Cargando…
High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model
PURPOSE: To compare the biomechanical properties of high-tensile strength tape and a high-tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model. METHODS: A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754602/ https://www.ncbi.nlm.nih.gov/pubmed/33376994 http://dx.doi.org/10.1016/j.asmr.2020.07.018 |
Sumario: | PURPOSE: To compare the biomechanical properties of high-tensile strength tape and a high-tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model. METHODS: A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus tendons were used. Two types of suture materials, high-tensile strength sutures (group S) and high-tensile strength tapes (group T), were evaluated. After we inserted metallic suture anchors with either 2 sutures or tapes 5 cm from the superomedial corner of the greater tuberosity, a Krackow suture technique was used to secure the tendons. After a preload of 5 N for 2 minutes, a cyclic loading test from 5 to 70 N was conducted for 500 cycles. Finally, the specimen was loaded to failure at a rate of 1 mm/s. RESULTS: There were no significant between-group differences in elongation after cyclic loading and elongation at failure load for group S and group T (P = .977 and .630, respectively). The ultimate failure loads in group T (278.2 ± 54 N) were significantly greater than those in group S (249.4 ± 32 N) (P = .028). In contrast, the stiffness values in group T (28.5 ± 4.0 N/mm) were significantly lower than those in group S (32.3 ± 4.5 N) (P = .028). Ten specimens in group S and 8 specimens in group T failed, with tendons being cut through by the sutures, whereas the other 2 specimens in group S and 4 specimens in group T failed due to suture breakage. CONCLUSIONS: Using high-tensile strength tapes in subpectoral biceps tenodesis using a suture anchor leads to significantly greater ultimate failure load as compared with using high-tensile strength sutures in a porcine model. Although lower levels of stiffness were found in high-tensile strength tape group, the difference in the means were not large between 2 groups. CLINICAL RELEVANCE: A strong suture–tendon structure may prevent clinical failure of a subpectoral biceps tenodesis using a suture anchor. |
---|