Cargando…
The Impact of Hypothermic Pulsatile Machine Perfusion Versus Static Cold Storage: A Donor-Matched Paired Analysis in a Scenario of High Incidence of Delayed Kidney Graft Function
BACKGROUND: The present study analyzed the impact of hypothermic pulsatile machine perfusion (MP) following a long period of static cold (SC) storage in the peculiar Brazilian scenario of high incidence of delayed graft function (DGF), despite good donor characteristics. MATERIAL/METHODS: A retrospe...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7749524/ https://www.ncbi.nlm.nih.gov/pubmed/33318465 http://dx.doi.org/10.12659/AOT.927010 |
_version_ | 1783625319952941056 |
---|---|
author | de Sandes-Freitas, Tainá Veras Costa, Silvana Daher de Andrade, Luís Gustavo Modelli Girão, Celi Melo Fernandes, Paula Frassinetti C.B.C. de Oliveira, Claudia Maria Costa de Matos Esmeraldo, Ronaldo |
author_facet | de Sandes-Freitas, Tainá Veras Costa, Silvana Daher de Andrade, Luís Gustavo Modelli Girão, Celi Melo Fernandes, Paula Frassinetti C.B.C. de Oliveira, Claudia Maria Costa de Matos Esmeraldo, Ronaldo |
author_sort | de Sandes-Freitas, Tainá Veras |
collection | PubMed |
description | BACKGROUND: The present study analyzed the impact of hypothermic pulsatile machine perfusion (MP) following a long period of static cold (SC) storage in the peculiar Brazilian scenario of high incidence of delayed graft function (DGF), despite good donor characteristics. MATERIAL/METHODS: A retrospective analysis, with a 1-year follow-up, of 206 recipients of donor-matched paired kidneys was performed. Of the 206 donor kidneys, 103 were maintained exclusively in static cold storage (SC group) and 103 were kept on machine perfusion after a period of SC preservation (MP group). All donors were brain dead. RESULTS: Only 4.9% of the kidneys were from expanded-criteria donors. Static cold ischemia time (CIT) in the SC group was 20.8±4.1 hours vs. 15.8±6.2 hours in the MP group (P<0.001). Dynamic CIT in the MP group was 12.3±5.7 hours. MP significantly reduced DGF incidence (29.1% vs. 55.3%, P<0.001), and this effect was confirmed in multivariable analysis (OR, 1.115; 95% CI, 1.033–1.204, P=0.001). No differences were observed between the groups with regard to DGF duration, length of hospital stay, incidence of primary nonfunction and acute rejection, graft loss, death, or renal function. CONCLUSIONS: In this Brazilian setting, MP following a long period of SC preservation was associated with reduced DGF incidence in comparison with SC storage without MP. |
format | Online Article Text |
id | pubmed-7749524 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77495242020-12-30 The Impact of Hypothermic Pulsatile Machine Perfusion Versus Static Cold Storage: A Donor-Matched Paired Analysis in a Scenario of High Incidence of Delayed Kidney Graft Function de Sandes-Freitas, Tainá Veras Costa, Silvana Daher de Andrade, Luís Gustavo Modelli Girão, Celi Melo Fernandes, Paula Frassinetti C.B.C. de Oliveira, Claudia Maria Costa de Matos Esmeraldo, Ronaldo Ann Transplant Original Paper BACKGROUND: The present study analyzed the impact of hypothermic pulsatile machine perfusion (MP) following a long period of static cold (SC) storage in the peculiar Brazilian scenario of high incidence of delayed graft function (DGF), despite good donor characteristics. MATERIAL/METHODS: A retrospective analysis, with a 1-year follow-up, of 206 recipients of donor-matched paired kidneys was performed. Of the 206 donor kidneys, 103 were maintained exclusively in static cold storage (SC group) and 103 were kept on machine perfusion after a period of SC preservation (MP group). All donors were brain dead. RESULTS: Only 4.9% of the kidneys were from expanded-criteria donors. Static cold ischemia time (CIT) in the SC group was 20.8±4.1 hours vs. 15.8±6.2 hours in the MP group (P<0.001). Dynamic CIT in the MP group was 12.3±5.7 hours. MP significantly reduced DGF incidence (29.1% vs. 55.3%, P<0.001), and this effect was confirmed in multivariable analysis (OR, 1.115; 95% CI, 1.033–1.204, P=0.001). No differences were observed between the groups with regard to DGF duration, length of hospital stay, incidence of primary nonfunction and acute rejection, graft loss, death, or renal function. CONCLUSIONS: In this Brazilian setting, MP following a long period of SC preservation was associated with reduced DGF incidence in comparison with SC storage without MP. International Scientific Literature, Inc. 2020-12-15 /pmc/articles/PMC7749524/ /pubmed/33318465 http://dx.doi.org/10.12659/AOT.927010 Text en © Ann Transplant, 2020 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Original Paper de Sandes-Freitas, Tainá Veras Costa, Silvana Daher de Andrade, Luís Gustavo Modelli Girão, Celi Melo Fernandes, Paula Frassinetti C.B.C. de Oliveira, Claudia Maria Costa de Matos Esmeraldo, Ronaldo The Impact of Hypothermic Pulsatile Machine Perfusion Versus Static Cold Storage: A Donor-Matched Paired Analysis in a Scenario of High Incidence of Delayed Kidney Graft Function |
title | The Impact of Hypothermic Pulsatile Machine Perfusion Versus Static Cold Storage: A Donor-Matched Paired Analysis in a Scenario of High Incidence of Delayed Kidney Graft Function |
title_full | The Impact of Hypothermic Pulsatile Machine Perfusion Versus Static Cold Storage: A Donor-Matched Paired Analysis in a Scenario of High Incidence of Delayed Kidney Graft Function |
title_fullStr | The Impact of Hypothermic Pulsatile Machine Perfusion Versus Static Cold Storage: A Donor-Matched Paired Analysis in a Scenario of High Incidence of Delayed Kidney Graft Function |
title_full_unstemmed | The Impact of Hypothermic Pulsatile Machine Perfusion Versus Static Cold Storage: A Donor-Matched Paired Analysis in a Scenario of High Incidence of Delayed Kidney Graft Function |
title_short | The Impact of Hypothermic Pulsatile Machine Perfusion Versus Static Cold Storage: A Donor-Matched Paired Analysis in a Scenario of High Incidence of Delayed Kidney Graft Function |
title_sort | impact of hypothermic pulsatile machine perfusion versus static cold storage: a donor-matched paired analysis in a scenario of high incidence of delayed kidney graft function |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7749524/ https://www.ncbi.nlm.nih.gov/pubmed/33318465 http://dx.doi.org/10.12659/AOT.927010 |
work_keys_str_mv | AT desandesfreitastainaveras theimpactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT costasilvanadaher theimpactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT deandradeluisgustavomodelli theimpactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT giraocelimelo theimpactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT fernandespaulafrassinetticbc theimpactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT deoliveiraclaudiamariacosta theimpactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT dematosesmeraldoronaldo theimpactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT desandesfreitastainaveras impactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT costasilvanadaher impactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT deandradeluisgustavomodelli impactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT giraocelimelo impactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT fernandespaulafrassinetticbc impactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT deoliveiraclaudiamariacosta impactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction AT dematosesmeraldoronaldo impactofhypothermicpulsatilemachineperfusionversusstaticcoldstorageadonormatchedpairedanalysisinascenarioofhighincidenceofdelayedkidneygraftfunction |