Cargando…

Mammographic sensitivity as a function of tumor size: A novel estimation based on population-based screening data

BACKGROUND: Instead of a single value for mammographic sensitivity, a sensitivity function based on tumor size more realistically reflects mammography’s detection capability. Because previous models may have overestimated size-specific sensitivity, we aimed to provide a novel approach to improve sen...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jing, Gottschal, Pam, Ding, Lilu, Veldhuizen, DaniëlleW.A van, Lu, Wenli, Houssami, Nehmat, Greuter, Marcel J.W., de Bock, Geertruida H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7753195/
https://www.ncbi.nlm.nih.gov/pubmed/33348148
http://dx.doi.org/10.1016/j.breast.2020.12.003
Descripción
Sumario:BACKGROUND: Instead of a single value for mammographic sensitivity, a sensitivity function based on tumor size more realistically reflects mammography’s detection capability. Because previous models may have overestimated size-specific sensitivity, we aimed to provide a novel approach to improve sensitivity estimation as a function of tumor size. METHODS: Using aggregated data on interval and screen-detected cancers, observed tumor sizes were back-calculated to the time of screening using an exponential tumor growth model and a follow-up time of 4 years. From the observed number of detected cancers and an estimation of the number of false-negative cancers, a model for the sensitivity as a function of tumor size was determined. A univariate sensitivity analysis was conducted by varying follow-up time and tumor volume doubling time (TVDT). A systematic review was conducted for external validation of the sensitivity model. RESULTS: Aggregated data of 22,915 screen-detected and 10,670 interval breast cancers from the Dutch screening program were used. The model showed that sensitivity increased from 0 to 85% for tumor sizes from 2 to 20 mm. When TVDT was set at the upper and lower limits of the confidence interval, sensitivity for a 20-mm tumor was 74% and 93%, respectively. The estimated sensitivity gave comparable estimates to those from two of three studies identified by our systematic review. CONCLUSION: Derived from aggregated breast screening outcomes data, our model’s estimation of sensitivity as a function of tumor size may provide a better representation of data observed in screening programs than other models.