Cargando…

Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report

Stent-graft placement is an important treatment for traumatic renal artery dissection, but it may occasionally be technically difficult to advance a catheter through the lesion of the dissection due to severe stenosis of the true rumen. A triple-coaxial (triaxial) system, which consists of a small m...

Descripción completa

Detalles Bibliográficos
Autores principales: Okabe, Haruka, Suzuki, Kazushi, Tsukahara, Satoshi, Kagaya, Risa, Kitase, Masanori, Mizutani, Masaru, Shimohira, Masashi, Shibamoto, Yuta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7753229/
https://www.ncbi.nlm.nih.gov/pubmed/33363689
http://dx.doi.org/10.1016/j.radcr.2020.12.032
_version_ 1783626029112229888
author Okabe, Haruka
Suzuki, Kazushi
Tsukahara, Satoshi
Kagaya, Risa
Kitase, Masanori
Mizutani, Masaru
Shimohira, Masashi
Shibamoto, Yuta
author_facet Okabe, Haruka
Suzuki, Kazushi
Tsukahara, Satoshi
Kagaya, Risa
Kitase, Masanori
Mizutani, Masaru
Shimohira, Masashi
Shibamoto, Yuta
author_sort Okabe, Haruka
collection PubMed
description Stent-graft placement is an important treatment for traumatic renal artery dissection, but it may occasionally be technically difficult to advance a catheter through the lesion of the dissection due to severe stenosis of the true rumen. A triple-coaxial (triaxial) system, which consists of a small microcatheter, a large microcatheter, and a 4-Fr. catheter, has recently become available, and it contributes to super-selective catheterization. We thought this system may be useful for passing catheters through the dissection. We herein report a 30-year-old male patient with traumatic renal artery dissection, who was successfully treated by stent-graft placement using the triaxial system.
format Online
Article
Text
id pubmed-7753229
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-77532292020-12-23 Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report Okabe, Haruka Suzuki, Kazushi Tsukahara, Satoshi Kagaya, Risa Kitase, Masanori Mizutani, Masaru Shimohira, Masashi Shibamoto, Yuta Radiol Case Rep Case Report Stent-graft placement is an important treatment for traumatic renal artery dissection, but it may occasionally be technically difficult to advance a catheter through the lesion of the dissection due to severe stenosis of the true rumen. A triple-coaxial (triaxial) system, which consists of a small microcatheter, a large microcatheter, and a 4-Fr. catheter, has recently become available, and it contributes to super-selective catheterization. We thought this system may be useful for passing catheters through the dissection. We herein report a 30-year-old male patient with traumatic renal artery dissection, who was successfully treated by stent-graft placement using the triaxial system. Elsevier 2020-12-18 /pmc/articles/PMC7753229/ /pubmed/33363689 http://dx.doi.org/10.1016/j.radcr.2020.12.032 Text en © 2020 Published by Elsevier Inc. on behalf of University of Washington. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Okabe, Haruka
Suzuki, Kazushi
Tsukahara, Satoshi
Kagaya, Risa
Kitase, Masanori
Mizutani, Masaru
Shimohira, Masashi
Shibamoto, Yuta
Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report
title Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report
title_full Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report
title_fullStr Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report
title_full_unstemmed Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report
title_short Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report
title_sort triaxial system in stent-graft placement for traumatic renal artery dissection: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7753229/
https://www.ncbi.nlm.nih.gov/pubmed/33363689
http://dx.doi.org/10.1016/j.radcr.2020.12.032
work_keys_str_mv AT okabeharuka triaxialsysteminstentgraftplacementfortraumaticrenalarterydissectionacasereport
AT suzukikazushi triaxialsysteminstentgraftplacementfortraumaticrenalarterydissectionacasereport
AT tsukaharasatoshi triaxialsysteminstentgraftplacementfortraumaticrenalarterydissectionacasereport
AT kagayarisa triaxialsysteminstentgraftplacementfortraumaticrenalarterydissectionacasereport
AT kitasemasanori triaxialsysteminstentgraftplacementfortraumaticrenalarterydissectionacasereport
AT mizutanimasaru triaxialsysteminstentgraftplacementfortraumaticrenalarterydissectionacasereport
AT shimohiramasashi triaxialsysteminstentgraftplacementfortraumaticrenalarterydissectionacasereport
AT shibamotoyuta triaxialsysteminstentgraftplacementfortraumaticrenalarterydissectionacasereport