiro Clin Exp Dent Res Original Articles BACKGROUND: There is insufficient evidence for the efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors. OBJECTIVE: To verify the efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy, by evaluating masticatory performance and quality of life (QoL). METHODS: This was a single‐arm prospective interventional study, verifying the efficacy of silicone soft reliner (GC RELINE II®) on the maxillary obturator prosthesis. Data were obtained from a comparison of the endpoints after 14 days of continuous use of acrylic and silicone soft‐lined prostheses. The primary endpoint was masticatory performance. The secondary endpoints were occlusal performance and oral health‐related QoL (OHRQoL). The masticatory performance, occlusal performance, and OHRQoL were assessed by glucose concentration, maximum bite force, and the Japanese version of Oral Health Impact Profile (OHIP‐J49), respectively. RESULTS: This study included five patients (two males, three females), aged between 71 and 88 years, with a median of 74 years. The median of glucose concentration indicated a statistically significant improvement between the acrylic resin (99.6 mg/dL) and silicone soft reliner (126.0 mg/dL) obturator prosthesis (p = .043). There was no significant difference in the median of maximum bite force between the acrylic resin (302.0 N) and silicone soft reliner (250.0 N) obturator prosthesis (p = .893). Functional limitations domain of the OHIP‐J49 indicated a statistically significant improvement between the acrylic resin and silicone soft reliner obturator prosthesis (p = .043). CONCLUSIONS: This study indicated that an obturator relined with soft silicone improved masticatory performance and the OHRQoL post‐maxillectomy. John Wiley and Sons Inc. 2020-09-08 /pmc/articles/PMC7745077/ /pubmed/32896981 http://dx.doi.org/10.1002/cre2.326 Text en © 2020 The Authors. Clinical and Experimental Dental Research published by John Wiley & Sons Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Yanamoto, Souichi
Soutome, Sakiko
Murata, Maho
Kawakita, Akiko
Yamaguchi, Erika
Yoshida, Kazuhiro
Kurogi, Tadafumi
Kuroshima, Shinichiro
Murata, Hiroshi
Sawase, Takashi
Umeda, Masahiro
Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single‐arm prospective interventional study
title Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single‐arm prospective interventional study
title_full Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single‐arm prospective interventional study
title_fullStr Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single‐arm prospective interventional study
title_full_unstemmed Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single‐arm prospective interventional study
title_short Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single‐arm prospective interventional study
title_sort efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: a single‐arm prospective interventional study
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7745077/
https://www.ncbi.nlm.nih.gov/pubmed/32896981
http://dx.doi.org/10.1002/cre2.326
work_keys_str_mv AT yanamotosouichi efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT soutomesakiko efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT muratamaho efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT kawakitaakiko efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT yamaguchierika efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT yoshidakazuhiro efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT kurogitadafumi efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT kuroshimashinichiro efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT muratahiroshi efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT sawasetakashi efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy
AT umedamasahiro efficacyofsiliconesoftrelinerontheobturatorprosthesisaftermaxillectomyfororalmalignanttumorsasinglearmprospectiveinterventionalstudy