Cargando…

Effective dose in medicine

The International Commission on Radiological Protection (ICRP) developed effective dose as a quantity related to risk for occupational and public exposure. There was a need for a similar dose quantity linked to risk for making everyday decisions relating to medical procedures. Coefficients were deve...

Descripción completa

Detalles Bibliográficos
Autor principal: Martin, C.J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7750662/
https://www.ncbi.nlm.nih.gov/pubmed/33147998
http://dx.doi.org/10.1177/0146645320927849
_version_ 1783625524056162304
author Martin, C.J.
author_facet Martin, C.J.
author_sort Martin, C.J.
collection PubMed
description The International Commission on Radiological Protection (ICRP) developed effective dose as a quantity related to risk for occupational and public exposure. There was a need for a similar dose quantity linked to risk for making everyday decisions relating to medical procedures. Coefficients were developed to enable the calculation of doses to organs and tissues, and effective doses for procedures in nuclear medicine and radiology during the 1980s and 1990s. Effective dose has provided a valuable tool that is now used in the establishment of guidelines for patient referral and justification of procedures, choice of appropriate imaging techniques, and providing dose data on potential exposure of volunteers for research studies, all of which require the benefits from the procedure to be weighed against the risks. However, the approximations made in the derivation of effective dose are often forgotten, and the uncertainties in calculations of risks are discussed. An ICRP report on protection dose quantities has been prepared that provides more information on the application of effective dose, and concludes that effective dose can be used as an approximate measure of possible risk. A discussion of the way in which it should be used is given here, with applications for which it is considered suitable. Approaches to the evaluation of risk and methods for conveying information on risk are also discussed.
format Online
Article
Text
id pubmed-7750662
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-77506622021-01-08 Effective dose in medicine Martin, C.J. Ann ICRP Medicine: Radiological Protection Challenges in Cutting-Edge Medicine The International Commission on Radiological Protection (ICRP) developed effective dose as a quantity related to risk for occupational and public exposure. There was a need for a similar dose quantity linked to risk for making everyday decisions relating to medical procedures. Coefficients were developed to enable the calculation of doses to organs and tissues, and effective doses for procedures in nuclear medicine and radiology during the 1980s and 1990s. Effective dose has provided a valuable tool that is now used in the establishment of guidelines for patient referral and justification of procedures, choice of appropriate imaging techniques, and providing dose data on potential exposure of volunteers for research studies, all of which require the benefits from the procedure to be weighed against the risks. However, the approximations made in the derivation of effective dose are often forgotten, and the uncertainties in calculations of risks are discussed. An ICRP report on protection dose quantities has been prepared that provides more information on the application of effective dose, and concludes that effective dose can be used as an approximate measure of possible risk. A discussion of the way in which it should be used is given here, with applications for which it is considered suitable. Approaches to the evaluation of risk and methods for conveying information on risk are also discussed. SAGE Publications 2020-11-04 2020-12 /pmc/articles/PMC7750662/ /pubmed/33147998 http://dx.doi.org/10.1177/0146645320927849 Text en © International Commission of Radiological Protection https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Medicine: Radiological Protection Challenges in Cutting-Edge Medicine
Martin, C.J.
Effective dose in medicine
title Effective dose in medicine
title_full Effective dose in medicine
title_fullStr Effective dose in medicine
title_full_unstemmed Effective dose in medicine
title_short Effective dose in medicine
title_sort effective dose in medicine
topic Medicine: Radiological Protection Challenges in Cutting-Edge Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7750662/
https://www.ncbi.nlm.nih.gov/pubmed/33147998
http://dx.doi.org/10.1177/0146645320927849
work_keys_str_mv AT martincj effectivedoseinmedicine