Cargando…
Outcome of a single XEN microstent implant for glaucoma patients with different types of glaucoma
BACKGROUND: The aim of this retrospective study was to compare the efficacy and safety profile of a single XEN-microstent in different types of primary and secondary open angle glaucoma. METHODS: A single XEN microstent was implanted in patients with primary open-angle glaucoma (POAG), normal-tensio...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7745382/ https://www.ncbi.nlm.nih.gov/pubmed/33334311 http://dx.doi.org/10.1186/s12886-020-01764-8 |
Sumario: | BACKGROUND: The aim of this retrospective study was to compare the efficacy and safety profile of a single XEN-microstent in different types of primary and secondary open angle glaucoma. METHODS: A single XEN microstent was implanted in patients with primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG), pseudoexfoliation glaucoma (PEX) and secondary glaucoma (Sec.Gl). The intraocular pressure (IOP), the active substances of the applied IOP-lowering drugs, the best corrected visual acuity (BCVA) and the mean deviation (MD) of the perimetry were measured at baseline and at regular follow-ups, scheduled at 2 days and 1, 3, 6 and 12 months after surgery. RESULTS: 153 eyes were included in this analysis. 113 eyes were affected by POAG (74%), 5 eyes by NTG (3%), 22 eyes by PEX (14%) and 13 eyes by Sec. Gl (9%). Mean IOP decreased in all treatment groups during the 12 months of follow-up (complete group: 23.9 ± 7.4 to 15.4 ± 5.1 mmHg (p < 0.01); POAG: 22.8 ± 6.5 to 15.1 ± 4.6 mmHg (p < 0.01); NTG: 16.6 ± 3.4 to 11.6 ± 2.2 mmHg (p < 0.05); PEX: 28.0 ± 7.9 to 17.1 ± 6.6 mmHg (p < 0.01); Sec.Gl: 28.9 ± 13.9 to 15.5 ± 6.9 mmHg (p < 0.05)). In the 153 eyes the average number of IOP-lowering drugs applied decreased from 2.6 ± 1.2 to 0.8 ± 1.3 12 months after surgery (p < 0.01). BCVA and mean deviation of automated standard perimetry remained stable in all groups during follow-up. CONCLUSION: As in eyes suffering from POAG, IOP and number of IOP-lowering drugs applied can be effectively reduced by XEN implantation in eyes suffering from NTG, PEX and secondary glaucoma while leaving BCVA and visual field unchanged. TRIAL REGISTRATION: Trial was registered at DRKS (registration number: DRKS00020800, Registered 25.February 2020 - Retrospectively registered). |
---|