Cargando…

Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump

Extracorporeal life support (ECLS) can result in complications due to increased left ventricular (LV) afterload. The percutaneous ventricular assist device (PVAD) and intra-aortic balloon pump (IABP) are both considered to be effective means of LV unloading. This study describes the efficacy of LV u...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakajima, Tomohiro, Tanaka, Yuki, Fischer, Irene, Kotkar, Kunal, Damiano, Ralph J., Moon, Marc R., Masood, Muhammad F., Itoh, Akinobu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7745888/
https://www.ncbi.nlm.nih.gov/pubmed/33346989
http://dx.doi.org/10.1097/MAT.0000000000001192
_version_ 1783624692592017408
author Nakajima, Tomohiro
Tanaka, Yuki
Fischer, Irene
Kotkar, Kunal
Damiano, Ralph J.
Moon, Marc R.
Masood, Muhammad F.
Itoh, Akinobu
author_facet Nakajima, Tomohiro
Tanaka, Yuki
Fischer, Irene
Kotkar, Kunal
Damiano, Ralph J.
Moon, Marc R.
Masood, Muhammad F.
Itoh, Akinobu
author_sort Nakajima, Tomohiro
collection PubMed
description Extracorporeal life support (ECLS) can result in complications due to increased left ventricular (LV) afterload. The percutaneous ventricular assist device (PVAD) and intra-aortic balloon pump (IABP) are both considered to be effective means of LV unloading. This study describes the efficacy of LV unloading and related outcomes with PVAD or IABP during ECLS. From January 2010 to April 2018, all cardiogenic shock patients who underwent ECLS plus simultaneous PVAD or IABP were analyzed. Forty-nine patients received ECLS + PVAD, while 91 received ECLS + IABP. At 48 hours, mean pulmonary artery pressure was significantly reduced in both groups [34 mm Hg to 22, p < 0.01; 32 mm Hg to 21, p < 0.01; ECLS + PVAD and ECLS + IABP group, respectively]. The two groups had similar 30 day survival rates [19 patients (39%) vs. 35 (39%), p = 0.56]. The ECLS + PVAD group had higher incidences of bleeding at the insertion site [11 (22%) vs. 0, p < 0.01] and major hemolysis [9 (18%) vs. 0, p < 0.01]. Both groups had improvement in LV end-diastolic dimension (61 ± 12 mm to 54 ± 12, p = 0.03; 60 ± 12 mm to 47 ± 10, p < 0.01), and LV ejection fraction (16 ± 7% to 22 ± 10, p < 0.01; 22 ± 12% to 29 ± 15, p = 0.01). Both ECLS + PVAD and ECLS + IABP effectively reduced pulmonary artery pressure and improved LV function. Bleeding at the PVAD or IABP insertion site occurred more frequently in the ECLS + PVAD group than the ECLS + IABP group (p < 0.01). Nine patients (18%) in the ECLS + PVAD group experienced major hemolysis, while there was no hemolysis in the ECLS + IABP group (p < 0.01). Careful considerations are required before selecting an additional support to ECLS.
format Online
Article
Text
id pubmed-7745888
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-77458882020-12-22 Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump Nakajima, Tomohiro Tanaka, Yuki Fischer, Irene Kotkar, Kunal Damiano, Ralph J. Moon, Marc R. Masood, Muhammad F. Itoh, Akinobu ASAIO J Adult Circulatory Support Extracorporeal life support (ECLS) can result in complications due to increased left ventricular (LV) afterload. The percutaneous ventricular assist device (PVAD) and intra-aortic balloon pump (IABP) are both considered to be effective means of LV unloading. This study describes the efficacy of LV unloading and related outcomes with PVAD or IABP during ECLS. From January 2010 to April 2018, all cardiogenic shock patients who underwent ECLS plus simultaneous PVAD or IABP were analyzed. Forty-nine patients received ECLS + PVAD, while 91 received ECLS + IABP. At 48 hours, mean pulmonary artery pressure was significantly reduced in both groups [34 mm Hg to 22, p < 0.01; 32 mm Hg to 21, p < 0.01; ECLS + PVAD and ECLS + IABP group, respectively]. The two groups had similar 30 day survival rates [19 patients (39%) vs. 35 (39%), p = 0.56]. The ECLS + PVAD group had higher incidences of bleeding at the insertion site [11 (22%) vs. 0, p < 0.01] and major hemolysis [9 (18%) vs. 0, p < 0.01]. Both groups had improvement in LV end-diastolic dimension (61 ± 12 mm to 54 ± 12, p = 0.03; 60 ± 12 mm to 47 ± 10, p < 0.01), and LV ejection fraction (16 ± 7% to 22 ± 10, p < 0.01; 22 ± 12% to 29 ± 15, p = 0.01). Both ECLS + PVAD and ECLS + IABP effectively reduced pulmonary artery pressure and improved LV function. Bleeding at the PVAD or IABP insertion site occurred more frequently in the ECLS + PVAD group than the ECLS + IABP group (p < 0.01). Nine patients (18%) in the ECLS + PVAD group experienced major hemolysis, while there was no hemolysis in the ECLS + IABP group (p < 0.01). Careful considerations are required before selecting an additional support to ECLS. Lippincott Williams & Wilkins 2020-06-03 2021-01 /pmc/articles/PMC7745888/ /pubmed/33346989 http://dx.doi.org/10.1097/MAT.0000000000001192 Text en Copyright © ASAIO 2020 This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Adult Circulatory Support
Nakajima, Tomohiro
Tanaka, Yuki
Fischer, Irene
Kotkar, Kunal
Damiano, Ralph J.
Moon, Marc R.
Masood, Muhammad F.
Itoh, Akinobu
Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump
title Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump
title_full Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump
title_fullStr Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump
title_full_unstemmed Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump
title_short Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump
title_sort extracorporeal life support for cardiogenic shock with either a percutaneous ventricular assist device or an intra-aortic balloon pump
topic Adult Circulatory Support
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7745888/
https://www.ncbi.nlm.nih.gov/pubmed/33346989
http://dx.doi.org/10.1097/MAT.0000000000001192
work_keys_str_mv AT nakajimatomohiro extracorporeallifesupportforcardiogenicshockwitheitherapercutaneousventricularassistdeviceoranintraaorticballoonpump
AT tanakayuki extracorporeallifesupportforcardiogenicshockwitheitherapercutaneousventricularassistdeviceoranintraaorticballoonpump
AT fischerirene extracorporeallifesupportforcardiogenicshockwitheitherapercutaneousventricularassistdeviceoranintraaorticballoonpump
AT kotkarkunal extracorporeallifesupportforcardiogenicshockwitheitherapercutaneousventricularassistdeviceoranintraaorticballoonpump
AT damianoralphj extracorporeallifesupportforcardiogenicshockwitheitherapercutaneousventricularassistdeviceoranintraaorticballoonpump
AT moonmarcr extracorporeallifesupportforcardiogenicshockwitheitherapercutaneousventricularassistdeviceoranintraaorticballoonpump
AT masoodmuhammadf extracorporeallifesupportforcardiogenicshockwitheitherapercutaneousventricularassistdeviceoranintraaorticballoonpump
AT itohakinobu extracorporeallifesupportforcardiogenicshockwitheitherapercutaneousventricularassistdeviceoranintraaorticballoonpump