Cargando…
High‐frequency (20 MHz) high‐intensity focused ultrasound: New ablative method for color‐independent tattoo removal in 1‐3 sessions. An open‐label exploratory study
BACKGROUND: High‐intensity focused ultrasound (HIFU) operating at 20 MHz is new and potentially applicable to ablative tattoo removal. The method was documented safe and rational in preclinical testing. MATERIALS AND METHODS: High‐intensity focused ultrasound was introduced to subjects when lasers a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754334/ https://www.ncbi.nlm.nih.gov/pubmed/32557859 http://dx.doi.org/10.1111/srt.12885 |
_version_ | 1783626170876559360 |
---|---|
author | Serup, Jørgen Bove, Torsten Zawada, Tomasz Jessen, Alexander Poli, Mattia |
author_facet | Serup, Jørgen Bove, Torsten Zawada, Tomasz Jessen, Alexander Poli, Mattia |
author_sort | Serup, Jørgen |
collection | PubMed |
description | BACKGROUND: High‐intensity focused ultrasound (HIFU) operating at 20 MHz is new and potentially applicable to ablative tattoo removal. The method was documented safe and rational in preclinical testing. MATERIALS AND METHODS: High‐intensity focused ultrasound was introduced to subjects when lasers and dermatome shaving had failed or caused side effects. Transducers with focal depths between 1.1 mm and 1.7 mm in the skin were used, and settings of 0.4‐1.2 J/shot at pulse durations of 150 ms were applied. Tattoos were covered with synergistic “shoulder‐by‐shoulder” focused ultrasound shots. Effectiveness and side effects were measured. RESULTS: Twenty‐two subjects with 67 tattoos were treated. 62% benefitted (19% cleared, 43% partially cleared), and 28% had minor effect. VAS pain was 5‐6 versus 7‐9 with previous lasers removal. Wound healing was longer after HIFU ablation (1‐3 months). 57% of subjects had no scar or minor visible changes of skin surface markings only, while 19% had moderate or major skin thickening. Hypertrophic scar or keloid scars were not observed. DISCUSSION/CONCLUSION: High‐intensity focused ultrasound was effective in removal of difficult tattoos of any color where Nd:YAG lasers had failed. The method only needs 1‐3 sessions. As an ablative method, the wound healing period is longer than with laser removal and needs attention. Focused ultrasound can be used as a first‐line treatment of smaller tattoos independent of color, and second line when Nd:YAG lasers have failed or caused problems. The operator shall be qualified, as with lasers. |
format | Online Article Text |
id | pubmed-7754334 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77543342020-12-23 High‐frequency (20 MHz) high‐intensity focused ultrasound: New ablative method for color‐independent tattoo removal in 1‐3 sessions. An open‐label exploratory study Serup, Jørgen Bove, Torsten Zawada, Tomasz Jessen, Alexander Poli, Mattia Skin Res Technol Original Articles BACKGROUND: High‐intensity focused ultrasound (HIFU) operating at 20 MHz is new and potentially applicable to ablative tattoo removal. The method was documented safe and rational in preclinical testing. MATERIALS AND METHODS: High‐intensity focused ultrasound was introduced to subjects when lasers and dermatome shaving had failed or caused side effects. Transducers with focal depths between 1.1 mm and 1.7 mm in the skin were used, and settings of 0.4‐1.2 J/shot at pulse durations of 150 ms were applied. Tattoos were covered with synergistic “shoulder‐by‐shoulder” focused ultrasound shots. Effectiveness and side effects were measured. RESULTS: Twenty‐two subjects with 67 tattoos were treated. 62% benefitted (19% cleared, 43% partially cleared), and 28% had minor effect. VAS pain was 5‐6 versus 7‐9 with previous lasers removal. Wound healing was longer after HIFU ablation (1‐3 months). 57% of subjects had no scar or minor visible changes of skin surface markings only, while 19% had moderate or major skin thickening. Hypertrophic scar or keloid scars were not observed. DISCUSSION/CONCLUSION: High‐intensity focused ultrasound was effective in removal of difficult tattoos of any color where Nd:YAG lasers had failed. The method only needs 1‐3 sessions. As an ablative method, the wound healing period is longer than with laser removal and needs attention. Focused ultrasound can be used as a first‐line treatment of smaller tattoos independent of color, and second line when Nd:YAG lasers have failed or caused problems. The operator shall be qualified, as with lasers. John Wiley and Sons Inc. 2020-06-18 2020-11 /pmc/articles/PMC7754334/ /pubmed/32557859 http://dx.doi.org/10.1111/srt.12885 Text en © 2020 TOOsonix A/S. Skin Research and Technology published by John Wiley & Sons Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Serup, Jørgen Bove, Torsten Zawada, Tomasz Jessen, Alexander Poli, Mattia High‐frequency (20 MHz) high‐intensity focused ultrasound: New ablative method for color‐independent tattoo removal in 1‐3 sessions. An open‐label exploratory study |
title | High‐frequency (20 MHz) high‐intensity focused ultrasound: New ablative method for color‐independent tattoo removal in 1‐3 sessions. An open‐label exploratory study |
title_full | High‐frequency (20 MHz) high‐intensity focused ultrasound: New ablative method for color‐independent tattoo removal in 1‐3 sessions. An open‐label exploratory study |
title_fullStr | High‐frequency (20 MHz) high‐intensity focused ultrasound: New ablative method for color‐independent tattoo removal in 1‐3 sessions. An open‐label exploratory study |
title_full_unstemmed | High‐frequency (20 MHz) high‐intensity focused ultrasound: New ablative method for color‐independent tattoo removal in 1‐3 sessions. An open‐label exploratory study |
title_short | High‐frequency (20 MHz) high‐intensity focused ultrasound: New ablative method for color‐independent tattoo removal in 1‐3 sessions. An open‐label exploratory study |
title_sort | high‐frequency (20 mhz) high‐intensity focused ultrasound: new ablative method for color‐independent tattoo removal in 1‐3 sessions. an open‐label exploratory study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754334/ https://www.ncbi.nlm.nih.gov/pubmed/32557859 http://dx.doi.org/10.1111/srt.12885 |
work_keys_str_mv | AT serupjørgen highfrequency20mhzhighintensityfocusedultrasoundnewablativemethodforcolorindependenttattooremovalin13sessionsanopenlabelexploratorystudy AT bovetorsten highfrequency20mhzhighintensityfocusedultrasoundnewablativemethodforcolorindependenttattooremovalin13sessionsanopenlabelexploratorystudy AT zawadatomasz highfrequency20mhzhighintensityfocusedultrasoundnewablativemethodforcolorindependenttattooremovalin13sessionsanopenlabelexploratorystudy AT jessenalexander highfrequency20mhzhighintensityfocusedultrasoundnewablativemethodforcolorindependenttattooremovalin13sessionsanopenlabelexploratorystudy AT polimattia highfrequency20mhzhighintensityfocusedultrasoundnewablativemethodforcolorindependenttattooremovalin13sessionsanopenlabelexploratorystudy |