Cargando…
Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic
BACKGROUND: We recently introduced the Barricor (BD, Franklin Lakes, NJ, USA) plasma separation tube, which uses a mechanical separator instead of a gel. We evaluated the effects of using the Barricor tube in a stat (statin) laboratory on the results and turnaround time (TAT) of routine chemical tes...
Autores principales: | Moon, Soo Young, Lee, Han Sol, Park, Min Soon, Kim, In-Suk, Lee, Sun Min |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society for Laboratory Medicine
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7748094/ https://www.ncbi.nlm.nih.gov/pubmed/33303712 http://dx.doi.org/10.3343/alm.2021.41.3.277 |
Ejemplares similares
-
Switching from serum to plasma: Implementation of BD Vacutainer® Barricor™ Plasma Blood Collection Tubes improves sample quality and laboratory turnaround time
por: Ramakers, Christian, et al.
Publicado: (2019) -
Improved quality of samples and laboratory turnaround time using 3.5 mL low vacuum BD Vacutainer(®) Barricor tubes in the emergency department
por: Badiou, S., et al.
Publicado: (2019) -
Strategies to shorten turnaround time in outpatient laboratory
por: Lee, Seunghoo, et al.
Publicado: (2022) -
Comparison of Barricor™ vs. lithium heparin tubes for selected routine biochemical analytes and evaluation of post centrifugation stability
por: Dupuy, Anne Marie, et al.
Publicado: (2018) -
Test results comparison and sample stability study: is the BD Barricor tube a suitable replacement for the BD RST tube?
por: Mandić, Sanja, et al.
Publicado: (2020)