Effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography

We assessed the inter-visit repeatability of 15 × 9-mm(2) swept-source OCTA (SS-OCTA; PLEX Elite 9000, Carl Zeiss Meditec) metrics in 14 healthy participants. We analysed the perfusion density (PD) of large vessels, superficial capillary plexus (SCP), and deep capillary plexus (DCP) as well as chori...

Descripción completa

Detalles Bibliográficos
Autores principales: Hong, Jimmy, Ke, Mengyuan, Tan, Bingyao, Lau, Amanda, Wong, Damon, Yao, Xinwen, Liu, Xinyu, Schmetterer, Leopold, Chua, Jacqueline
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7746686/
https://www.ncbi.nlm.nih.gov/pubmed/33335182
http://dx.doi.org/10.1038/s41598-020-79281-3
_version_ 1783624841368174592
author Hong, Jimmy
Ke, Mengyuan
Tan, Bingyao
Lau, Amanda
Wong, Damon
Yao, Xinwen
Liu, Xinyu
Schmetterer, Leopold
Chua, Jacqueline
author_facet Hong, Jimmy
Ke, Mengyuan
Tan, Bingyao
Lau, Amanda
Wong, Damon
Yao, Xinwen
Liu, Xinyu
Schmetterer, Leopold
Chua, Jacqueline
author_sort Hong, Jimmy
collection PubMed
description We assessed the inter-visit repeatability of 15 × 9-mm(2) swept-source OCTA (SS-OCTA; PLEX Elite 9000, Carl Zeiss Meditec) metrics in 14 healthy participants. We analysed the perfusion density (PD) of large vessels, superficial capillary plexus (SCP), and deep capillary plexus (DCP) as well as choriocapillaris flow voids in 2 different regions: the macular region and peripheral region. Also, retinal plexus metrics were processed further using different filters (Hessian, Gabor and Bayesian) while choriocapillaris flow voids were calculated with 1 and 1.25 standard deviation (SD) thresholding algorithms. We found excellent repeatability in the perfusion densities of large vessels (ICC > 0.96). Perfusion densities varied with different filters in the macular region (SCP: 24.12–38.57% and DCP: 25.16–38.50%) and peripheral (SCP: 30.52–39.84% and DCP: 34.19–41.60%) regions. The ICCs were lower in the macular region compared to the peripheral region and lower for DCP than for SCP. For choriocapillaris flow voids, the 1.25 SD threshold resulted in fewer flow voids, while a good ICC (ICC > 0.81) was achieved using either threshold settings for flow void features in both regions. Our results suggest good repeatability of widefield SS-OCTA for the measurements of retinal perfusion density and choriocapillaris flow voids, but measurements from different filters should not be interchanged.
format Online
Article
Text
id pubmed-7746686
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-77466862020-12-18 Effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography Hong, Jimmy Ke, Mengyuan Tan, Bingyao Lau, Amanda Wong, Damon Yao, Xinwen Liu, Xinyu Schmetterer, Leopold Chua, Jacqueline Sci Rep Article We assessed the inter-visit repeatability of 15 × 9-mm(2) swept-source OCTA (SS-OCTA; PLEX Elite 9000, Carl Zeiss Meditec) metrics in 14 healthy participants. We analysed the perfusion density (PD) of large vessels, superficial capillary plexus (SCP), and deep capillary plexus (DCP) as well as choriocapillaris flow voids in 2 different regions: the macular region and peripheral region. Also, retinal plexus metrics were processed further using different filters (Hessian, Gabor and Bayesian) while choriocapillaris flow voids were calculated with 1 and 1.25 standard deviation (SD) thresholding algorithms. We found excellent repeatability in the perfusion densities of large vessels (ICC > 0.96). Perfusion densities varied with different filters in the macular region (SCP: 24.12–38.57% and DCP: 25.16–38.50%) and peripheral (SCP: 30.52–39.84% and DCP: 34.19–41.60%) regions. The ICCs were lower in the macular region compared to the peripheral region and lower for DCP than for SCP. For choriocapillaris flow voids, the 1.25 SD threshold resulted in fewer flow voids, while a good ICC (ICC > 0.81) was achieved using either threshold settings for flow void features in both regions. Our results suggest good repeatability of widefield SS-OCTA for the measurements of retinal perfusion density and choriocapillaris flow voids, but measurements from different filters should not be interchanged. Nature Publishing Group UK 2020-12-17 /pmc/articles/PMC7746686/ /pubmed/33335182 http://dx.doi.org/10.1038/s41598-020-79281-3 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Hong, Jimmy
Ke, Mengyuan
Tan, Bingyao
Lau, Amanda
Wong, Damon
Yao, Xinwen
Liu, Xinyu
Schmetterer, Leopold
Chua, Jacqueline
Effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography
title Effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography
title_full Effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography
title_fullStr Effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography
title_full_unstemmed Effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography
title_short Effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography
title_sort effect of vessel enhancement filters on the repeatability of measurements obtained from widefield swept-source optical coherence tomography angiography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7746686/
https://www.ncbi.nlm.nih.gov/pubmed/33335182
http://dx.doi.org/10.1038/s41598-020-79281-3
work_keys_str_mv AT hongjimmy effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography
AT kemengyuan effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography
AT tanbingyao effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography
AT lauamanda effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography
AT wongdamon effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography
AT yaoxinwen effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography
AT liuxinyu effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography
AT schmettererleopold effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography
AT chuajacqueline effectofvesselenhancementfiltersontherepeatabilityofmeasurementsobtainedfromwidefieldsweptsourceopticalcoherencetomographyangiography