Cargando…
Diagnostic value of sentinel lymph node scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer
Cervical cancer is staged clinically using the International Federation of Gynaecology and Obstetrics staging system. Although lymph node status does not form part of the staging, it has important prognostic and potential therapeutic implications. The aim of the study was to evaluate the role of sen...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7745871/ https://www.ncbi.nlm.nih.gov/pubmed/33354179 http://dx.doi.org/10.4103/wjnm.WJNM_74_19 |
_version_ | 1783624689044684800 |
---|---|
author | Reyneke, Florette Snyman, Leon Cornelius Lawal, Ismaheel Lengana, Thabo Vorster, Mariza Sathekge, Mike |
author_facet | Reyneke, Florette Snyman, Leon Cornelius Lawal, Ismaheel Lengana, Thabo Vorster, Mariza Sathekge, Mike |
author_sort | Reyneke, Florette |
collection | PubMed |
description | Cervical cancer is staged clinically using the International Federation of Gynaecology and Obstetrics staging system. Although lymph node status does not form part of the staging, it has important prognostic and potential therapeutic implications. The aim of the study was to evaluate the role of sentinel lymph node (SLN) scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in detecting lymph node metastases in patients with early-stage cervical cancer. Thirty-six patients with early-stage cervical cancer underwent SLN detection during primary operation. Of the 36 patients, 28 patients underwent (18)F-FDG PET/CT before surgery. The (18)F-FDG PET/CT images were analyzed with the histopathological findings as the reference standard. The diagnostic performance of (18)F-FDG PET/CT in the detection of nodal disease was reported in terms of accuracy value. The SLN detection rate was the highest (91.7%) using the combined method (lymphoscintigraphy, intraoperative gamma probe, and blue dye). Seven of the thirty-six patients had lymph node involvement (19.4%), of which five had preoperative (18)F-FDG PET/CT imaging. On overall patient-based analysis, the sensitivity, specificity, positive predictive value, negative predictive value (NPV), and accuracy of (18)F-FDG PET/CT were 40.0%, 78.3%, 28.6%, 85.7%, and 71.4%, respectively. The combination of radiolabeled nanocolloid with blue dye is safe and reliable and allows successful detection of SLNs in patients with early-stage cervical cancer in a population with high prevalence of human immunodeficiency virus. The specificity and NPV of (18)F-FDG PET/CT are high and can be used in conjunction with SLN biopsy. |
format | Online Article Text |
id | pubmed-7745871 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-77458712020-12-21 Diagnostic value of sentinel lymph node scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer Reyneke, Florette Snyman, Leon Cornelius Lawal, Ismaheel Lengana, Thabo Vorster, Mariza Sathekge, Mike World J Nucl Med Original Article Cervical cancer is staged clinically using the International Federation of Gynaecology and Obstetrics staging system. Although lymph node status does not form part of the staging, it has important prognostic and potential therapeutic implications. The aim of the study was to evaluate the role of sentinel lymph node (SLN) scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in detecting lymph node metastases in patients with early-stage cervical cancer. Thirty-six patients with early-stage cervical cancer underwent SLN detection during primary operation. Of the 36 patients, 28 patients underwent (18)F-FDG PET/CT before surgery. The (18)F-FDG PET/CT images were analyzed with the histopathological findings as the reference standard. The diagnostic performance of (18)F-FDG PET/CT in the detection of nodal disease was reported in terms of accuracy value. The SLN detection rate was the highest (91.7%) using the combined method (lymphoscintigraphy, intraoperative gamma probe, and blue dye). Seven of the thirty-six patients had lymph node involvement (19.4%), of which five had preoperative (18)F-FDG PET/CT imaging. On overall patient-based analysis, the sensitivity, specificity, positive predictive value, negative predictive value (NPV), and accuracy of (18)F-FDG PET/CT were 40.0%, 78.3%, 28.6%, 85.7%, and 71.4%, respectively. The combination of radiolabeled nanocolloid with blue dye is safe and reliable and allows successful detection of SLNs in patients with early-stage cervical cancer in a population with high prevalence of human immunodeficiency virus. The specificity and NPV of (18)F-FDG PET/CT are high and can be used in conjunction with SLN biopsy. Wolters Kluwer - Medknow 2020-07-22 /pmc/articles/PMC7745871/ /pubmed/33354179 http://dx.doi.org/10.4103/wjnm.WJNM_74_19 Text en Copyright: © 2020 World Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Reyneke, Florette Snyman, Leon Cornelius Lawal, Ismaheel Lengana, Thabo Vorster, Mariza Sathekge, Mike Diagnostic value of sentinel lymph node scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer |
title | Diagnostic value of sentinel lymph node scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer |
title_full | Diagnostic value of sentinel lymph node scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer |
title_fullStr | Diagnostic value of sentinel lymph node scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer |
title_full_unstemmed | Diagnostic value of sentinel lymph node scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer |
title_short | Diagnostic value of sentinel lymph node scintigraphy and 2-[(18)F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer |
title_sort | diagnostic value of sentinel lymph node scintigraphy and 2-[(18)f]-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography in the detection of metastatic lymph nodes in patients with early-stage cervical cancer |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7745871/ https://www.ncbi.nlm.nih.gov/pubmed/33354179 http://dx.doi.org/10.4103/wjnm.WJNM_74_19 |
work_keys_str_mv | AT reynekeflorette diagnosticvalueofsentinellymphnodescintigraphyand218ffluoro2deoxydglucosepositronemissiontomographycomputedtomographyinthedetectionofmetastaticlymphnodesinpatientswithearlystagecervicalcancer AT snymanleoncornelius diagnosticvalueofsentinellymphnodescintigraphyand218ffluoro2deoxydglucosepositronemissiontomographycomputedtomographyinthedetectionofmetastaticlymphnodesinpatientswithearlystagecervicalcancer AT lawalismaheel diagnosticvalueofsentinellymphnodescintigraphyand218ffluoro2deoxydglucosepositronemissiontomographycomputedtomographyinthedetectionofmetastaticlymphnodesinpatientswithearlystagecervicalcancer AT lenganathabo diagnosticvalueofsentinellymphnodescintigraphyand218ffluoro2deoxydglucosepositronemissiontomographycomputedtomographyinthedetectionofmetastaticlymphnodesinpatientswithearlystagecervicalcancer AT vorstermariza diagnosticvalueofsentinellymphnodescintigraphyand218ffluoro2deoxydglucosepositronemissiontomographycomputedtomographyinthedetectionofmetastaticlymphnodesinpatientswithearlystagecervicalcancer AT sathekgemike diagnosticvalueofsentinellymphnodescintigraphyand218ffluoro2deoxydglucosepositronemissiontomographycomputedtomographyinthedetectionofmetastaticlymphnodesinpatientswithearlystagecervicalcancer |