Cargando…

Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic

BACKGROUND: We recently introduced the Barricor (BD, Franklin Lakes, NJ, USA) plasma separation tube, which uses a mechanical separator instead of a gel. We evaluated the effects of using the Barricor tube in a stat (statin) laboratory on the results and turnaround time (TAT) of routine chemical tes...

Descripción completa

Detalles Bibliográficos
Autores principales: Moon, Soo Young, Lee, Han Sol, Park, Min Soon, Kim, In-Suk, Lee, Sun Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society for Laboratory Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7748094/
https://www.ncbi.nlm.nih.gov/pubmed/33303712
http://dx.doi.org/10.3343/alm.2021.41.3.277
_version_ 1783625049004048384
author Moon, Soo Young
Lee, Han Sol
Park, Min Soon
Kim, In-Suk
Lee, Sun Min
author_facet Moon, Soo Young
Lee, Han Sol
Park, Min Soon
Kim, In-Suk
Lee, Sun Min
author_sort Moon, Soo Young
collection PubMed
description BACKGROUND: We recently introduced the Barricor (BD, Franklin Lakes, NJ, USA) plasma separation tube, which uses a mechanical separator instead of a gel. We evaluated the effects of using the Barricor tube in a stat (statin) laboratory on the results and turnaround time (TAT) of routine chemical tests. We verified the impact of Barricor tube on reducing TAT and providing results similar to those obtained using serum separator tubes (SSTs). METHODS: We collected venous blood samples from 166 outpatients in Barricor tubes and SSTs and measured 28 routine analytes using an AU5800 instrument (Beckman Coulter, Brea, CA, USA). TAT indexes were compared before and after using Barricor tube. RESULTS: Mean percent differences were <5%, except for alanine aminotransferase , total CO(2), high-density lipoprotein, phosphate, total protein, and direct bilirubin. The median TAT decreased from 45 to 38 minutes, and the rate of a TAT >60 minutes decreased from 7.84% to 2.66%, which was approximately one-third of that for SST. The reduction in TAT was attributable to a decrease in centrifugation time. Incomplete clotting and repeated centrifugation, which occurred frequently when using SST, also decreased after using the Barricor tubes. CONCLUSIONS: The Barricor tube is an alternative to SST for routine chemical tests in institutions aiming to reduce TAT, with clinically allowable differences in test results.
format Online
Article
Text
id pubmed-7748094
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-77480942021-05-01 Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic Moon, Soo Young Lee, Han Sol Park, Min Soon Kim, In-Suk Lee, Sun Min Ann Lab Med Original Article BACKGROUND: We recently introduced the Barricor (BD, Franklin Lakes, NJ, USA) plasma separation tube, which uses a mechanical separator instead of a gel. We evaluated the effects of using the Barricor tube in a stat (statin) laboratory on the results and turnaround time (TAT) of routine chemical tests. We verified the impact of Barricor tube on reducing TAT and providing results similar to those obtained using serum separator tubes (SSTs). METHODS: We collected venous blood samples from 166 outpatients in Barricor tubes and SSTs and measured 28 routine analytes using an AU5800 instrument (Beckman Coulter, Brea, CA, USA). TAT indexes were compared before and after using Barricor tube. RESULTS: Mean percent differences were <5%, except for alanine aminotransferase , total CO(2), high-density lipoprotein, phosphate, total protein, and direct bilirubin. The median TAT decreased from 45 to 38 minutes, and the rate of a TAT >60 minutes decreased from 7.84% to 2.66%, which was approximately one-third of that for SST. The reduction in TAT was attributable to a decrease in centrifugation time. Incomplete clotting and repeated centrifugation, which occurred frequently when using SST, also decreased after using the Barricor tubes. CONCLUSIONS: The Barricor tube is an alternative to SST for routine chemical tests in institutions aiming to reduce TAT, with clinically allowable differences in test results. Korean Society for Laboratory Medicine 2021-05-01 2021-05-01 /pmc/articles/PMC7748094/ /pubmed/33303712 http://dx.doi.org/10.3343/alm.2021.41.3.277 Text en © Korean Society for Laboratory Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Moon, Soo Young
Lee, Han Sol
Park, Min Soon
Kim, In-Suk
Lee, Sun Min
Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic
title Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic
title_full Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic
title_fullStr Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic
title_full_unstemmed Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic
title_short Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic
title_sort evaluation of the barricor tube in 28 routine chemical tests and its impact on turnaround time in an outpatient clinic
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7748094/
https://www.ncbi.nlm.nih.gov/pubmed/33303712
http://dx.doi.org/10.3343/alm.2021.41.3.277
work_keys_str_mv AT moonsooyoung evaluationofthebarricortubein28routinechemicaltestsanditsimpactonturnaroundtimeinanoutpatientclinic
AT leehansol evaluationofthebarricortubein28routinechemicaltestsanditsimpactonturnaroundtimeinanoutpatientclinic
AT parkminsoon evaluationofthebarricortubein28routinechemicaltestsanditsimpactonturnaroundtimeinanoutpatientclinic
AT kiminsuk evaluationofthebarricortubein28routinechemicaltestsanditsimpactonturnaroundtimeinanoutpatientclinic
AT leesunmin evaluationofthebarricortubein28routinechemicaltestsanditsimpactonturnaroundtimeinanoutpatientclinic