Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism
BACKGROUND: Use of real-time continuous glucose monitoring (rtCGM) systems has been shown to be a low-pain, safe, and effective method of preventing hypoglycemia and hyperglycemia in people with diabetes of various age groups. Evidence on rtCGM use in infants and in patients with conditions other th...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7748959/ https://www.ncbi.nlm.nih.gov/pubmed/33275114 http://dx.doi.org/10.2196/21770 |
_version_ | 1783625231611461632 |
---|---|
author | Braune, Katarina Wäldchen, Mandy Raile, Klemens Hahn, Sigrid Ubben, Tebbe Römer, Susanne Hoeber, Daniela Reibel, Nora Johanna Launspach, Michael Blankenstein, Oliver Bührer, Christoph |
author_facet | Braune, Katarina Wäldchen, Mandy Raile, Klemens Hahn, Sigrid Ubben, Tebbe Römer, Susanne Hoeber, Daniela Reibel, Nora Johanna Launspach, Michael Blankenstein, Oliver Bührer, Christoph |
author_sort | Braune, Katarina |
collection | PubMed |
description | BACKGROUND: Use of real-time continuous glucose monitoring (rtCGM) systems has been shown to be a low-pain, safe, and effective method of preventing hypoglycemia and hyperglycemia in people with diabetes of various age groups. Evidence on rtCGM use in infants and in patients with conditions other than diabetes remains limited. OBJECTIVE: This case study describes the off-label use of rtCGM and the use of an open-source app for glucose monitoring in a newborn with prolonged hypoglycemia secondary to transient congenital hyperinsulinism during the perinatal period. METHODS: The Dexcom G6 rtCGM system (Dexcom, Inc) was introduced at 39 hours of age. Capillary blood glucose checks were performed regularly. In order to benefit from customizable alert settings and detect hypoglycemic episodes, the open-source rtCGM app xDrip+ was introduced at 9 days of age. RESULTS: Time in range (45-180 mg/dL) for interstitial glucose remained consistently above 90%, whereas time in hypoglycemia (<45 mg/dL) decreased. Mean glucose was maintained above 70 mg/dL at 72 hours of life and thereafter. Daily sensor glucose profiles showed cyclic fluctuations that were less pronounced over time. CONCLUSIONS: While off-label use of medication is both common practice and a necessity in newborn infants, there are few examples of off-label uses of medical devices, rtCGM being a notable exception. Real-time information allowed us to better understand glycemic patterns and to improve the quality of glycemic control accordingly. Severe hypoglycemia was prevented, and measurement of serum levels of insulin and further lab diagnostics were performed much faster, while the patient’s individual burden caused by invasive procedures was reduced. Greater customizability of threshold and alert settings would be beneficial for user groups with glycemic instability other than people with diabetes, and for hospitalized newborn infants in particular. Further research in the field of personal and off-label rtCGM use, efficacy studies evaluating the accuracy of low glucose readings, and studies on the differences between algorithms in translating raw sensor data, as well as customization of commercially available rtCGM systems, is needed. |
format | Online Article Text |
id | pubmed-7748959 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-77489592020-12-30 Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism Braune, Katarina Wäldchen, Mandy Raile, Klemens Hahn, Sigrid Ubben, Tebbe Römer, Susanne Hoeber, Daniela Reibel, Nora Johanna Launspach, Michael Blankenstein, Oliver Bührer, Christoph J Med Internet Res Original Paper BACKGROUND: Use of real-time continuous glucose monitoring (rtCGM) systems has been shown to be a low-pain, safe, and effective method of preventing hypoglycemia and hyperglycemia in people with diabetes of various age groups. Evidence on rtCGM use in infants and in patients with conditions other than diabetes remains limited. OBJECTIVE: This case study describes the off-label use of rtCGM and the use of an open-source app for glucose monitoring in a newborn with prolonged hypoglycemia secondary to transient congenital hyperinsulinism during the perinatal period. METHODS: The Dexcom G6 rtCGM system (Dexcom, Inc) was introduced at 39 hours of age. Capillary blood glucose checks were performed regularly. In order to benefit from customizable alert settings and detect hypoglycemic episodes, the open-source rtCGM app xDrip+ was introduced at 9 days of age. RESULTS: Time in range (45-180 mg/dL) for interstitial glucose remained consistently above 90%, whereas time in hypoglycemia (<45 mg/dL) decreased. Mean glucose was maintained above 70 mg/dL at 72 hours of life and thereafter. Daily sensor glucose profiles showed cyclic fluctuations that were less pronounced over time. CONCLUSIONS: While off-label use of medication is both common practice and a necessity in newborn infants, there are few examples of off-label uses of medical devices, rtCGM being a notable exception. Real-time information allowed us to better understand glycemic patterns and to improve the quality of glycemic control accordingly. Severe hypoglycemia was prevented, and measurement of serum levels of insulin and further lab diagnostics were performed much faster, while the patient’s individual burden caused by invasive procedures was reduced. Greater customizability of threshold and alert settings would be beneficial for user groups with glycemic instability other than people with diabetes, and for hospitalized newborn infants in particular. Further research in the field of personal and off-label rtCGM use, efficacy studies evaluating the accuracy of low glucose readings, and studies on the differences between algorithms in translating raw sensor data, as well as customization of commercially available rtCGM systems, is needed. JMIR Publications 2020-12-04 /pmc/articles/PMC7748959/ /pubmed/33275114 http://dx.doi.org/10.2196/21770 Text en ©Katarina Braune, Mandy Wäldchen, Klemens Raile, Sigrid Hahn, Tebbe Ubben, Susanne Römer, Daniela Hoeber, Nora Johanna Reibel, Michael Launspach, Oliver Blankenstein, Christoph Bührer. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 04.12.2020. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on http://www.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Braune, Katarina Wäldchen, Mandy Raile, Klemens Hahn, Sigrid Ubben, Tebbe Römer, Susanne Hoeber, Daniela Reibel, Nora Johanna Launspach, Michael Blankenstein, Oliver Bührer, Christoph Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism |
title | Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism |
title_full | Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism |
title_fullStr | Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism |
title_full_unstemmed | Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism |
title_short | Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism |
title_sort | open-source technology for real-time continuous glucose monitoring in the neonatal intensive care unit: case study in a neonate with transient congenital hyperinsulinism |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7748959/ https://www.ncbi.nlm.nih.gov/pubmed/33275114 http://dx.doi.org/10.2196/21770 |
work_keys_str_mv | AT braunekatarina opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT waldchenmandy opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT raileklemens opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT hahnsigrid opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT ubbentebbe opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT romersusanne opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT hoeberdaniela opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT reibelnorajohanna opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT launspachmichael opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT blankensteinoliver opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism AT buhrerchristoph opensourcetechnologyforrealtimecontinuousglucosemonitoringintheneonatalintensivecareunitcasestudyinaneonatewithtransientcongenitalhyperinsulinism |